• Title/Summary/Keyword: Dose Sensitivity

Search Result 477, Processing Time 0.022 seconds

Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis (디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.541-547
    • /
    • 2018
  • To evaluate the effect of dose and image quality for Chest Digital Tomosynthesis(CDT) using sensitivity and tube voltage(kV). CDT images of the phantom were acquired varying sensitivity 200, 320, 400 according to set tube voltage of 125 kV and 135 kV. The dose and Dose Area Product(DAP) according to change of sensitivity and kV were evaluated and Image quality was evaluated by PSNR, CNR, SNR using Image J. Dose were lowered 14~23% less than sensitivity 200, 125 kV and DAP were lowered 13~26% less than sensitivity 200, 125 kV. PSNR were over 27 dB, which were significant value and CNR, SNR were better as sensitivity value was lower. But there were different statistical significant to each item. CNR and SNR were not statistically significant at sensitivity 320, 135 kV(P>0.05). CDT can improve image quality with lower radiation dose using better than quality and correction power at digital radiography system.

Effect of Chromium Picolinate on Glucose Tolerance and Insulin Sensitivity in the Type I and II Diabetic Rats (1형과 2형 당뇨모델 흰쥐에서 Chromium Picolinate의 당내성과 인슬린 감수성에 대한 영향)

  • 신현진;홍정희;고현철;신인철;강주섭;최호순;김태화;김동선;엄애선
    • Biomolecules & Therapeutics
    • /
    • v.9 no.4
    • /
    • pp.277-281
    • /
    • 2001
  • Chromium is an essential nutrient and participates in glucose and lipid metabolism in human beings and animals. The present study was conducted to assess the effects of chromium picolinate (Cr-pic) on glucose tolerance and insulin sensitivity in type I and ll diabetic rats. The experimental groups were type I diabetic (streptozotocin-induced: 40 mg/kg, i.p.) and type II diabetic (Goto-Kakizaki rats) models. Each group was subdivided into control. low-dose and high-dose of Cr-pic treated groups. The Cr-pic was orally administered with Cr-pic (100 mg/kg for low dose group and 200 mg/kg for high dose group) for 4 weeks. And then we performed intraperitoneal glucose tolerance test (IPGTT) and insulin sensitivity test (ITT). The glucose tolerance test was carried out by inection of glucose (2 g/kg, i.p.). The peripheral insulin sensitivity test was con- ducted by injection of insulin (5 units/kg, s.c.) and glucose. We performed determining of blood glucose concentration at 0, 10, 30, 60, 90, and 120 min using automated glucose analyzer. The plasma insulin concentration was determined by rat insulin EIA kit. Administration of Cr-pic improved weight gain in all group s with higher significant in the low-dose group. There was no significance between the control and the Cr-pic treated groups in the area under the blood glucose curve and serum insulin concentration plots of IPGTT and peripheral ITT in type I diabetic rats. But Cr-pic treated groups showed significantly lower levels of the area under the blood glucose currie during IPGTT and ITT and the high-dose group showed less effects compared with the low-dose group in the type II diabetic rats. The plasma insulin concentration of both diabetic groups was not influenced by Cr-pic supplementation. We can conclude that chromium picolinate may improve the endogenous and exogenous insulin action and peripheral insulin sensitivity in type II diabetic rats.

  • PDF

Changes of Optically Stimulated Luminescence Dosimeter Sensitivity with High Dose (고선량에 대한 광자극발광선량계의 방사선 민감도 변화 연구)

  • Han, Su Chul;Kim, Kum Bae;Choi, Sang Hyoun;Park, Seungwoo;Jung, Haijo;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.98-104
    • /
    • 2016
  • We investigated the effect of high dose on the sensitivity of optically stimulated luminance dosimeters (OSLDs) on Co-60 gamma rays and used a commercial OLSD (Landauer, Inc., Glenwood, IL). New OSLDs were chosen arbitrarily and were irradiated with 1 Gy repeatedly. We confirmed the change in the radiation sensitivity after repeated irradiation. The OSLD sensitivity increased up to 3% after irradiating for seven times and decreased continuously after the eighth time. It dropped by approximately 0.35 Gy per irradiation. Finally, after irradiating for 30 times, the OSLD sensitivity decreased by approximately 7%. When the OSLDs were irradiated 10 times with 1 Gy after their irradiation using a high dose of 15 Gy and 30 Gy, their sensitivity decreased by 6% and 12%, respectively, compared to that before high-dose irradiation. The change in the OSLD sensitivity with a high dose could be modeled by an exponential equation. We confirmed the radiation sensitivity variation caused by a high dose, and the irradiation history of dosimeters was considered to reuse OSLDs irradiated with a high dose.

A Study on the Quantitative Analysis Method through the Absorbed Dose and the Histogram in the Performance Evaluation of the Detector according to the Sensitivity Change of Auto Exposure Control(AEC) in DR(Digital Radiography) (DR(Digital Radiography)에서 자동노출제어장치의 감도변화에 따른 검출기 성능평가 시 흡수선량과 히스토그램을 통한 정량적 분석방법에 관한 연구)

  • Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.232-240
    • /
    • 2018
  • This study is to suggest a method to evaluate the detector performance using change of absorbed dose and histogram according to sensitivity change of Auto Exposure Control(AEC). The experiment site is skull, abdomen pelvis and the accuracy of the detector was evaluated by measuring the absorbed dose of the detector sensitivity S200, S400, S800, S1000. Also the dynamic range of the detector was evaluated through the histogram analysis. As a result, the absorbed dose decreased gradually as the sensitivity was set higher from S200 to S1000. And through the sensitivity histogram analysis, as the sensitivity of the skull is set higher, the amount of information at both ends of the histogram is lost. Abdomen and pelvis areas showed underflow phenomena in which the amount of information in the first part of the histogram was lost as the sensitivity was set higher. In conclusion, the detector accurately implemented the sensitivity change, but the dynamic range of the image due to the sensitivity change of the AEC due to the deterioration of the detector performance can not be realized properly and it was found that the evaluation through the absorbed dose and the histogram is useful when evaluating the performance of the detector.

A Study on Dose Sensitivity according to Position Variance in Extremities Radiation Therapy with Water Bolus (사지의 방사선 치료에 사용하는 water bolus의 적용 시 치료부위의 위치 변화에 따른 방사선 선량분포의 민감도 연구)

  • Seo, Jeong Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.199-206
    • /
    • 2015
  • The purpose of this study was to investigate radiation dose sensitivity due to displacement of human extremities in the water bolus box on radiation therapy. Water bolus box and human thigh with femur bone were constructed in computerized radiation therapy planning system to verify the absorbed dose. Two 6MV X-ray beams were irradiated bilaterally into water bolus box and then radiation dose were calculated each situation at displacement of middle axis of thigh from the center in water bolus box to right and left direction. Absorbed dose of thigh and femur bone increased by the distance of displacement. The maximum dose of thigh even increased 20% over than prescribed dose. This is in contrast to conventional concept of dose distribution in water bolus box. Based on this result, displacement of body site in the water bolus box have to be averted during radiation therapy.

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

Important Radionuclides and Their Sensitivity for Ground water Pathway of a Hypothetical Near-Surface Disposal Facility

  • Park, J. W.;K. Chang;Kim, C. L.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.156-165
    • /
    • 2001
  • A radiological safety assessment was performed for a hypothetical near-surface radioactive waste repository as a simple screening calculation to identify important nuclides and to provide insights on the data needs for a successful demonstration of compliance. Individual effective doses were calculated for a conservative ground water pathway scenario considering well drilling near the site boundary. Sensitivity of resulting ingestion dose to input parameter values was also analyzed using Monte Carlo sampling. Considering peak dose rate and assessment time scale, C-14 and T-129 were identified as important nuclides and U-235 and U-238 as potentially important nuclides. For C-14, the dose was most sensitive to Darcy velocity in aquifer The distribution coefficient showed high degree of sensitivity for I-129 release.

  • PDF

Sensitivity Variations with pre-irradiation dose to P-type Semi conductor for radiation dosimetry

  • 최태진;김옥배
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.49-57
    • /
    • 1995
  • The semiconductor detector has a high sensitive to radiation and a small volume. It has been frequently used in high energy photon and electron beamdosimetry. However, Semiconductor detector are subject to radiation damage in high energy radiation beam which reduces the sensitivity and creat a large discrepancy. In this experiments, P-type semiconductor was irradiated to 18 MeV electron beam with pre-irradiation for reducing the sensitivity for high reproducibility and investigated the dose characteristics against the dose rate variations. The sensitivity per unit dose in small dose rate showed a 35% large different to a large dose rate with pre-irradiation dose for 0.5 KGy and 20% for 3 KGyin this study. The silicon detector has showed a large dependency of beam direction with 13% discrepancy and a linear sensitive as increased temperature.

  • PDF

Analysis of Physical Properties for Various Compositions of Reusable LMG and LCV Micelle Gel

  • Kang, Jin Mook;Lee, Dong Han;Cho, Yu Ra;Hwang, Seon Bung;Ji, Young Hoon;Ahn, So Hyun;Keum, Ki Chang;Lee, Re Na;Cho, Sam Ju;Noh, Insup
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.175-179
    • /
    • 2016
  • In this study, we evaluated the reusable leuco malachite green (LMG) micelle gel properties dependent on various components of chemical concentration and compared with leuco crystal violet (LCV). The gels were delivered to 10, 20, 30, 40 and 50 Gy at 6 MV photon beam from linear accelerator and analyzed using spectrophotometry. We confirmed that the reusable LMG and LVC absorbance wavelength peak were made up at 630 nm and 600 nm respectively. The transparency of reusable LMG decreased with higher amount of trichloroacetic acid (TCAA) and lower reusable LMG dyes. 1 mM reusable LMG was the lowest transparency. The sensitivity was increased depending on lower trichloroacetic acid (TCAA) concentrations and the amount of suitable surfactant (Triton X-100), which was found to be 7 mM. However, we were not able to investigate sensitivity effects factor from reusable LMG dyes. The gel dosimeter containing 16 mM TCAA, 7 mM Triton X-100 gel dosimeter showed the highest sensitivity at $0.0021{\pm}0.0001cm^{-1}.Gy^{-1}$. The sensitivity of LCV was found to be higher than reusable LMG at $0.0037{\pm}0.0005cm^{-1}.Gy^{-1}$. The reusable LMG and LCV dose responses were shown to be $R^2=0.997$, $R^2=0.999$ respectively, as stable measurement results. Future research is necessary to improve dose sensitivity, dose rate dependency and gel fading with extensive chemical formulations.

Isolation and Characterization of DNA Damaging Agent Sensitivity of rqh1 mutant from Schizosaccharomyce pombe (분열형 효모인 Schizosaccharomyces pombe 로부터 rqh1 돌연변이의 DNA damaging agent sensitivity를 보상하는 유전자의 특성 연구)

  • Lee, In-Hye;Choi, In-Soon
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.39-44
    • /
    • 2007
  • The Rqh1 gene is essential for vegetative growth in fission Yeast. The rqh1 mutant showed that sensitivity of DNA damaging agent, a wild range of phenotype including abnormal gene expression and cell elongation. This result showed that the rqhl-overexpression cell was sensitivity to DNA damaging agent like rqhl mutant. When Rqh1 have an over-expression by $nmt1^+$ promoter of pREP vector, rqh1 mutant DNA damaging agent sensitivity could be compensated. We isolated two strong mutant containing complementation gene, rqh156 and rqh172, respectively. This result observed that the DNA damaging agent sensitivity of rqhl mutant was complemented by the expression of rqh156 and rqh172. They induced mRNA expression in a dose-dependent manner HU, MMS and UV. The HU sensitivity of the rqhl was complemented by the expression of rqh156 and rqh172. The mRNA expression of rqh156 decreased on HU dose dependent but the mRNA expression of rqh172 did not decrease on HU dose dependent. The MMS and W sensitivity of the rqhl was complemented by the expression of rqh156 and rqh172. These results indicate that the isolated rqhl gene may play an important role in DNA metabolism.