• 제목/요약/키워드: Dose Reduction

검색결과 1,484건 처리시간 0.027초

Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters (라돈 환경계통의 제어 매개변수 모델링)

  • Zoo, Oon-Pyo;Kim, Kem-Joong;Chang, Si-Young
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

Exposure dose Reduction using Pb Banding of own manufacturing (자체제작 Pb 밴딩을 이용한 피폭선량 감소)

  • Kim, Chang-Gyu
    • Journal of Digital Convergence
    • /
    • 제11권6호
    • /
    • pp.269-273
    • /
    • 2013
  • Exposure dose to the examinee was measured using glass dosimeter in the test using panorama device at the time of dental treatment. As a result of measuring expose dose to lens according to the different sizes of Pb banding of own manufacturing to reduce exposure dose to lens especially sensitive to radiation, it was verified that exposure dose to lens varied depending on the size of the Pb banding. With the size of Pb banding of $3{\times}20{\times}0.2cm$, exposure dose tended to increase higher than normal value, and with the size of or more than $5{\times}20{\times}0.2cm$, it decreased. And also, the obtained image with the size of $7{\times}20{\times}0.2cm$ was not suitable for diagnosis. Therefore, it is expected that exposure dose would be reduced by using Pb banding of the size of not less than $5{\times}20{\times}0.2cm$ and not more than $6{\times}20{\times}0.2cm$ in the test, to minimize exposure dose and conduct panorama test efficiently.

Effects of Exposure to Estradiol Benzoate or Flutamide at the Weaning Age on Expression of Connexins in the Caudal Epididymis of Adult Rat

  • Lee, Ki-Ho
    • Development and Reproduction
    • /
    • 제20권4호
    • /
    • pp.349-357
    • /
    • 2016
  • The present research was chiefly designed to determine the effect of the treatment of estrogenic agonist, estradiol benzoate (EB), or antiandrogenic compound, flutamide (Flu), at the weaning age on the expression of connexin (Cx) isoforms in the caudal epididymis of adult male rat. Animals were subcutaneously administrated with a single shot of either EB at a low-dose ($0.015{\mu}g$ of EB/kg body weight (BW)) or a high-dose ($1.5{\mu}g$ of EB/kg BW) or Flu at a low-dose ($500{\mu}g$ of EB/kg BW) or a high-dose (5 mg of EB/kg BW). Expressional changes of Cx isoforms in the adult caudal epididymis were examined by quantitative real-time PCR analysis. The treatment of a low-dose EB caused significant increases of Cx30.3, Cx31, Cx32, and Cx43 transcript levels but reduction of Cx31.1, Cx37, and Cx45 expression. Exposure to a high-dose EB resulted in very close responses observed in a low-dose EB treatment, except no significant expressional change of Cx37 and a significant induction of Cx40. Expression of all Cx isoforms, except Cx45, was significantly increased by a low-dose Flu treatment. Expressional increases of all Cx isoforms were detected by a high-dose Flu treatment. The current study demonstrates that a single exposure to estrogenic or antiandrogenic compound during the early postnatal developmental period is sufficient to disrupt normal expression of Cx isoforms in the adult caudal epididymis.

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • 제32권3호
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • 제39권3호
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • 제6권6호
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

Feasibility of Shrinking Field Radiation Therapy through 18F-FDG PET/CT after 40 Gy for Stage III Non-Small Cell Lung Cancers

  • Ding, Xiu-Ping;Zhang, Jian;Li, Bao-Sheng;Li, Hong-Sheng;Wang, Zhong-Tang;Yi, Yan;Sun, Hong-Fu;Wang, Dong-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권1호
    • /
    • pp.319-323
    • /
    • 2012
  • Objective: To explore the feasibility of shrinking field technique after 40 Gy radiation through 18F-FDG PET/CT during treatment for patients with stage III non-small cell lung cancer (NSCLC). Methods: In 66 consecutive patients with local-advanced NSCLC, 18F-FDG PET/CT scanning was performed prior to treatment and repeated after 40 Gy. Conventionally fractionated IMRT or CRT plans to a median total dose of 66Gy (range, 60-78Gy) were generated. The target volumes were delineated in composite images of CT and PET. Plan 1 was designed for 40 Gy to the initial planning target volume (PTV) with a subsequent 20-28 Gy-boost to the shrunken PTV. Plan 2 was delivering the same dose to the initial PTV without shrinking field. Accumulated doses of normal tissues were calculated using deformable image registration during the treatment course. Results: The median GTV and PTV reduction were 35% and 30% after 40 Gy treatment. Target volume reduction was correlated with chemotherapy and sex. In plan 2, delivering the same dose to the initial PTV could have only been achieved in 10 (15.2%) patients. Significant differences (p<0.05) were observed regarding doses to the lung, spinal cord, esophagus and heart. Conclusions: Radiotherapy adaptive to tumor shrinkage determined by repeated 18F-FDG PET/CT after 40 Gy during treatment course might be feasible to spare more normal tissues, and has the potential to allow dose escalation and increased local control.

Synergistic Effect of Ethaselen and Selenite Treatment against A549 Human Non-small Cell Lung Cancer Cells

  • Xu, Wei;Ma, Wei-Wei;Zeng, Hui-Hui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7129-7135
    • /
    • 2014
  • Background: In this study, we aimed to evaluate the growth inhibitory effect of the combination of ethaselen (BBSKE) and low fixed dose of selenite against A549 human non-small cell lung cancer cells in vitro. Materials and Methods: Growth inhibitory effects against A549 cells were determined by SRB assay. Combination index (CI) values were calculated based on Chou-Talalay median-effect analyses. Dose reduction index (DRI) values were applied to calculate dose reduction of selenite. Contents of free thiols and GSH were determined by DTNB assay and intracellular ROS levels by DCFH-DA fluorescence labeling. Results: Compared with BBSKE or selenite single treatment, the combined application of ethaselen and a low fixed dose of selenite shortened the onset time of sodium selenite, reduced $IC_{50}$ values, and increased the maximum inhibition rates, suggesting a possible molecular mechanism of the synergism. Obvious synergistic effects were observed after different times of combination treatment, especially after 24 h. Compared with selenite single treatment, dosage of selenite could be remarkably reduced in combination therapy to gain the same inhibitory effect on cell proliferation. Compared with BBSKE single treatment, the content of free thiols and GSH were significantly reduced and ROS levels greatly elevated in the combination group. For the combination treatment, cell viability increased as greater concentrations of GSH were added. Conclusions: All these results indicate that the combination treatment of BBSKE and selenite showed synergism to inhibit A549 cell proliferation in vitro, and also reduced the selenite dosage to mitigate its toxicity which is very meaningful for combination chemotherapy of lung cancer. The synergism was probably caused by the accelerated exhaustion of intracellular reductive substances, such as free thiols and GSH, which ultimately leads to enhanced oxidative stress and apoptosis.

Radiation Sensitivity of Some Toxigenic Molds Isolated from Deteriorated Rice (변질미(變質米)에서 분리된 독소생성(毒素生成)곰팡이의 방사선(放射線) 감수성(感受性))

  • Choi, Eon-Ho;Kim, Hong-Lyour;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • 제7권3호
    • /
    • pp.148-153
    • /
    • 1975
  • Seven toxigenic molds isolated from deteriorated rice in Korea, Aspergillus clavatus, Asp. flavus var. columnaris, Asp. fumigatus, Asp. ochraceus, Penicillium citrinum, Pen. implicatum, and Pen. islandicum, were examined for their sensitivity toward Co-60 gamma rays for survival. Conidia of all tested species showed survival curves of sigmoidal type, from which decimal reduction doses were found to vary in the range of $14{\sim}33$ krad, induction doses, in the range of $12{\sim}56$ krad and inactivation factors at 200 krad, in the range of $4.6{\sim}12.8$, all at a dose rate of 11.56 krad/min. Dose rate effects on the radiosensitivity of Asp. flavus and Pen. islandicum conidia indicated that the higher dose rate (11.56 krad/min) caused decreases in decimal reduction doses as compared with the lower dose rate (2.67 krad/min).

  • PDF

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • 제44권1호
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.