• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.038 seconds

Reference levels for patient Radiation Dose in interventional radiological procedures (중재적 방사선 시술 시 환자선량에 대한 참고 준위 비교)

  • Park, Hyeok;Kim, Yong-Wan;Jeon, Ju-Seob
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2012
  • The purpose of this study is to measure and evaluate radiation dose on patients in interventional radiological(IVR) procedures classified by each procedure, and aid as data for safety management. Fluroscopy time(F-time), dose area product(DAP) and number of acquired images from each kind of procedure was checked. Non-vascular procedures showed low value, and vascular procedure showed high value in all procedures except in IVC filter. F-time was longest in EVAR, which showed also the highest DAP value of all procedures. DAP-rate showed high value in TACE. By this result, we attempt to establish standard guideline of radiation dose on patients in IVR procedure.

Effects of Mori Folium Ethanol Soluble Fraction on mRNA Expression of glucose transporters, acetyl-CoA carboxylase and leptin (상엽 에탄올가용분획의 글루코스전달체, acetyl-CoA 카복시라제 및 렙틴 mRNA 발현에 미치는 영향)

  • Ryu, Jeong-Wha;Yook, Chang-Soo;Chung, Sung-Hyun
    • YAKHAK HOEJI
    • /
    • v.42 no.6
    • /
    • pp.589-597
    • /
    • 1998
  • Effects of Mori Folium Ethanol Soluble Fraction (MFESF) on mRNA expression of glucose transporters, acetyl-CoA carboxylase (ACC) and leptin were examined in db/db mice. 500 and 1000mg/kg dose for MFESF (designated by SY 500 and SY 1000, respectively) and 5mg/kg dose for acarbose were administered for 6 weeks. Quantitations of glucose transporters (GLUT-2 and GLUT-4), ACC and leptin mRNA were performed by RT-PCR and in vitro transcription with co-amplification of rat ${\beta}$-actin gene as an internal standard. Muscular GLUT-4 mRNA expression in MFESF-treated groups were increased dose dependently. On the other hand, MFESF caused the GLLT-4 and leptin mRNA expressions in adipose tissue to decrease dose dependently, which means that triglyceride synthesis in adipocytes might be decreased and consequently signals adipocytes to inhibit the synthesis and release of leptin. Hepatic ACC mRNA expression in MFESF-treated groups was also decreased. and this may result in lowering of serum triiglyceride level. In contrast, liver GLUT-2 mRNA expressions in MFESF-treated and acarbose groups were increased. Higher rate of glucose uptake into hepatocytes is known to inhibit a phosphoenolpyruvate carboxykinase (PEPCK)-catalyzed reaction, which is a rate-limiting step in gluconeogenesis.

  • PDF

Forbush Decreases Observed by the LRO/CRaTER

  • Sohn, Jongdae;Oh, Suyeon;Yi, Yu;Kim, Eojin;Lee, Joo-Hee;Spence, Harlan E.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.120.1-120.1
    • /
    • 2012
  • The Lunar Reconnaissance Orbiter (LRO) launched on June 16, 2009 has six experiments including of the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) onboard. The CRaTER instrument characterizes the radiation environment to be experienced by humans during future lunar missions. The CRaTER instrument measures the effects of ionizing energy loss in matter specifically in silicon solid-state detectors due to penetrating solar energetic protons (SEP) and galactic cosmic rays (GCRs) after interactions with tissue-equivalent plastic (TEP), a synthetic analog of human tissue. The CRaTER instrument houses a compact and highly precise microdosimeter. It measures dose rates below one micro-Rad/sec in silicon in lunar radiation environment. Forbush decrease (FD) event is the sudden decrease of GCR flux. We use the data of cosmic ray and dose rates observed by the CRaTER instrument. We also use the CME list of STEREO SECCHI inner, outer coronagraph and the interplanetary CME data of the ACE/MAG instrument.We examine the origins and the characteristics of the FD-like events in lunar radiation environment. We also compare these events with the FD events on the Earth. We find that whenever the FD events are recorded at ground Neutron Monitor stations, the FD-like events also occur on the lunar environments. The flux variation amplitude of FD-like events on the Moon is approximately two times larger than that of FD events on the Earth. We compare time profiles of GCR flux with of the dose rate of FD-like events in the lunar environment. We figure out that the distinct FD-like events correspond to dose rate events in the CRaTER on lunar environment during the event period.

  • PDF

Low-dose intravenous ketamine versus intravenous ketorolac in pain control in patients with acute renal colic in an emergency setting: a double-blind randomized clinical trial

  • Sotoodehnia, Mehran;Farmahini-Farahani, Mozhgan;Safaie, Arash;Rasooli, Fatemeh;Baratloo, Alireza
    • The Korean Journal of Pain
    • /
    • v.32 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • Background: This study was conducted to compare the effectiveness of low-dose ketamine versus ketorolac in pain control in patients with acute renal colic presenting to the emergency department (ED). Methods: This is a double-blind randomized clinical trial. The initial pain severity was assessed using the numerical rating scale (NRS). Then, ketamine or ketorolac was administered intravenously at a dose of 0.6 mg/kg and 30 mg respectively. The pain severity and adverse drug reactions were recorded 5, 15, 30, 60, and 120 min thereafter. Results: The data of 62 subjects in the ketamine group and 64 patients in the ketorolac group were analyzed. The mean age of the patients was $34.2{\pm}9.9$ and $37.9{\pm}10.6\;years$ in the ketamine and ketorolac group, respectively. There was no significant difference in the mean NRS scores at each time point, except for the 5 min, between the two groups. Despite a marked decrease in pain severity in the ketamine group from drug administration at the 5 min, a slight increase in pain was observed from the 5 min to the 15 min. The rate of adverse drug reactions, including dizziness (P = 0.001), agitation (P = 0.002), increased systolic blood pressure (> 140 mmHg), and diastolic blood pressure (> 90 mmHg) was higher in the ketamine group. Conclusions: Low dose ketamine is as effective as ketorolac in pain management in patients with renal colic presenting to the ED. However, it is associated with a higher rate of adverse drug reactions.

Preoperative Corticosteroid Use and Early Postoperative Bronchial Anastomotic Complications after Lung Transplantation

  • Kim, Ha Eun;Paik, Hyo Chae;Kim, Song Yee;Park, Moo Suk;Lee, Jin Gu
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.384-389
    • /
    • 2018
  • Background: Airway anastomotic complications are a leading cause of mortality after lung transplantation. Among the factors that cause airway complications, preoperative steroid use has been considered to be related with postoperative airway healing. We analyzed the influence of preoperative steroid use on postoperative airway complications. Methods: The medical records of 66 double-lung transplant recipients from January 2014 to December 2015 were reviewed. Forty patients were prescribed steroids preoperatively. The daily steroid dose was standardized using the patient's body mass index (BMI). Patients who received preoperative steroids were sub-divided into high-dose (HD) and low-dose (LD) groups (cut-off value, 1.6 mg/BMI/day). Results: Thirteen patients suffered from airway complications postoperatively (bronchopulmonary fistula, 9; bronchial stenosis, 4). There was a tendency for early development of airway complications in the steroid use group compared to the non-steroid use group, but it was not significant (percentage free from airway complications in year 1: non-steroid group, 90.9% vs. steroid group, 79.2%; p=0.43). The percentage of patients in the LD and HD groups who were free from airway complications in year 1 was not significantly different (84.0% vs. 77.8%, p=0.39). Conclusion: The airway complication rate did not vary significantly according to steroid use. Additionally, in patients who received preoperative steroids, the dose did not affect the rate of development of airway complications.

In Vitro Experiment to Evaluate 137Cs Dissolution in the Digestion Process of Mushrooms

  • Nishiono, Kanoko;Yamanishi, Hirokuni
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.154-162
    • /
    • 2020
  • Background: Several studies have reported that wild mushrooms contain high amounts of radioactive cesium (137Cs). After the Fukushima Daiichi Nuclear Power Plant Accident, a significantly high concentration of 137Cs has been detected in wild mushrooms, and their consumption may be the cause of the chronic internal exposure of local consumers to radioactivity. Therefore, an accurate evaluation of the internal radioactivity resulting from mushroom ingestion is needed. Materials and Methods: The 137Cs elution rate through the cooking and digestion stages was evaluated using in vitro experiments. The edible mushroom Pleurotus djamor was taken as a sample for the experiments. The mushrooms were cultivated onto solid media containing 137Cs. We evaluated the internal dose based on the actual conditions using the elution rate data. For various cooking methods, the results were compared with those of other wild edible mushrooms. Results and Discussion: From the elution experiment through cooking, we proved that 25%-55% of the 137Cs in the mushrooms was released during soaking, boiling, or frying. The results of a simulated digestion experiment after cooking revealed that almost all the 137Cs in the ingested mushrooms eluted in the digestive juice, regardless of the cooking method. The committed effective dose was reduced by 20%-75% when considering the dissolution through the cooking process. Conclusion: We found that cooking lowers 137Cs concentration in mushrooms, therefore reducing the amount of radioactivity intake. Besides, since there were differences between mushroom types, we demonstrated that the internal exposure dose should be evaluated in detail considering the release of 137Cs during the cooking stages.

Preliminary Test of 3D Printed Plastic Scintillators for Proton Beam (3D 프린팅 플라스틱 섬광체의 양성자 빔에 대한 적용)

  • Sung-Hwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.681-686
    • /
    • 2022
  • In this study, a scintillation resin for 3D printing was fabricated with 1.0 wt% of PPO organic scintillator, 5.0 wt% of MMA, and commercial acrylic resin. Using the scintillation resin, 3D-shaped plastic scintillator radiation sensors were successfully fabricated quickly and inexpensively with a commercial 3D DLP printer. The 3D printed plastic scintillator has a good dose-output linearity of R-square 0.998 was obtained in the range of 1 to 10 nA of beam current of the 45 MeV proton beam. The developed 3D plastic scintillator has low light output, so there is a limit to its use in low-dose-rate gamma-ray or X-ray dosimetry. However, it was confirmed that the tissue equivalent material could be usefully used for measuring high energy or high dose rates radiation, such as proton beams and ultra-high dose rate beams.

Seroprevalence of Measles Antibody and its Attributable Factors in Elementary Students of Routine 2-dose Schedule Era with Vaccination Record (예방접종력이 있는 초등학생의 홍역 항체 양성률 및 기여 요인)

  • Lim, Hyun-Sul;Goh, Un-Yeong;Yang, Byung-Guk;Kim, Young-Taek;Lee, Jong-Koo;Bae, Geun-Ryang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.4
    • /
    • pp.431-436
    • /
    • 2005
  • Objectives : We investigated the seroprevalence of the measles antibody and its at tributable factors for the students who underwent routine 2-dose Schedule Era. Methods : The subjects were 996 students of the national measles seroepidemiologic study in December 2000 who had vaccination records. We conducted a questionnaire survey and we performed serologic testing for the measlesspecific IgG by using an enzyme linked immunosorbent assay. Results : The coverage for the first dose of the MMR vaccination at 12-15 months of age was 95.1% and the coverage for the second dose of MMR at 4-6 years of age was 35.0%. The proportion of subjects undergoing 2-dosesof MMR dec reased as the age of the subjects increased. The seropositive rate of the measles antibody was significantly high in the second dose vaccinees (93.5% in the second dose group, 84.7% in the non-second dose group, p<0.001) and it was 72.0% in the 0-dose group, 85.4% in the 1-dose group and 93.7% in the 2-dose group (p<0.001). Two point eight percent of the subjects had a past history of measles infection. On the multiple logistic regression analysis, the first and second dose (odds ratio, 8.54; 95% CI.=3.05-23.91), the first dose (odds ratio, 3.06; 95% CI.=1.20-7.81) and the outbreak in the year 2000 (odds ratio, 1.89; 95% CI.=1.24-2.88) were the significant factors for the seropositivity. Conclusions : Maintaining high coverage with a 2-dose vaccination program would be the decisive factor to prevent an outbreak of measles and to eliminate measles in Korea.

Effect of the Space Dose Rate due to Change of X-ray Irradiation Energy and MU Value in Radiation Therapy Room (선형가속기의 엑스선 조사에너지와 MU값의 변화가 치료실 내 공간선량률 변화에 미치는 영향)

  • Kwon, Hyeonghyo;Park, Geonryul;Kim, Minji;Jo, Yeongdan;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2020
  • This study investigated the radiation protection of therapeutic radiologists. Based on the change in X-ray energy and MU value, the space dose rate in the treatment room after the irradiation was measured. 6MV, 10MV and 15MV photon beams were exposed to radiation inside the treatment room based on 300MU, 600MU and 1000MU using a linear accelerator. And repeated 10 times under the same conditions. As a result of the experiment, 0.1555 μSv/h for 6MV 300MU, 0.157 μSv /h for 300sec, 0.152 μSv/h, 0.156 μSv/h for 600MU, and 0.157 μSv/h 0.152 μSv/h for 1000MU. 300MU of 10MV was 0.49 μSv/h, 0.309 μSv/h, and 0.69 μSv/h, 0.416 μSv/h for 600MU, respectively, and 1000MU was 0.977 μSv/h and 0.478 μSv/h, respectively. The 300MU of 15MV was 3.02 μSv/h, 1.2 μSv/h, 5.459 μSv/h at 600MU, 7.34 μSv/h at 1.836 μSv/h 1000MU, and 2.709 μSv/h. The average spatial dose rate of 6MV was not significantly different from the natural spatial dose rate in the treatment room. High spatial dose rates were measured at 10 MV and 15 MV and were attenuated over time. Therefore, entering the treatment room after a certain period of time (more than 60 seconds) is considered to be effective to prevent the exposure dose of radiation workers.

Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source (Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2000
  • We designed high dose rate Ir-192 source which was prepared for substitute the Co-60 source in Ralstron unit (Simatsu, Japan) which is supplied for cervical cancer treatment. The source dimension is 1.5 mm in a diameter and 1.5mm thickness of cylinder and encapsulated with 3 mm diameter of stainless steel(SUS316L) to substituted for the Co-60 source size. The Ir-192 source was prepared the dose model for tissue dose computation through the experimental determination of apparent activity and applied the empirical tissue correction factors extended to 20cm distance. The tissue dose model was applied the 4.69 R/cm-mCi-hr gamma constant and the ratio of energy absorption coefficient of water to that of air showed 1.112 include filteration of the self-absorptions. In this experiments, we prepared the dose computation software to clinical usefulness.

  • PDF