• Title/Summary/Keyword: Dose Evaluation

Search Result 1,884, Processing Time 0.046 seconds

Production and characterization of lentivirus vector-based SARS-CoV-2 pseudoviruses with dual reporters: Evaluation of anti-SARS-CoV-2 viral effect of Korean Red Ginseng

  • Jeonghui Moon;Younghun Jung;Seokoh Moon;Jaehyeon Hwang;Soomin Kim;Mi Soo Kim;Jeong Hyeon Yoon;Kyeongwon Kim;Youngseo Park;Jae Youl Cho;Dae-Hyuk Kweon
    • Journal of Ginseng Research
    • /
    • v.47 no.1
    • /
    • pp.123-132
    • /
    • 2023
  • Background: Pseudotyped virus systems that incorporate viral proteins have been widely employed for the rapid determination of the effectiveness and neutralizing activity of drug and vaccine candidates in biosafety level 2 facilities. We report an efficient method for producing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pseudovirus with dual luciferase and fluorescent protein reporters. Moreover, using the established method, we also aimed to investigate whether Korean Red Ginseng (KRG), a valuable Korean herbal medicine, can attenuate infectivity of the pseudotyped virus. Methods: A pseudovirus of SARS-CoV-2 (SARS-2pv) was constructed and efficiently produced using lentivirus vector systems available in the public domain by the introduction of critical mutations in the cytoplasmic tail of the spike protein. KRG extract was dose-dependently treated to Calu-3 cells during SARS2-pv treatment to evaluate the protective activity against SARS-CoV-2. Results: The use of Calu-3 cells or the expression of angiotensin-converting enzyme 2 (ACE2) in HEK293T cells enabled SARS-2pv infection of host cells. Coexpression of transmembrane protease serine subtype 2 (TMPRSS2), which is the activator of spike protein, with ACE2 dramatically elevated luciferase activity, confirming the importance of the TMPRSS2-mediated pathway during SARS-CoV-2 entry. Our pseudovirus assay also revealed that KRG elicited resistance to SARS-CoV-2 infection in lung cells, suggesting its beneficial health effect. Conclusion: The method demonstrated the production of SARS-2pv for the analysis of vaccine or drug candidates. When KRG was assessed by the method, it protected host cells from coronavirus infection. Further studies will be followed for demonstrating this potential benefit.

Hair Growth Effect of TS-SCLF from Schisandra chinensis Extract Fermented with Lactobacillus plantarum

  • Young Min, Woo;Jae Yong, Seo;Soo-ya, Kim;Ji Hyun, Cha;Hyun Dae, Cho;Young Kwon, Cha;Ju Tae, Jeong;Sung Min, Park;Hwa Sun, Ryu;Jae Mun, Kim;Moon Hoy, Kim;Hee-Taek, Kim;Yong-Min, Kim;Kwang Sik, Joo;Sun Mi, Lee;JungNo, Lee;Andre, Kim
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.4
    • /
    • pp.533-547
    • /
    • 2022
  • This study investigated the hair growth effect of Schisandra chinensis extract (TS-SC) and TS-SC fermented by Lactobacillus plantarum (TS-SCLF) on human dermal papilla cells (hDPCs). The production of vascular endothelial growth factor (VEGF), insulin-like growth factor 1 (IGF-1), keratinocyte growth factor/fibroblast growth factor 7 (KGF/FGF-7) and hepatocyte growth factor (HGF), transforming growth factor beta 1 (TGF-β1) were examined. The secretion rates of VEGF and KGF/FGF-7 were high in TS-SC, and the secretion rates of IGF-1 and HGF were high in TS-SCLF. TGF-β1 was inhibited in a concentration-dependent manner in all samples. Gene expression of VEGF, IGF-1, KGF, HGF and alkaline phosphatase, relevant to hair growth, were examined. The data revealed that TS-SC and TS-SCLF successfully promoted hair growth in hDPCs. The IGF-1 gene was expressed in a dose-dependent manner in TS-SCLF. These results indicate that TS-SC and TS-SCLF fermented extract effectively promoted hair growth and gene expression relevant to hair growth in hDPCs. Used in clinical trials the test substance 'CMK-LPF01' showed a statistically significant increase in the number of hairs at 8 weeks, 16 weeks, and 24 weeks compared to before product use, and a change in hair growth, a secondary efficacy evaluation variable. Through additional research in the future, it is expected that "CMK-LPF01" can be developed as a functional material that can help alleviate symptoms of hair loss.

Evaluation of the usefulness of Images according to Reconstruction Techniques in Pediatric Chest CT (소아 흉부 CT 검사에서 재구성 기법에 따른 영상의 유용성 평가)

  • Gu Kim;Jong Hyeok Kwak;Seung-Jae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.285-295
    • /
    • 2023
  • With the development of technology, efforts to reduce the exposure dose received by patients in CT scans are continuing with the development of new reconstruction techniques. Recently, deep learning reconstruction techniques have been developed to overcome the limitations of repetitive reconstruction techniques. This study aims to evaluate the usefulness of images according to reconstruction techniques in pediatric chest CT images. Patient study conducted a study on 85 pediatric patients who underwent chest CT scan at P-Hospital in Gyeongsangnam-do from January 1, 2021 to December 31, 2022. The phantom used in the Phantom Study is the Pediatrics Whole Body Phantom PBU-70. After the test, the images were reconstructed with FBP, ASIR-V (50%) and DLIR (TF-Medium, High), and the images were evaluated by obtaining SNR and CNR values by setting ROI of the same size. As a result, TF-H of deep learning reconstruction techniques had the lowest noise value compared to ASIR-V (50%) and TF-M in all experiments, and SNR and CNR had the highest values. In pediatric chest CT scans, TF images with deep learning reconstruction techniques were less noisy than ASiR-V images with adaptive statistical iterative reconstruction techniques, CNR and SNR were higher, and the quality of images was improved compared to conventional reconstruction techniques.

Quantitative analysis of hydrogen in thin film by scattering-recoil co-measurement technique (산란-되튐 동시 측정 방법에 의한 박막 중 수소 정량법)

  • Lee, Hwa-Ryun;Eum, Chul Hun;Choi, Han-Woo;Kim, Joonkon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.400-406
    • /
    • 2006
  • Hydrogen analysis by elastic recoil detection has been performed utilizing polyimide film as a reference sample of known hydrogen content assuming the soundness of ion beam current integration. However beam current integration at higher incidence angle is not reliable. Scattering yield per unit fluence by current integration which is normalized per unit path length decreases as the sample tilt angle is getting higher. Moreover because beam current integration at high tilt angle is incomplete, hydrogen evaluation is very risky by direct comparison of sequentially collected recoil spectra between reference and target sample. In this study, primary ion beam dose is determined by backscattering spectrum that is collected simultaneously with recoil spectrum instead of ion beam current integration in order to reduce uncertainty arising in the process of current integration and to enhance the reliability of quantitative analysis. Three test samples are selected $-7.6{\mu}m$ polyimide film, hydrogen implanted silicondioxide and Au deposited carbon wafer- and analyzed by two methods and compared.

Evaluation of Renal Pathophysiological Processes Induced by an Iodinated Contrast Agent in a Diabetic Rabbit Model Using Intravoxel Incoherent Motion and Blood Oxygenation Level-Dependent Magnetic Resonance Imaging

  • Yongfang Wang;Xin Zhang;Bin Wang;Yang Xie;Yi Wang;Xuan Jiang;Rongjia Wang;Ke Ren
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.830-843
    • /
    • 2019
  • Objective: To examine the potential of intravoxel incoherent motion (IVIM) and blood oxygen level-dependent (BOLD) magnetic resonance imaging for detecting renal changes after iodinated contrast-induced acute kidney injury (CI-AKI) development in a diabetic rabbit model. Materials and Methods: Sixty-two rabbits were randomized into 2 groups: diabetic rabbits with the contrast agent (DCA) and healthy rabbits with the contrast agent (NCA). In each group, 6 rabbits underwent IVIM and BOLD imaging at 1 hour, 1 day, 2 days, 3 days, and 4 days after an iohexol injection while 5 rabbits were selected to undergo blood and histological examinations at these specific time points. Iohexol was administrated at a dose of 2.5 g I/kg of body weight. Further, the apparent transverse relaxation rate (R2*), average pure molecular diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (f) were calculated. Results: The D and f values of the renal cortex (CO) and outer medulla (OM) were significantly decreased compared to baseline values in the 2 groups 1 day after the iohexol injection (p < 0.05). A marked reduction in the D* values for both the CO and OM was also observed after 1 hour in each group (p < 0.05). In the OM, a persistent elevation of the R2* was detected for 4 days in the DCA group (p < 0.05). Histopathological changes were prominent, and the pathological features of CI-AKI aggravated in the DCA group until day 4. The D, f, and R2* values significantly correlated with the histological damage scores, hypoxia-inducible transcription factor-1α expression scores, and serum creatinine levels. Conclusion: A combination of IVIM and BOLD imaging may serve as a noninvasive method for detecting and monitoring CI-AKI in the early stages in the diabetic kidney.

Study on the in vitro and in vivo anti-obesity effects of a combination of Syzygium aromaticum L. and Sorbus commixta Hedl. (정향과 마가목 복합물의 in vitro와 in vivo 항비만 효과 연구)

  • Ji Heon Yu;Hui Yeon An;Seong-Soo Roh;Mi-Rae Shin
    • Journal of Nutrition and Health
    • /
    • v.57 no.2
    • /
    • pp.196-210
    • /
    • 2024
  • Purpose: This study investigated the anti-obesity effects of a combination of Syzygium aromaticum L. and Sorbus commixta Hedl. (SS) in vitro and in vivo. Methods: The extracts of Syzygium aromaticum extract (SA) and Sorbus commixta extract (SC) were prepared individually using distilled water. They were mixed in a 1:2 ratio for use in the experiment. To assess the anti-obesity potential of SS in vitro, we examined cell proliferation, cellular triglyceride (TG), and total cholesterol (TC) levels, as well as lipogenesis and β-oxidation in 3T3-L1 cells. To confirm its anti-obesity potential in vivo, C57BL/6J mice were fed a 60% high-fat diet (HFD) to induce obesity. SA alone, SC alone, and their combination compound, SS (at a dosage of 200 mg/kg) were orally administered for 6 weeks. Thereafter, to conduct a comparative evaluation, serum analysis, western blotting of liver tissues, and histopathological analysis were performed. Results: Both SS200 and SS400 significantly inhibited the cellular TG and TC contents in the 3T3-L1 cells. Furthermore, treatment of the cells with SS (at a dose 200 and 400 ㎍/mL) also led to a noticeable regulation of key lipogenic and β-oxidation factors. Treatment of obese mice with SS resulted in a greater reduction in serum leptin and TG levels compared to treatment with the individual compounds (SA and SC). Furthermore, activation of AMP-activated protein kinase α by SS treatment resulted in the suppression of sterol regulatory element-binding proteins (SREBP)-1, leading to the inhibition of acetyl-CoA carboxylase (ACC) expression. Conclusion: Our results suggest that SS may have the potential to prevent obesity through a reduction in the TG and TC levels and regulation of lipogenesis and β-oxidation.

Evaluation of cyclooxygenase (COX) inhibition in rosemary extract (로즈마리 추출물의 cyclooxygenase (COX) 효소 및 유전자 발현에 미치는 영향)

  • Sehee Lee;Soo-yeon Park;Kyeong Jin Kim;Sonwoo Kim;Yanghoon P. Jung;Ji Yeon Kim
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.114-121
    • /
    • 2023
  • Selective cyclooxygenase (COX)-2 inhibition is a novel strategy to reduce the risk of gastrointestinal side effects caused by conventional nonsteroidal anti-inflammatory drugs. However, some selective COX-2 inhibitors have become apparent to increase the risk of severe cardiovascular disease. The aim of this study was to examine the anti-inflammatory effect of rosemary extract (RE) and confirm the safety of cardiovascular side effects. Inhibition of COX enzyme activity was assessed, and the levels of COX-2 and prostaglandin E2 (PGE2) and COX-1 and thromboxane B2 (TXB2) were evaluated in lipopolysaccharide (LPS)-induced RAW 264.7 cells. The 40% RE group showed increased COX-2 inhibition activity in a dose-dependent manner, whereas the 50% RE group only exhibited at 100 ㎍/mL. In a cell-based study, COX-2 mRNA expression was similar in both RE groups and PGE2 levels tended to decrease in the 40% RE group compared to the LPS group in the LPS pretreatment condition. In the LPS posttreatment condition, the COX-2 mRNA expression decreased in the 40% RE group, and PGE2 levels were increased in the 40 and 50% RE groups. In both conditions, there was no significant difference in COX-1 and TXB2 levels. In conclusion, 40 and 50% RE showed significant COX-2 inhibition, similar to the positive control group. It was confirmed that the inhibition of the COX-2 expression, but the effect did not affect the balance between prostacyclin and TXB2. These results indicate that rosemary showed COX-2 inhibition activity with a low risk of cardiovascular diseases.

Overview of Mitochondrial Encephalomyopathy with Lactic Acidosis and Stroke-like episodes (MELAS) syndrome (멜라스 증후군의 개요)

  • Ji-Hoon Na;Young-Mock Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Mitochondrial Encephalomyopathy with Lactic Acidosis and Stroke-like episode (MELAS) is a rare maternally inherited disorder primarily caused by mutations in mitochondrial DNA, notably the m.3243A>G mutation in the MT-TL1 gene. This mutation impairs mitochondrial function crucial for cellular energy production, particularly in high-energy-demanding organs such as the brain and muscles. MELAS manifests as recurrent stroke-like episodes, seizures, diabetes mellitus, cardiomyopathy, and other multisystemic symptoms that are often present in childhood. The diagnosis combines genetic testing, clinical evaluation, and neuroimaging, with elevated lactate levels and characteristic magnetic resonance imaging (MRI) findings as key indicators. Treatment focuses on symptomatic management and enhancement of mitochondrial function through L-arginine, coenzyme Q10, high-dose vitamins, and taurine supplementation. Studies have identified additional genetic variants linked to MELAS, including mutations in POLG and other mitochondrial genes, further complicating the genetic landscape. Emerging therapies, particularly gene therapy and mitochondria-targeting drugs, offer promising avenues for addressing the underlying genetic defects and improving mitochondrial functioning. Furthermore, ongoing studies continue to enhance our understanding and management of MELAS, with the aim of reducing its burden and improving patient outcomes and quality of life. This review summarizes the current knowledge on the genetics, clinical features, diagnosis, and treatment of MELAS, highlighting the latest advancements and future directions for therapeutic interventions.

  • PDF

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF