• 제목/요약/키워드: Dose Distribution

검색결과 1,176건 처리시간 0.026초

Effects of Millimetric Shifts in Breast Cancer Radiotherapy on the Radiation Dose Distribution

  • Sanli, Yusuf Tolga;Cukurcayir, Funda;Abacigil, Fatma
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.1197-1199
    • /
    • 2016
  • Background: This study aimed to facilitate decision-making in cases of breast cancer radiotherapy shifts by simulating millimetric shifts and analyzing their effects on dose distribution. Methods: The study included 30 patients with left side breast cancer who were treated with three dimensional conformal radiotherapy (3D-CRT) in the Radiation Oncology Department in Hatay Public Hospital, between January 2013 and April 2015. A treatment plan shifting at three axes with six different measures was simulated. Results: The biggest difference in values was (+3mm shift) 476cGy, with a 7.7 % change for heart and 25.6% for spinal cord. The shifts in values respectively for CTV min, mean, max were -4.8%, 2.5%, 4%. The differences for lymphatic min, mean, max were 21.3%, 20.3%, -12.2%. Conclusion: The most important thing is not the treatment plan quality, but its practicality. The treatment plan must be practical and its practice must be controlled rigidly.

요추 측면 검사 시 공간선량 분포와 피폭선량 (Spatial dose distribution and exposure dose during lumbar lateral test)

  • 김창규
    • 한국융합학회논문지
    • /
    • 제5권1호
    • /
    • pp.17-22
    • /
    • 2014
  • 요추 측면 X선 검사 시 피폭선량을 최소화 하고 진단에 최적의 영상을 얻기 위하여 유리선량계와 공간선량 측정계를 이용하여 장기별 피폭선량과 공간선량분포를 측정 평가 하였다. X선관과 가까울수록 장기의 피폭선량이 증가하였으며 조사야를 완전히 열었을 때 피폭선량이 증가되었다. 또한 피사체와 거리가 가까울수록 산란선이 증가하였으며 200 cm 이상 거리를 두면 95% 이상의 산란선이 감소되었다. 이 결과는 향후 요추 X선 검사 시 환자의 피폭선량을 예측하고 검사 방법을 결정하는데 자료로 제시되어 의료피폭선량을 감소 하는데 중요한 기초자료로 많은 활용이 있을 것으로 기대된다.

다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포 (Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses)

  • Kim, Sookil
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.83-88
    • /
    • 1999
  • 목적 : 금속박막과 고체 팬텀이 선량 분포와 선량 측정에 미치는 영향을 연구하기 위하여 TLD 실험을 행하였다. 본 연구의 목적은 주어진 고체 팬텀 환경 내에서 TLD 기판 위에 놓인 금속박막의 build-up 효과와 깊이선량 분포를 알아보고자 하였다. 대상 및 방법 : 측정은 TLD 기판과 같은 면적 (3.2 $\times$ 3.2 $\textrm{mm}^2$)의 금속박막을 LiF TLD-100 위에 얹어서 행하였다. 여러 종류 (주석, 구리, 금) 의 다양한 두께 (0.1, 0.15, 0.2, 0.3 mm)를 가진 금속박막 중에 한 개를 TLD 기판 위에는 얹어서 각 각의 흡수선량을 측정하였다. 금속박막을 얹은 TLD 기판을 사용하여 고체 팬텀에서의 표면홉수선량과 최대 build-up 영역에서 흡수선량을 측정하였다. 결과 : 금속박막을 이용한 TLD 기판의 경우 표면흡수선량이 증가하였고, 물에 대한 금속의 등가 두께에 따른 표면흡수선량 곡선에는 build-up 이 뚜렷이 관측되었다. 최대 build-up 영역에서 관측한 흡수선량 측정값은 금속박막을 없지 않은 TLD의 경우보다 약 8% 에서 13% 정도의 보다 작은 값을 나타내었다. 결론 : TLD 선량 측정 시 금속 박막 법은 깊이에 따른 흡수선량 뿐 만 아니라 피부 표면으로부터 약 4.2mm 깊이까지의 홉수선량의 build-up 에 관련 정보를 의료진에 제공할 수 있으며, 금속박막을 얹은 TLD에 관한 실험 결과는 피부 특정 영역에서의 bolus 의 결정에 도움이 될 것으로 사료됨.

  • PDF

두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰 (The usefulness of Forward IMRT for Head and Neck Cancer)

  • 백금문;김대섭;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.41-52
    • /
    • 2003
  • I. 목적 방사선 치료계획에 있어서 정상조직의 선량과 치료부위 선량의 분포는 매우 중요하다. 또한 치료부위의 균일한 선량분포를 얻기 위하여 여러 가지 방법을 이용하고 있다. 특히 두경부(Head & Neck) 종양의 방사선 치료 시 체표 윤곽의 변화가 심하여 이에 따른 선량 불균일 보정이 필요하다. 기존의 치료방법으로는 parotid gland 와 spinal cord 의 tolerance dose 이하를 유지하면서 planning target volume(PTV)에 충분한 치료 선량을 전달하기에는 여러 가지 어려움이 있다. 이에 본원에서는 Forward IMRT를 이용한 방사선 치료의 유용성 및 실용적인 정도관리 방법에 관한 연구를 하였다. II. 대상 및 방법 본 연구는 두경부(Head & Neck) 종양 비인두암(nasophrygeal cancer)의 방사선 치료가 요구되는 환자를 대상으로 하여 2차원적인 치료계획과 dynamic Mulit-Leaf Collimator(dMLC)를 이용하여 partial block technique(PBT)방법을 적용한 Forward IMRT를 위한 치료계획을 dose volume histogram(DVH)로 비교 분석하였다. 또한 정도관리(quality assurance, QA)를 위하여 필름과 pinpoint chamber를 이용하여 정확한 선량 평가를 실시하였다. III. 결과 2차원적인 치료계획과 Forward IMRT를 적용한 치료계획의 DVH를 비교 분석한 결과 Forward IMRT를 적용한 치료계획이 Rt, Lt parotid gland와 spinal cord에 들어가는 선량을 좀더 줄일 수 있었다. 이러한 Forward IMRT의 시도로 조사면의 방사선 세기가 정상조직의 보호를 개선시키고 치료의 최적화를 이룰 수 있었다. Inverse IMRT에 비해 기존의 3차원적 치료계획 장치를 이용할 수 있고 비교적 단순한 방사선 세기 패턴이므로 정도관리가 용이하였다. IV. 결론 Forward IMRT는 2차원적인 치료법에 비하여 PTV에는 균일한 선량분포를 이루면서 정상조직에는 tolerance dose 이하로 선량을 전달 할 수 있는 치료기법이었다.

  • PDF

강내형 X선 튜브 온도 및 선량 분포 특성 (The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube)

  • 조성호;이레나
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.262-266
    • /
    • 2013
  • 신개념 치과용 X선 촬영장치인 강내형 X선 튜브에 대한 연구가 소개되었다. 이는 초소형의 X-선 튜브를 구강내 삽입하여 외부에서 검출기로 영상을 획득하는 새로운 시스템이다. 본 연구에서는 구내 치근단 촬영을 위해 사용하는 강내형 X선 튜브의 온도분포 및 선량 분포 특성을 조사하였다. X선 튜브의 온도특성을 파악하기 위하여 튜브 표면에 써머커플을 부착하여 튜브 표면에서부터 거리에 대한 온도를 측정하였으며, EBT 필름을 이용하여 튜브표면에서부터 거리에 따른 선량 분포를 측정하였다. 그 결과 냉각장치가 없는 튜브에서 2mm 이상 거리에서 온도는 $27^{\circ}C$로 일정하였으며, 튜브에서 3cm, 5cm일 때 선량분포가 3.14, 1.84mGy로 나타났다. 그 결과 제안한 시스템은 기존 시스템에 비해 낮은 선량에서 안전하게 촬영이 가능한 것으로 향후 구내 치근단 촬영장치에 새로운 변화를 가져올 수 있을 것으로 사료된다.

중성자(中性子) 및 감마선(線)에 대한 선량율(線量率) 환산인자(換算因子) 계산(計算) (Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors)

  • 권석근;이수용;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제6권1호
    • /
    • pp.8-24
    • /
    • 1981
  • This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute(ANSI) N666. These data are used to calculated the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from $2.5{\times}10^{-8}$ to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoetiergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be a useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions.

  • PDF

Prediction of radiation dose to adult human from radiopharmaceutical manufactured by third generation bisphosphonate labeled with Rhenium

  • Zahra Pourhabib;Hassan Ranjbar
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.669-673
    • /
    • 2023
  • Introduction: The crucial step in preclinical process of radiopharmaceutical production is internal dosimetry evaluation by different ways to realize radiobiological dose-response relationships and to extract the results for clinical use. Till now several bone-seeking radiopharmaceuticals have been developed for bone metastasis. Interesting features of bisphosphonates attracted attentions to them in the field of radiopharmaceutical therapy and studies on new generation of them have been doing too. Materials and methods: In this study, we used ZNA as representative of the third generation. The radiopharmaceutical 188Re-ZNA was produced and its radiochemical purity was investigated. Then, the biological distribution of the produced radiopharmaceutical at 1, 2, 4 and 24 h after injection on different organs of mice were investigated. Finally, the absorbed dose of organs in the human body was assessed using the RADAR method. Results: The results show 96% radiochemical purity of the 188Re-ZNA radiopharmaceutical. The amount of %ID/g in bone is 1.131% after 1 h and in 24 h it has a significant amount compared to other organs, that is 0.516%. Also dosimetric results show that the highest absorption dose is related to bone and the amount of this dose is 0.050 mGy/MBq. Conclusion: Considering the possibility of producing the 188Re-ZNA radiopharmaceutical, as well as the proper distribution of this radiopharmaceutical in target and non-target organs and increasing the absorbed dose in bone, it can be concluded that this radiopharmaceutical can be useful in the "radiopharmaceutical therapy" in metastases.

EBT-3 필름을 사용한 감마나이프 퍼펙션TM의 치료 계획 시스템 및 선량 분포 비교 분석 (Comparative Analysis of Treatment Planning System and Dose Distribution of Gamma knife PerfexionTM using EBT-3 Film)

  • 진성진;김성진;서원섭;허병익
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.509-515
    • /
    • 2017
  • 본 연구는 EBT3 필름을 이용하여 감마나이프 퍼펙션 모델의 3차원적인 선량분포 측정하고 기준값과 비교 분석하여 표준화된 측정방법의 기초로 활용하고자 한다. 2개 종합병원에 설치된 감마나이프 퍼펙션 모델의 선량 분포를 EBT3 필름을 이용하여 정확도와 정밀도를 평가하였다. 정확도 평가를 위해 4 mm 콜리메터를 사용하여 기계적인 중심축과 선량중심축의 일치도를 측정하였다. A병원 0.098 mm, 0.195 mm 이며 B 병원 0.229 mm, 0.223 mm 로 허용 오차 0.3 mm 이하로 측정되었다. 정밀도 평가는 4, 8, 16 mm 콜리메터(collimater) 각각의 x, y, z 3차원면 에서의 반치폭(FWHM : Full Width at Half Maximum)을 이미지-제이 프로그램을 이용하여 평가하였다. A 병원은 -0.283~0.583 mm, B 병원은 -0.857~0.810 mm로 50%선 ${\pm}1mm$ 이하의 기준에 적합하였다. 이미지-제이 프로그램을 이용한 선량 분포 분석의 경우 측정자 간의 오차가 발생 가능함으로 측정점에 대한 명확한 기준을 확립할 필요가 있으며, 감마나이프 방사선 수술이 시행되어지는 고선량 영역에서 사용 가능한 선량영역이 높은 필름을 이용한 치료계획과 실제 치료 조사면의 비교가 필요하다고 생각된다.

Contrasting Correlation in the Inhibition Response of ADP-induced Platelet Aggregation and the Anti-coagulant Activities of Algal fucoidans Derived from Eisenia bicyclis and Undaria pinnatifida sporophylls (Mekabu)

  • Jeong, Eui-Sook;Yoon, Yeon-Hee;Kim, Jong-Ki
    • Fisheries and Aquatic Sciences
    • /
    • 제12권3호
    • /
    • pp.194-202
    • /
    • 2009
  • Sulfated fucans are known to have both anti-thrombotic and anti-coagulant activities. In this study, the variation in platelet aggregation and anti-coagulant activities was investigated in vitro with regard to administered dose, molecular weight distribution, sulfate content, and sugar composition in two algal fucoidans from Eisenia bicyclis and Undaria pinnatifida sporophylls (Mekabu). The anti-coagulant activity largely correlated with sulfate content and with molecular weight distribution in a dose-dependent manner. However, both fucoidans demonstrated inhibitory responses to ADP-induced platelet aggregation in dose- and structure-dependent manners that contrasted with the anti-coagulant activity. Neither molecular weight distribution nor sulfate content greatly affected platelet-aggregation inhibition (PA-inhibition) by the fucoidan fractions, whereas anti-coagulant activity was sensitive to these structural factors. Interestingly, an E. bicyclis fucoidan fraction exhibited almost complete PA-inhibition at a treatment dose of 500 mg/mL while retaining weak anti-coagulant activity. In conclusion, these observations suggest that fucoidan may be a useful anti-thrombotic or anti-platelet agent in various arterial thrombotic disorders, including post-vascular intervention with controlled bleeding complications, due to its anti-coagulant modulating activity.