• 제목/요약/키워드: Dose Attenuation

검색결과 169건 처리시간 0.024초

팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구 (IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT)

  • 김유현;여인환;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF

Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성 (Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator)

  • 김옥배;최태진;김영훈
    • Radiation Oncology Journal
    • /
    • 제8권1호
    • /
    • pp.115-124
    • /
    • 1990
  • 고 에너지 23MV광자선의 특성 중 임상적용에 중요한 심부선량 백분율, 조직-최대선량비 (TMR), 산란-최대선량비 (SMR), 표면선량 및 출력선량 보정계수등의 변수가 이온전리 (IC-10)함 및 평행 평판전리 (PS-033)함에 의해 측정 조사되었다. 명목상의 23 MV X-선에 대한 가속에너지는 $18.5\pm0.5$ MV로 측정되었다. Mevatron KD 8067의 23 MV X-선의 중심선속의 반가층이 기하학적인 좁은 선속으로 측정되었으며 반가층의 두께는 $24.5\;g/cm^2$이었다. 조직-최대선량비는 심부선량백분율표에서 구해졌으며, 실측치와 비교한 결과 각 조사면의 크기와 깊이에서 약간의 차이를 보였으나 평균 $0.7\pm0.5$의 오차를 나타내고 있어 계산에 의한 TMR 값과 잘 일치함을 보였다. 조사면 $0\times0\;cm^2$의 TMR 값은 zero 조사면의 유효감약계수에 의한 값과, 각 조사면의 조직-최대 선량비로 부터 비선형최소자승법에 의해 구해진 유효선흡수계수 및 반가층 측정에 의한 유효선흡수 계수에 의한 값들로 비교되었으며, $\mu=0.0283{\pm}0,0002cm^{-1}$을 보였고, 세 방법 모두 오차범위내에서 잘 일치됨을 보였다. 한편, 불규칙 조사면의 선량계산에 이용될 SMR은 조사면의 반경 50cm까지 계산되어 대형 조사 면에서도 선량율 산출이 이루어지도록 하였다. Mevatron KD 8067의 23 MV X-선의 조직 표면선량은 SSD 100 cm, 1$10\times10\;cm^2$의 조사면에서 최대조직선량율의 $9.6\%,\;25\times25\;cm^2$에서는 $25.4\%$를 보였다.

  • PDF

고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향 (Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source)

  • 김진기;김정수;김형진;권형철;강정구
    • 한국의학물리학회지:의학물리
    • /
    • 제8권1호
    • /
    • pp.37-45
    • /
    • 1997
  • 차폐된 질 원주기구를 이용한 강내치료시 Co-60 선원에 대한 정확한 흡수선량을 결정 하고자 선원을 교정하고, 질 원주기구에 의한 선량분포변화를 조사하였다. 선량분포의 변화량은 직경 2.5 cm 차폐된 질 원주기구를 폴리스틸렌 팬톰에 설치하여 전리함으로 측정하였으며, 부채꼴 모양인 0.55cm 두께의 9$0^{\circ}C$ 연으로 차폐된 면과 차폐되지 않은 면의 선량분포에 대한 영향을 상대선량 감소율로 측정하였다. 측정된 선량분포의 변화량을 제작사의 선량분포도 및 다점 분할방식으로 구한 선량율표와 비교하였다. 질 원주기구를 이용한 선량 감소율은 차폐되지 않은 변의 경우 원주기구 표면 1cm 거리에서 4.4%를 보였고, 차폐된 면에서는 원주기구 표면에서 20.4% 를 나타냈다. 9$0^{\circ}C$연 차폐된 질 원주기구의 선량감쇄효율은 Co-60 선원에서 평균 0.2가 되었다. Co-60 이동형 선원의 선량분포는 다 점분할방식의 선량율표와 4.1% 이내로 일치하였다.

  • PDF

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제27권2호
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

3D 프린팅 팬텀의 섬광카메라 적용 평가 (Evaluation of Scintillation Camera Applications of 3D Printing Phantom)

  • 박훈희;이주영;김지현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.

진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향 (The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT)

  • 정영진;강도영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권3호
    • /
    • pp.169-176
    • /
    • 2006
  • 목적 : 현재 PET/CT에서 CT의 역할은 단순히 감쇠 보정만을 위한 도구에서 진단을 위한 도구로 그 역할이 발전해 가고 있다. 따라서 양질의 CT 영상을 얻기 위한 정맥 조영제의 사용과 고선량의 CT 촬영이 요구되고 있으며 최근 조영제가 감쇠 보정한 PET 영상에 크게 영향을 미치지 않는다는 보고가 나오고 있다. 이에 본 연구에서는 고선량 CT에서 정맥 조영제의 사용이 감쇠 보정에 미치는 영향을 알아보았다. 대상 및 방법 : 총 13명의 환자에게 PET/CT 검사를 시행하였다. $^{18}F$-FDG를 주사하고 1시간 후에 촬영하였고, 첫 번째로 조영제의 사용 없이 CT(NECT-120 kVp, 130 mAs)를 촬영하고 이어서 바로 조영제를 사용하여 CT(CECT)를 촬영한 후 PET을 시행하였다. 각 환자마다 NECT와 CECT에 의해 각각 보정된 PET 영상에서 10곳의 신체 부위(병변이 없는 폐첨부, 폐기저부, 상행대동맥, 간의 상부 및 하부, 비장, 척추, 대퇴골두, 장요근과 10번 척추와 척추 인접 근육) 에서 HU와 maxSUV 값을 구하였고, 종양과 임파선 병변의 값도 함께 측정하였다. 결과: 조영제를 사용하였을 때 국소적으로 섭취가 증가된 곳은 관찰되지 않았다. 총 130개의 정상 조직의 maxSUV값을 측정하여 비교하였을 때, 조영제를 사용한 군과 사용하지 않은 군의 평균 maxSUV 값은 각각 $1.1{\pm}0.5,\;1.0{\pm}0.5$이고 두 군 사이에 p<0.001로 통계적으로 유의한 차이를 보였다. 정상 조직에 대해 Bland-Altman 분석을 시행하였을 때 일치의 한계 범위는 $0.1{\pm}0.3$ 이었다. 10개의 대상 영역 중 폐첨부, 폐하부, 상행대동맥, 간의 상부와 하부, 비장에서 maxSUV 값이 두군에서 유의한 차이(p<0.05)가 있었다. 총 39개 병변의 maxSUV 값을 측정하여 비교하였을 때, 조영제를 사용한 군과 사용하지 않은 군의 평균 maxSUV값은 각각 $4.7{\pm}2.0,\;4.4{\pm}2.0$이고 두 군 사이에 p<0.001로 통계적으로 유의한 차이를 보였다. 병변에 대해 Bland-Altman 분석을 시행하였을 때 일치의 한계 범위는 $0.4{\pm}0.8$ 이었다. 결론: 조영제로 인해 maxSUV의 값은 증가되었으나 정상 조직과 병변에서 일치의 한계 범위가 매우 좁았다. 따라서 진단용 고선량 CT를 이용한 PET/CT 촬영 시에 조영제의 사용이 임상 상황에서 판독에 큰 영향을 미치지 않는 것으로 생각된다.

영상 정보 손실을 최소화하는 방사선 차폐체 연구 (Radiation Shielding to Minimize Image Information Loss)

  • 장수한;박상현;주명식
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.449-457
    • /
    • 2023
  • 방사선 감수성이 높은 부위의 방사선 검사 시 피폭선량 감소를 위해 사용하는 차폐체가 조사야에 포함될 경우 방사선 영상에서 밝게 표현되며 영상 정보의 손실이 발생한다. 영상 정보의 손실은 진단과 치료에 제한점을 주며 재촬영이 필요할 경우, 불필요한 방사선에 노출될 수 있다. 본 논문에서는 수용성 요오드 조영제와 물을 혼합한 다양한 농도의 차폐체를 제작하여 영상 손실을 최소화하면서 기존 차폐체와 동등한 차폐 효과를 발생하는 방사성 방호 차폐체를 연구하고자 하였다. 차폐체는 물 100 ml, 수용성 요오드 조영제 100 ml, 수용성 요오드 조영제와 물을 20 : 80, 40 : 60, 60 : 40, 80 : 20 비율로 각각 100 ml를 제작했다. 차폐 효율을 측정하기 위해서 차폐체를 가로 9.5 cm, 세로 9.5cm의 플라스틱 용기에 약 1.5 cm 높이로 담고 흡수선량 감쇠율을 평가하였다. 조사 조건은 골반 촬영 조건을 기준으로 5회 반복 측정하였고 측정한 조사선량 값을 흡수선량 값으로 변환한 뒤 평균값을 산출 비교하였다. 영상 정보 손실 정도는 팬텀의 골반강 부위를 차폐하고 획득한 영상을 근골격 전문의 2명과 방사선사 8명이 주요 해부학적 구조물의 관찰 정도를 평가 후 선택하였다. 또한 차폐한 부위의 영상에서 표현되는 골격과 가스의 신호 강도 차이를 분석한 결과 방사선 감쇠 효율성은 수용성 요오드 조영제의 비율이 높을수록 높은 차폐 효율을 나타냈다. 영상 정보의 손실 평가에서 평가자들은 수용성 요오드 조영제 20 ml 혼합물에서 해부학적 구조물의 관찰이 용이하다 평가하였으며 60 ml 이상의 혼합물에서는 구조물의 관찰이 불가능하였다. 골격과 가스의 신호강도 차이는 p < 0.001로 평균값의 차이가 유의미한 차이가 있었으며, 조영제의 농도가 높을수록 신호 강도의 차이는 적었다. 수용성 요오드 조영제 차폐체는 방사선 감쇠 효율이 기존의 차폐체 보다 떨어지지만, 차폐체가 관찰하는 목적부위 이거나 가까이 위치하여 차폐체를 적용하지 못하는 경우에 사용한다면, 영상 손실을 최소화하며 보다 더 적극적인 방사선 방호의 역할을 수행할 수 있다.

IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가 (Development of the IRIS Collimator for the Portable Radiation Detector and Its Performance Evaluation Using the MCNP Code)

  • 지영용;정근호;이완로;최상도;김창종;강문자;박상태
    • 방사성폐기물학회지
    • /
    • 제13권1호
    • /
    • pp.55-61
    • /
    • 2015
  • 방사선검출기를 이용한 고방사성물질의 측정이나 방사선사고 등의 신속한 대응을 위하여 주위의 선량률 준위에 따라 크기별로 여러 종류의 콜리메이터들을 구비해야 하며, 이는 무거운 콜리메이터의 특성상 효율적인 현장 측정에 심각한 장애가 될 수 있다. 본 연구에서는 콜리메이터의 모양을 카메라의 렌즈 조리개 형식으로 제작하여 사용자가 직접 카메라 렌즈를 돌려 초점을 맞추듯이 콜리메이터의 내경을 조절하고 방사선의 감쇄율을 쉽게 알아볼 수 있도록 IRIS형 콜리메이터를 제작하였다. 먼저, 콜리메이터를 위상을 달리한 2 중의 텅스텐 셔터 구조로 제작하여 기계적 공차에 의한 방사선의 침투를 차단하고자 하였다. 그리고 셔터의 재질별로 콜리메이터 내경에 따른 방사선 감쇄율을 MCNP 코드를 이용하여 계산함으로써 이론적인 성능평가를 수행하였다. 계산된 내경의 크기별 감쇄율을 콜리메이터 외부 눈금링에 표시함으로써, 카메라 렌즈에 표시된 배율과 같은 방법으로 사용자가 해당 표시지점으로 콜리메이터 내경을 조절하였을 때, 방사선의 세기가 얼마만 큼 감소되는지 쉽게 알아볼 수 있도록 구현하였다. 끝으로 개발된 IRIS형 콜리메이터를 장착한 소형 방사선검출기를 현장 측정에 활용할 경우, 콜리메이터의 교체 없이 주위 방사선의 세기에 따라 콜리메이터 내경을 적절한 크기로 신속히 교체가 가능하며, 방사선 세기의 감쇄 정도를 쉽게 알아보게 함으로써 신속하고 정확한 대처가 가능할 것으로 판단된다.