• Title/Summary/Keyword: Doppler scanning

Search Result 42, Processing Time 0.025 seconds

Measurement of Vibration Mode Shape By Using Hilbert Transform (Hilbert Transform을 이용한 진동모드 측정)

  • Kang, Min-Sig
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.392-397
    • /
    • 2001
  • This paper concerns on modal analysis of mechanical structures by using a continuous scanning laser Doppler vibrometer. In modal analysis the Hilbert transform based approach is superior to the Fourier transform based approach because of its fine accuracy and its flexible experimental settings. In this paper the Hilbert transform based approach is extended to measure area mode shape data of a structure by simply modifying the scanning pattern ranging the entire surface of the structure. The effectiveness of this proposed method is illustrated along with results of numerical simulation for a rectangular plate.

  • PDF

Scanning Rayleigh Doppler Lidar for Wind Profiling Based on Non-polarized Beam Splitter Cube Optically Contacted FPI

  • Zheng, Jun;Sun, Dongsong;Chen, Tingdi;Zhao, Ruocan;Han, Yuli;Li, Zimu;Zhou, Anran;Zhang, Nannan
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.195-202
    • /
    • 2018
  • A Scanning Rayleigh Doppler lidar for wind profiling based on a non-polarized beam splitter cube optically contacted FPI is developed for wind measurement from high troposphere to low stratosphere in 5-35 km. Non-polarized beam splitter cube optically contacted to the FPI are used for a stable optical receiver. Zero Doppler shift correction is used to correct for laser or FPI frequency jitter and drift and the timing sequence is designed. Stability of the receiver for Doppler shift discrimination is validated by measuring the transmissions of FPI in different days and analyzed the response functions. The maximal relative wind deviation due to the stability of the optical receiver is about 4.1% and the standard deviation of wind velocity is 1.6% due to the stability. Wind measurement comparison experiments were carried out in Jiuquan ($39.741^{\circ}N$, $98.495^{\circ}E$), Gansu province of China in 2015, showing good agreement with radiosonde result data. Continuous wind field observation was performed from October 16th to November 12th and semi-continuous wind field of 19 nights are presented.

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

Transcranial Doppler: examination techniques and interpretation

  • Do, Youngrok;Kim, Yong-Jae;Lee, Jun Hong
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • Transcranial Doppler (TCD) was introduced in 1982 to assess intracranial arteries noninvasively, since when it has been widely used to assess and monitor cerebrovascular hemodynamics. The clinical applications of TCD are broadening to include other fields that require monitoring of the cerebral blood flow. TCD has fewer temporal and spatial restrictions than other methods, can be performed on less-compliant patients, and causes no harm to the body. However, its reliance on high levels of examiner skill and experience, as well as a lack of standardized scanning protocols are obstacles that still need to be overcome. In this report we review TCD examination techniques and interpret their findings for several conditions.

OMA testing by SLDV for FEM Updating

  • Milla, Brian-Mac;Mehdi Batel;Eddy Dascott;Ben Verbeeck
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.840-840
    • /
    • 2003
  • Operational Modal Analysis (OMA) is a technique for identification of modal parameters by measurement of only the system's response. On many lightweight structures, such as load-speaker cones and disk drive read/write heads, is impossible or impractical to measure the input forces. Another characteristic of lightweight structure is their sensitivity to mass loading from sensors. The Scanning Laser Doppler Vibrometry(SLDV) allows response measurements to be taken without mass loading. One disadvantage of OMA testing compared to tradition input output modal testing is the OMA mode shapes are un-scaled. This means that the mode shape obtained from an OMA test can not used for analytical structural modification studies. However, the un-scaled mode shapes from an OMA test can be used to update a Finite Element Model (FEM). The updated FEM can then be used to analytically predict the effect of structural modifications. This paper will present the results of an OMA test performed on a simple plate and motor in operating conditions. The un-scaled mode shapes from this test will be used to update a FEM model of the system. The updated FEM model will be then be used to predict the effect of attaching a mass to the plate. The shapes predicted by the FEM for the modified system will be compared to a second OMA test on the modified system

  • PDF

Characterization of Frequency Separation in Polymer Membranes Mimicking a Human Auditory System (생체 청각기구를 모사한 폴리머 박막의 주파수 분리 특성 평가)

  • Song, Won-Joon;Bae, Sung-Jae;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.516-521
    • /
    • 2011
  • The basilar membrane, an important functional part of the cochlea, is responsible for spectral separation of vibration signals transmitted from the stapes. In current study, scaled-up polymer membranes designed by mimicking the human basilar membrane were used for investigation of the frequency-separation characteristic. Displacement field formed on each polymer membrane was acquired by Laser Doppler scanning vibrometer and post-processed frequency-wise. The locations of the maximum displacement along the centerline were identified and collected for individual frequency range to produce the frequency-position map of individual polymer membrane. The influences of the membrane thickness and material properties on the variation of the frequency separability were discussed.

Three-dimensional vibration measurement algorithm using one laser scanning vibrometer (한대의 LSV 를 이용한 3 차원 진동측정방법)

  • Kim, Dong-Kyu;Song, Ha-Jun;Park, Kyi-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.935-939
    • /
    • 2012
  • 3D vibration measurement is achieved using one laser scanning vibrometer(LSV) and Laser scanner(LS) by moving the LSV to three arbitrarily locations from the principle that vibration analysis based on the frequency domain is independent of the vibration signal based on time domain. The proposed system has the same effect as using three sets of LSVs. It has an advantage of reducing equipment costs. Analytical approach of obtaining in-plane and out-of-plane vibration of surface is introduced using geometrical relations between three LSV coordinates and vibration measured at three different locations.

  • PDF

Moving Clutter Signal Measurement and Its Spectral Analysis for Airborne Pulse Doppler Radar (비행 탑재 레이다의 이동 클러터 신호 수집 및 도플러 스팩트럼 특성 분석)

  • Jeun, In-Pyung;Choi, Min-Su;Hwang, Kwang-Yun;Kwag, Young-Kil
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.439-442
    • /
    • 2005
  • An airborne radar performance can be sensitive to the variation of the Doppler center frequency and the spectral spread of the ground clutter return due to the radar platform moving and aspect angle of the scanning beam to the target. In this paper, for the performance test of the airborne pulsed Doppler radar system developed, the high-speed radar data acquisition system is implemented for acquiring the raw radar signal in real-time. Based on the various test scenarios from airborne-platform to the moving platform, the various radar target and clutter signals are collected and their spectrum is analyzed for the verification of the radar performance in the real-time flight test environments.

  • PDF

Localization of Human Motion Using a 8×8 Phased Array Antenna (8×8 위상배열안테나를 이용한 위치추적 시스템)

  • Goh, Hoseok;Han, Heeje;Park, Soonwoo;Kim, Chan-woo;Kim, Hongjoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1197-1201
    • /
    • 2018
  • In this paper, a Doppler radar for a localization of a human motion is demonstrated. In the system, we used a $8{\times}8$ phased array antenna using metamaterial phase shifters for easy and precise control of antenna beam pattern. Scanning area is a circular sector with an inscribed angle of $60^{\circ}$ and a diameter of 45m. This area is divided with 15 designated area and each area is scanned for 0.2 second. When there is a motion in a designated area, we are able to detect a frequency shift due to a Doppler effect. In this way it is possible to detect the location of motion. The experiment shows that 78% of position accuracy. The remaining 22% occurred the surroundings of the designated area.