• 제목/요약/키워드: Doppler center

검색결과 270건 처리시간 0.028초

Descending Aorta Blood Flow Characteristics before the Development of Necrotizing Enterocolitis in Preterm Neonates

  • Kim, Kyung Min;Kim, Hyo Sup;Yoon, Ji Hong;Lee, Eun-Jung;Yum, Sook Kyung;Moon, Cheong-Jun;Youn, Young-Ah;Kwun, Yoo Jin;Lee, Jae Young;Sung, In Kyung
    • Neonatal Medicine
    • /
    • 제25권2호
    • /
    • pp.78-84
    • /
    • 2018
  • Purpose: To investigate the hemodynamic risk factors for necrotizing enterocolitis (NEC), we analyzed the characteristics of descending aorta (DA) blood flow in preterm neonates, who later developed NEC. Methods: This was an observational case-control study on 53 preterm neonates at a tertiary referral center. Clinical and echocardiographic data were collected from 23 preterm neonates with NEC (NEC group), and compared with those of 30 preterm neonates without NEC (control group). Echocardiography was done at a median (interquartile range) of 5 (3-9) days after birth and 2 (1-2.5) days before the diagnosis of NEC. Results: Basic clinical characteristics including gestational age, birth weight, Apgar score, breast feeding status, use of umbilical catheters, and mode of invasive ventilator care were similar between the groups. Compared with the control group, the lowest diastolic velocity of DA was significantly decreased, whereas the diastolic reverse flow and the ratio of diastolic reverse to systolic forward flows were significantly increased in the NEC group. In addition, the resistive index (RI) of DA was significantly increased in the NEC group and showed a positive association with the development of NEC. Multivariate logistic regression analysis showed that increasing RI of DA was an independent risk factor for the development of NEC (P=0.008). Conclusion: Significant changes in DA flow characteristics including decreased diastolic velocity and increased diastolic reverse flow along with increased peripheral vascular resistance were observed before the development of NEC in preterm neonates. These findings may help clinicians stratify in advance neonates at a risk of developing NEC and may help improve outcomes in these neonates.

뇌경색 환자의 경동맥 초음파 검사와 24시간 홀터 검사와의 연관성 연구 (The Relationship between Carotid Intima-Media Thickness and 24-hour Ambulatory ECG in Ischemic Stroke Patients)

  • 강지석;박성환;송문구;안영민;안세영;이병철
    • 대한한방내과학회지
    • /
    • 제30권2호
    • /
    • pp.422-430
    • /
    • 2009
  • Background : Stroke is the second leading cause of death in Korea, following cancer. Stroke consists of ischemic and hemorrhagic stroke, and ischemic stroke can be largely classified as atherothrombotic stroke or embolic stroke. Carotid intima-media thickness (IMT) is an indicator of atherosclerosis used commonly as a screening test for abnormalities of the coronary artery. 24-hour ambulatory ECG is widely used to screen for underlying diseases that causes syncope, palpitation, arrhythmia, etc. Objectives : Since both carotid IMT and 24-hour ambulatory ECG are used to screen for cardiac problems, we endeavored to explore the correlation between carotid IMT and 24-hour ambulatory ECG of stroke patients. Methods : The records of ischemic stroke patients who were admitted to Kyunghee Medical Center Oriental Hospital ward from March 2006 to May 2009 were reviewed. 28 patients who had both carotid Doppler US and 24-hour ambulatory ECG test undertaken during their admission were analyzed. The relationship of abnormal ambulatory results and common carotid artery(CCA) IMT were statistically analyzed using Fisher's exact test and t-test. Results : The mean age of the abnormal ambulatory group was older than the normal group (74${\pm}$ 8.0 vs. 61${\pm}$12.1, p=0.0098). Although insignificant, the abnormal ambulatory group showed much thicker CCA-IMT than normal ambulatory group (2.l7${\pm}$ 1.16 vs. 1.51${\pm}$0.97. p=0.l389). Conclusion: No significant correlation was observed between abnormal ambulatory results and CCA-IMT. However, the difference in CCA-IMT between the two groups was too big to be ignored and further investigation with larger and better controlled trials are warranted.

  • PDF

산지지역 수재해 대응을 위한 레이더 기반 돌발성 호우 위험성 사전 탐지 기술 적용성 평가 (Applicability evaluation of radar-based sudden downpour risk prediction technique for flash flood disaster in a mountainous area)

  • 윤성심;손경환
    • 한국수자원학회논문집
    • /
    • 제53권4호
    • /
    • pp.313-322
    • /
    • 2020
  • 국토의 70% 이상이 산지인 우리나라의 경우 산지지역의 돌발호우로 인한 수재해의 위험이 상시 존재한다. 본 연구에서는 환경부 비슬산 강우레이더 관측 영역의 산지지역에 발생한 돌발성 호우 사례를 대상으로 레이더 기반 돌발성 호우 사전 예측 방법을 적용하여, 그 활용성을 살펴보았다. 비슬산 강우레이더의 3차원 레이더 반사도, 강우강도, 도플러 풍속을 이용하여, 산지지역에서 발생한 8개의 국지적 호우 사례를 선정한 후 적란운 대류세포의 조기탐지, 탐지된 대류세포의 자동 추적, 해당 대류세포가 발달하여 돌발성 호우를 유발할 수 있는 가능성을 판단하는 위험도 정보를 산출하였다. 사례적용 결과, 대기 중에 돌발호우로 발달할 수 있는 대류세포의 최초 탐지시점 및 위치, 소용돌이도 발생여부에 따라 판정된 위험도 수준 및 발생시점, 위치를 확인할 수 있었다. 특히, 지상강우관측망으로는 좁은 영역에 국지적으로 발달하는 호우를 탐지하는데 한계가 있음을 확인하였다. 또한, 위험도 정보를 획득한 시점에서 최대 강우강도가 발생할 때까지 최소 10분에서 최대 65분 정도의 시간을 확보함으로써 레이더 기반의 돌발성 호우 사전 예측기법은 산지지역에서 호우로 인한 산지홍수, 고립사고 방지를 위한 사전정보로 활용성이 있을 것으로 판단되었다.

인공용승구조물 설치에 의한 유동변화 ( I ) (The Variation of Current by the Building of Artificial Upwelling Structure ( I ))

  • 김동선;황석범
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.301-306
    • /
    • 2006
  • 인공용승구조물 설치해역의 구조물에 의한 유동분포를 파악하기 위하여 ADCP(Acoustic Doppler Current Profiler)를 이용한 정선관측을 2006년 5월 4일(소조기) 및 5월 30일(대조기)에 실시하였다. 동서-남북(un-component) 유동성분의 분석결과, 조시에 따른 흐름이 전반적으로 남동류가 우세하게 나타났으며 구조물 주변역의 표층에서 수심 $30\sim40m$까지의 유동과 이심에서의 유동이 서로 다르게 나타났다. 연직유동성분(w-component)은 소조기시 구조물 주변해역과 서쪽역에서는 상승류의 흐름이 나타났고 남쪽역, 북쪽역 및 동쪽역에서는 하강류의 흐름이 나타났다. 대조기 W-W line의 낙조시에는 동쪽과 서쪽해역에서 상승류의 흐름이 나타났으며 구조물 중심 동쪽 부근에서 상승류의 흐름이 나타났고 구조물에서 멀어질수록 하강류의 흐름이 나타났다. 대조기시의 분포는 창조시 S-N line에서 상승류의 분포가 전반적으로 나타났다. 또한 구조물 구축 주번해역에서의 단위면적당 상승류의 유량은 대 소조기 창 낙조시에 하강류에 대한 유량보다 크게 나타났다. 소조기에는 창조시보다 낙조시에 더 강하였으며, 대조기에는 창조시가 낙조시보다 큰 유량을 나타내고 있다.

  • PDF

간이식에서 간동맥 문합술 (Hepatic artery anastomosis in liver transplantation)

  • 박명철;김치선;박동하;배남석;왕희정;김봉완
    • Archives of Plastic Surgery
    • /
    • 제36권1호
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: Liver transplantation is considered as the treatment of choice in many acute and chronic liver diseases, and it is becoming more common. Since successful microscopic anastomosis of hepatic artery is a crucial requirement of successful liver transplantation, we studied and analyzed the result of hepatic artery anastomosis of liver transplantation in our liver transplantation center. Methods: 145 liver transplantations were performed between February 2005 and May 2008. Male to female ratio of the liver transplantation recipients was 3.4 : 1. Anastomosis of portal vein, hepatic vein and biliary tract was performed by the general surgeon, and anastomosis of hepatic artery was performed by the plastic surgeon under the loupe or microscopic vision. After the hepatic artery was reconstructed, anastomosed site status and flow were checked with Doppler ultrasonography intraoperatively and with contrast enhanced CT or angiography postoperatively if necessary. Results: Out of 145 liver transplantations, cadaveric liver donor was used 37 cases and living donor liver transplantation was performed 108 cases including the 2 dual donor liver transplantations. As for the baseline diseases that resulted in the liver transplantation, there were 57 cases of liver cirrhosis and hepatocellular carcinoma due to hepatitis B, taking up the greatest proportion. Single donor hepatic artery was used in 114 cases, and mean artery diameter was 2.92 mm and mean artery length was 24.25 mm. Hepatic artery was used as the recipient artery in every case except the 8 cases in which gastroepiploic artery was used as alternative. Out of 145 cases of hepatic artery anastomosis, 3 cases resulted in the thrombosis of the hepatic artery, requiring thrombectomy and re - anastomosis. In all 3 cases, thrombosis was found in left hepatic artery and there was no past history of hepatic artery chemoembolization. Conclusion: Incidence of hepatic artery thrombosis after the anastomosis of hepatic artery during liver transplantation was 2.1%, which is considered sufficiently low.

개에서 건삭파열로 유발한 급성 이첨판 폐쇄부전 모델의 혈류역학적 평가 (Hemodynamic Evaluation of Acute Mitral Valve Insufficiency Model induced by Chordae Tendinae Rupture in Normal Dogs)

  • 김세훈;김남수;이기창;김종민;김민수
    • 한국임상수의학회지
    • /
    • 제31권5호
    • /
    • pp.367-370
    • /
    • 2014
  • 본 연구는 개에서 건삭파열로 유발한 급성 이첨판 폐쇄부전 모델의 혈류역학적 변화를 관찰하는 것이다. 이 연구는 10마리의 정상 심장기능을 가진 비글견에서 실시되었다. 직접혈압측정법과 Swan-Ganz 카테터를 통해 건삭을 실험적으로 파열시키는 기간동안 혈류역학적 지표 변화를 진행하였다. 이첨판 폐쇄부전 모델을 만들기 위해 5번 늑간으로 접근하여 관절경에 사용하는 작은 훅나이프를 사용하여 건삭을 파열하였다. 수술 중 칼라 도플러 영상 검사를 통해 이첨판 역류를 확인하였다. 혈류역학적 지표를 측정한 결과 폐모세혈관쇄기압은 유의적으로 증가하였지만, 평균동맥압, 정맥압, 폐동맥압, 심박출량, 심박출 지수는 건삭 파열 후에 유의적으로 감소한다는 것을 발견하였다. 이것은 건산파열로 인해 좌심실로 부터 역류된 혈액이 좌심방에 과부하를 일으킨다는 것을 나타내는 것이다. 본 연구를 통해 개에서 급성 이첨판 폐쇄부전 모델을 만드는데 있어 건삭파열방법이 효과적인 것을 알 수 있었고, 이첨판 역류 유발 후 시간이 지나면 만성 이첨판 부전증으로 진행할 수 있을 것으로 생각되며, 차후 판막의 만성적 변화 양상을 연구하는데 도움을 줄 수 있을 것으로 생각됩니다.

와전류 탐촉자를 이용한 총구 탄속 측정에 관한 연구 (Study on the Projectile Velocity Measurement Using Eddy Current Probe)

  • 신준구;손대락
    • 한국자기학회지
    • /
    • 제25권3호
    • /
    • pp.83-86
    • /
    • 2015
  • 무기체계가 첨단, 고도화되면서 탄약을 정밀 제어하여 목표를 타격하기 위하여 공중폭발탄(ABM)이 개발되어 전장에서 운용되고 있다. 이러한 공중폭발탄의 시한정밀도를 향상시키기 위하여 총구를 이탈하는 탄의 속도를 측정하여 표적까지의 정확한 비행시간을 계산한 후 탄에 입력하여야 한다. 본 연구에서는 K4 기관총의 소염기 부분에 탄을 감지할 수 있는 장치를 도입하였다. 탄약의 주요 금속 부품은 신관 부분의 알루미늄과 파편 효과를 발휘하는 탄체의 철 부분, 총열의 강선부를 통과할 때 직진운동을 회전운동으로 전환시키는 회전탄대의 구리로 구성되어 있는데 알루미늄 부분을 탐지하기 위하여 와전류 탐촉자의 원리를 도입하였다. 탄이 총구를 벗어나는 수십 us 동안 탄속을 측정하기 위하여 U 자형의 MnZn Ferrite 코어에 코일을 권선하여 200 kHz의 교류 전류를 인가하여 탄의 총구 이탈 속도를 측정하였으며, 도플러 레이더와 병행 계측한 결과 ${\pm}1%$ 이내에서 잘 일치하였다.

사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토 (Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel)

  • 손근수;유호준;김동수
    • 대한토목학회논문집
    • /
    • 제34권6호
    • /
    • pp.1753-1764
    • /
    • 2014
  • 하천의 흐름장을 모의하는 수치모형들은 연구 및 실무에서 다양한 목적의 유동해석에 광범위하게 활용되어오고 있다. 그러나, 수치모의 결과에 대한 검증은 현장 실측자료의 한계로 수리모형실험이나 매우 제한된 현장자료를 기반으로 수행되어 보다 정밀한 검증이 요구되어 왔다. 특히, 사행하천과 같이 기하학적 구조 및 흐름이 복잡한 형태를 갖는 경우는 수치모형이 얼마나 정확한 유속분포 모의를 할 수 있는지 알기 힘들었다. 최근, 초음파도플러유속계(ADCP) 등 최신 현장 계측기기의 발달로 하천 흐름의 정밀한 유속 및 하상 자료를 매우 효율적으로 측정 가능하게 되었다. 따라서, 기존 수치모형들을 실제 하천에서 공간적으로 정밀하게 측정된 유속자료를 기반으로 성능을 검증할 수 있는 기술적인 기반이 마련되었다고 할 수 있다. 이에 본 연구에서는 사행하천에서 정밀하게 측정된 ADCP 유속 자료를 기반으로 최근 국내에 도입된 FaSTMECH 모형을 대상으로 사행하천의 수위와 유속 분포 모의 결과를 검증하였다. 적용 구간은 한국건설기술연구원 하천실험센터의 폭 6.5 m, 평균수심 0.38 m, 유량 $1.54m^3/s$, 평균유속 0.61 m/s, 만곡도 1.2의 실규모 사행하천이다. FaSTMECH 모형의 적용성을 검토한 결과, 사행수로에 대한 수위 모의는 비교적 잘 일치하는 것으로 나타났으나, 만곡부에서 편향되는 횡방향 유속 분포를 잘 모의하지 못하는 것으로 나타났다.

미세술기를 이용한 정계정맥류절제술이 정자 핵 내 DNA Integrity에 미치는 효과 (Effect of Microsurgical Varicocelectomy on Human Sperm Nucleus DNA Integrity)

  • 김기영;이재석;지희준;김종현
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제37권3호
    • /
    • pp.245-251
    • /
    • 2010
  • 목 적: 인간 정자 핵 내의 DNA integrity는 배아의 발달 및 임신 유지에 중요한 역할을 하여 DNA integrity가 손상된 경우 불임과 유산의 원인이 된다고 하며, 정계정맥류는 DNA 손상을 일으키는 대표적인 원인 중 하나이다. 본 연구에서는 미세술기를 이용한 정계정맥류절제술로 정계정맥류를 교정을 하였을 때 정자 핵 내 DNA integrity가 어떠한 영향을 받는지에 대하여 알아보았다. 연구방법: 2006년 4월부터 2007년 4월까지 불임을 주소로 미세술기를 이용한 정계정맥류절제술을 받았던 18명의 환자에서 수술 전 후에 정액검사의 다른 지표들과 함께 정자 핵 내 DNA integrity가 어떻게 변화하였는지 조사하였다. 정자 핵 내 DNA integrity를 측정하는 방법으로 comet assay를 시행하였고, comet assay를 통한 DNA 손상 정도는 DNA fragmentation index (DFI)로 나타내었다. 결 과: 수술 후 4개월에 모든 환자에서 재발의 소견은 보이지 않았으며, DNA 손상 정도를 나타내는 평균 DFI는 수술 전에 19.3%, 수술 후에 13.7%로 유의한 변화를 보였다. 수술 전 DFI가 10 이상으로 비정상인 14명의 환자들 중 12명 (85%)에서 개선 소견을 보였으나, 수술 전 DFI가 10 미만인 정상 환자 4명에서는 1명 (25%)만이 개선 소견을 보였다. 수술 후 정자의 밀도, 운동성, 생존성에서 호전 양상을 보였으나 유의한 차이는 없었다. 결 론: 미세술기를 이용한 정계정맥류절제술을 통한 수술적 교정은 정액검사상의 다른 지표의 개선 뿐 아니라, 정자 핵 내 DNA 손상을 감소시킬 수 있다. 이상에서 정계정맥류의 수술적 교정으로 정자 핵 내 DNA integrity의 개선을 기대할 수 있으며, 이는 보다 양호한 정자를 많이 얻을 수 있어 자연임신이나 보조 생식술의 성공 가능성을 높일 수 있다는 점을 제시한다.

이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰 (Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid)

  • 정의성;성기웅;임형규;이장우;김동욱;이정현;김명남;조진호
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.