• Title/Summary/Keyword: Doppler center

Search Result 270, Processing Time 0.028 seconds

Iterative Detection and ICI Cancellation for MISO-mode DVB-T2 System with Dual Carrier Frequency Offsets

  • Jeon, Eun-Sung;Seo, Jeong-Wook;Yang, Jang-Hoon;Paik, Jong-Ho;Kim, Dong-Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.2
    • /
    • pp.702-721
    • /
    • 2012
  • In the DVB-T2 system with a multiple-input single-output (MISO) transmission mode, Alamouti coded orthogonal frequency division multiplexing (OFDM) signals are transmitted simultaneously from two spatially separated transmitters in a single frequency network (SFN). In such systems, each transmit-receive link may have a distinct carrier frequency offset (CFO) due to the Doppler shift and/or frequency mismatch between the local oscillators. Thus, the received signal experiences dual CFOs. This not only causes dual phase errors in desired data but also introduces inter-carrier interference (ICI), which cannot be removed completely by simply performing a CFO compensation. To overcome this problem, this paper proposes an iterative detection with dual phase errors compensation technique. In addition, we propose a successive-iterative ICI cancellation technique. This technique successively eliminates ICI in the initial iteration by exploiting pre-detected data pairs. Then, in subsequent iterations, it performs a fine interference cancellation using a priori information, iteratively fed back from the channel decoder. In contrast to previous works, the proposed techniques do not require estimates of dual CFOs. Their performances are evaluated via a full DVB-T2 simulator. Simulation results show that the DVB-T2 receiver equipped with the proposed dual phase errors compensation and the successive-iterative ICI cancellation techniques achieves almost the same performance as ideal dual CFOs-free systems, even for large dual CFOs.

Clinical Application of an Image-Guided Intervention in Three Dogs

  • Choi, Minsik;Kwon, Dohoon;Ahn, Jisoo;Ko, Minjung;Ahn, Jiyoung;Jung, Joohyun;Kim, Hakhyun;Kang, Ji-Houn;Chang, Dongwoo
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.100-105
    • /
    • 2020
  • A 9-month-old, 11.3 kg, intact, male, mixed-breed dog was referred for treatment of cor triatriatum dexter (CTD); a 5-month-old, 1.9 kg, intact, male Maltese for pulmonic stenosis (PS); and a 3-year-old, 6.62 kg, intact, female West Highland white terrier for esophageal stricture with regurgitation. A balloon catheter intervention was performed in the dog with CTD, and subsequent color Doppler ultrasound and abdominal ultrasound showed normal blood flow across the perforated membrane dividing the right atrium and the disappearance of the severe ascites present before treatment. Balloon catheter intervention in the dog with PS reduced the blood flow through the stenosis from 5.82 m/s to 3.97 m/s. In the dog with esophageal stricture, balloon catheter intervention widened the esophagus and no subsequent regurgitation was observed. Balloon catheter intervention is an interventional radiology procedure that represents a definitive treatment option for various stenotic lesions in dogs, including CTD, PS, and esophageal stricture. Although interventional radiology procedures for these diseases have already been reported, details of procedures and successful outcome have not been reported in Korea.

Structural Performance Tests of Down Scaled Composite Wind Turbine Blade using Embedded Fiber Bragg Grating Sensors

  • Kim, Sang-Woo;Kim, Eun-Ho;Rim, Mi-Sun;Shrestha, Pratik;Lee, In;Kwon, Il-Bum
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • In this study, the structural performance tests, i.e., static tests and dynamic tests of the composite wind turbine blade, were carried out by using the embedded fiber Bragg grating (FBG) sensors. The composite wind turbine blade used in the test is the 1/23 scale of the 750 kW composite blade. In static tests, the deflections along the blade were evaluated. Evaluations were carried out with simple beam theory and quadratic fitting method by using the embedded FBG sensors to predict the structural behavior with respect to the load. The deflections were compared to those obtained from the laser displacement sensor and electric strain gauges. They showed good agreement. Modal tests were performed to investigate the dynamic characteristics using the embedded FBG sensors. The natural frequencies obtained from the FBG sensors corresponding to the nine mode shapes of the blade were compared to those from the laser Doppler vibrometer. They were found to be consistent with each other. Therefore, it is concluded that the embedded FBG sensors have a great capability for measuring the structural performances of the composite wind turbine blade when structural performance tests are carried out.

DYNAMICAL CHARACTERISTICS OF SUNSPOT CHROMOSPHERES II. ANALYSIS OF CA II H, K AND ${\lambda}8498$ LINES OF A SUNSPOT (SPO 5007) FOR OSCILLATORY MOTIONS

  • Yoon, Tae-Sam;Yun, Hong-Sik;Kim, Jeong-Hoon
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.245-253
    • /
    • 1995
  • We have analyzed the time series of Ca II H,K and ${\lambda}8498$ line profiles taken for a sunspot (SPO 5007) with the Echelle spectrograph attached to Vacuum Tower Telescope at Sacramento Peak Solar Observatory. Each set of spectra was taken simultaneously for 20 minutes at a time interval of 30 seconds. A total of 40 photographic films for each line was scanned by a PDS at Korea Astronomy Observatory. The central peak intensity of Ca II H ($I_{max}$), the intensity measured at ${\Delta}{\lambda}=-0.1{\AA}$ from the line center of ${\lambda}8498(I_{{\lambda}8489})$, the radial velocity ($V_r$) and the Doppler width (${\Delta}{\lambda}_D$) estimated from Ca II H have been measured to study the dynamical behaviors of the sunspot chromosphere. Fourier analysis has been carried out for these measured quantities. Our main results are as follows: (1) We have confirmed the 3-minute oscillation being dominant throughout the umbra. The period of oscillations jumps from 180 sec in the umbra to 500 to 1000 sec in the penumbra. (2) The nonlinear character of the umbral oscillation is noted from the observed sawtooth shaped radial velocity fluctuations with amplitudes reaching up to $5{\sim}6\;km/sec$. (3) The spatial distribution of the maximum powers shows that the power of oscillations is stronger in the umbra than in the penumbra. (4) The spatial distributions of the time averaged < $I_{max}$ > and < $V_r$ > across the spot are found to be nearly axially symmetric, implying that the physical quantities derived from the line profiles of Ca II H and ${\lambda}8498$ are inherently associated with the geometry of the magnetic field distribution of the spot. (5) The central peaks of the CaII H emission core lead the upward motions of the umbral atmosphere by $90^{\circ}$, while no phase delay is found in intensities between $I_{max}$ and $I_{{\lambda}8498}$, suggesting that the umbral oscillation is of standing waves.

  • PDF

STUDY OF CORRELATION BETWEEN WETTED FUEL FOOTPRINTS ON COMBUSTION CHAMBER WALLS AND UBHC IN ENGINE START PROCESSES

  • KIM H.;YOON S.;LAI M.-C.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.437-444
    • /
    • 2005
  • Unburned hydrocarbon (UBHC) emissions from gasoline engines remain a primary engineering research and development concern due to stricter emission regulations. Gasoline engines produce more UBHC emissions during cold start and warm-up than during any other stage of operation, because of insufficient fuel-air mixing, particularly in view of the additional fuel enrichment used for early starting. Impingement of fuel droplets on the cylinder wall is a major source of UBHC and a concern for oil dilution. This paper describes an experimental study that was carried out to investigate the distribution and 'footprint' of fuel droplets impinging on the cylinder wall during the intake stroke under engine starting conditions. Injectors having different targeting and atomization characteristics were used in a 4-Valve engine with optical access to the intake port and combustion chamber. The spray and targeting performance were characterized using high-speed visualization and Phase Doppler Interferometry techniques. The fuel droplets impinging on the port, cylinder wall and piston top were characterized using a color imaging technique during simulated engine start-up from room temperature. Highly absorbent filter paper was placed around the circumference of the cylinder liner and on the piston top to collect fuel droplets during the intake strokes. A small amount of colored dye, which dissolves completely in gasoline, was used as the tracer. Color density on the paper, which is correlated with the amount of fuel deposited and its distribution on the cylinder wall, was measured using image analysis. The results show that by comparing the locations of the wetted footprints and their color intensities, the influence of fuel injection and engine conditions can be qualitatively and quantitatively examined. Fast FID measurements of UBHC were also performed on the engine for correlation to the mixture formation results.

Blood flow-improving activity of methyl jasmonate-treated adventitious roots of mountain ginseng

  • Ban, Young-Hwan;Cha, Yeseul;Choi, Jieun;An, Eun Suk;Lee, Ji Young;Han, Nu Ry;Seo, Da Woom;Jung, Gooyoung;Jeong, Da-Hye;Rhee, Man Hee;Choi, Ehn-Kyoung;Kim, Yun-Bae
    • Laboraroty Animal Research
    • /
    • v.33 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • insenosides from Panax ginseng are well known for their diverse pharmacological effects including antithrombotic activity. Since adventitious roots of mountain ginseng (ARMG) also contain various ginsenosides, blood flow-improving effects of the dried powder and extract of ARMG were investigated. Rats were orally administered with dried powder (PARMG) or ethanol extract (EARMG) of ARMG (125, 250 or 500 mg/kg) or aspirin (30 mg/kg, a reference control) for 3 weeks. Forty min after the final administration, carotid arterial thrombosis was induced by applying a 70% $FeCl_3$-soaked filter paper outside the arterial wall for 5 min, and the blood flow was monitored with a laser Doppler probe. Both PARMG and EARMG delayed the $FeCl_3$-induced arterial occlusion in a dose-dependent manner, doubling the occlusion time at high doses. In mechanism studies, a high concentration of EARMG inhibited platelet aggregation induced by collagen in vitro. In addition, EARMG improved the blood lipid profiles, decreasing triglyceride and cholesterol levels. Although additional action mechanisms remain to be clarified, it is suggested that ARMG containing high amount of ginsenosides such as $Rg_3$ improves blood flow not only by inhibiting oxidative thrombosis, but also by modifying blood lipid profiles.

Extraction of Blood Velocity Using FCM and Fuzzy Decision Trees in Doppler Ultrasound Images of Brachial Artery (상완동맥 색조 도플러 초음파 영상에서 FCM과 퍼지 의사 결정 트리를 이용한 혈류 속도 추출)

  • Kim, Kwang Baek;Jung, Young Jin;Nam, Youn Man;Lee, Jae Yeol
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.19-22
    • /
    • 2019
  • 상완동맥은 어깨에서부터 팔꿈치까지 내려오는 상완골의 내측부에 존재하며 혈압을 측정할 때 사용되는 혈관이다. 이 혈관은 골절로 인해 찢어지거나, 또는 혈액순환에 문제가 생겨 혈관이 막히는 경우가 발생한다. 이러한 경우 혈관의 상태를 확인하기 위하여 색조 도플러 초음파 검사를 사용하지만, 사용자에 따라 영상을 통한 판단 기준이 다르다는 문제점이 발생한다. 따라서 본 논문에서는 FCM과 Fuzzy Decision Tree를 이용한 영상 처리를 통해 일관성 있는 판단기준을 세우기 위한 혈류의 속도를 제안한다. 색조 도플러 초음파 영상에서의 상완 동맥을 추출하여 기울기를 이용한 FCM 알고리즘을 통해 소속도를 추출한 뒤 퍼지 룰에 적용하여 의사 결정 트리로 등급을 분류하고 결과적으로 혈류 속도를 추출한다. 색조 도플러 초음파 영상에서 환자의 개인 정보를 보호하기 위해 개인 정보 영역을 제거하여 ROI 영역을 추출하고 ROI 영역을 이진화를 통하여 상완동맥이 있는 영역을 추출한다. 이진화 된 ROI 영역에서 혈관 영상의 혈류 방향으로의 무게중심을 설정하고 각각의 픽셀과 무게중심 선과의 거리를 이용하여 소속도를 추출한 후 FCM을 사용하여 최적의 기울기를 선정한다. FCM을 통해 추출한 최종 소속도를 이용하여 퍼지 룰에 적용한 뒤 계산된 T-norm과 소속도의 분산을 이용하여 의사 결정 트리를 형성 트리의 단말 노드들은 각 픽셀을 분류한다. 분류되어진 데이터들의 노드별 소속도 평균을 구한 뒤 디퍼지화를 통해 COG(Center of Gravity)를 계산한다. 마지막으로 그 값을 이용하여 혈류 속도에 영향을 미치는 정도를 계산한 뒤 최종 혈류의 속도를 제안한다.

  • PDF

Venous malformations of the head and neck: A retrospective review of 82 cases

  • Park, Hannara;Kim, Jin Soo;Park, Hyochun;Kim, Ji Yoon;Huh, Seung;Lee, Jong Min;Lee, Sang Yub;Lee, Seok Jong;Lee, Joon Seok;Lee, Jeong Woo;Chung, Ho Yun
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.23-33
    • /
    • 2019
  • Background Venous malformations (VMs) are a common type of vascular malformation. However, their causes and management remain unclear, and few studies specific to VMs of the head and neck have been reported. This study describes our experiences with VMs of the head and neck. Methods This retrospective study included 82 patients who underwent treatment for head and neck VMs, among 222 who visited our vascular anomalies center. Medical records between 2003 and 2016 were reviewed to identify common features in the diagnosis and treatment. The diagnosis of suspected head and neck VMs was based on the results of imaging studies or biopsies, and the VMs were analyzed based on magnetic resonance imaging, computed tomography, and Doppler sonography findings. Results VMs were slightly more common in female patients (59.8%), and 45.1% of patients developed initial symptoms at the age of 10 or younger. Lesions were slightly more common on the right side (47.3%). The main sites involved were the cheek (27.7%) and lip area (25.5%). The muscle layer was commonly involved, in 98.7% of cases. Small lesions less than 5 cm in diameter accounted for 60.8% of cases, and well-defined types were slightly more prevalent at 55.4%. Improvement was observed in 77.1% of treated patients. Conclusions Early and accurate diagnosis and appropriate treatment according to individual symptoms are important for successful treatment of VMs. If treatment is delayed, the lesions can worsen, or recurrence becomes more likely. Therefore, VMs require a multidisciplinary approach for early and accurate diagnosis.

Estimation of Sejong VLBI IVP Point Using Coordinates of Reflective Targets with Their Measurement Errors (반사타겟 좌표 및 오차정보를 이용한 세종 VLBI IVP 위치계산)

  • Hong, Chang-Ki;Bae, Tae-Suk;Yi, Sangoh
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.717-723
    • /
    • 2020
  • Determination of local tie vectors between the space geodetic techniques such as VLBI (Very Long Baseline Interferometer), SLR (Satellite Laser Ranging), DORIS (Doppler Orbit determination and Radiopositioning Integrated on Satellite), GNSS (Global Navigation Satellite System) is essential for combination of ITRF (International Terrestrial Reference Frame). Therefore, it is required to compute IVP (Invariant Point) position of each space geodetic technique with high accuracy. In this study, we have computed Sejong VLBI IVP position by using updated mathematical model for adjustment computation so that the improvement on efficiency and reliability in computation are obtained. The measurements used for this study are the coordinates of reflective targets on the VLBI antenna and their accuracies are set to 1.5 mm for each component. The results show that the position of VLBI IVP together with its standard deviation is successfully estimated when they are compared with those of the results from previous study. However, it is notable that additional terrestrial surveying should be performed so that realistic measurement errors are incorporated in the adjustment computation process.

Screening of Anti-thrombotic Activity of Herbal Extracts in Ferric Chloride-induced Thrombosis Model (경동맥 혈전 유발 동물모델을 이용한 한약재 추출물의 효능 검색)

  • Park, In Sil;Lee, Ki Mo;Lee, In Sun;Han, Jae Il;Jeon, Won Kyung
    • The Korea Journal of Herbology
    • /
    • v.28 no.5
    • /
    • pp.33-38
    • /
    • 2013
  • Objectives : The aim of this study was to examine anti-thrombotic effect of traditional herbal extracts in a rat model of ferric chloride ($FeCl_3$)-induced carotid arterial thrombosis. Methods : Thirty minutes prior to a 35% $FeCl_3$ application, Sprague Dawley(SD) rats were injected with the 10 types of traditional herbal extracts (100mg/kg, intraperitoneal injection), respectively. The effect of these herbal extracts was examined for time to occlusion(TTO) using the Laser doppler flow meter and measured for thrombus weight (TW) in $FeCl_3$-induced thrombosis model. Results : In the TTO, Salvia miltiorrhiza (Sm, $2.30{\pm}0.28$ min, p<0.001) and Santalum album (Sa, $2.19{\pm}0.19$ min, p<0.001) showed significantly delayed TTO more than twice compared with Saline-treated group. Cnidium officinale (Co), Psoralea corylifolia (Pc), Scutellatia baicalensis (Sba), Panax notoginseng (Pn), Angelica tenuissima (At), Scrophularia buergeriana (Sbu), Rhus verniciflua (Rv) and Picrasma quassioides (Pq), except for Rhus verniciflua (Rv) also meaningfully impeded TTO more than one fold. In addition, Salvia miltiorrhiza, Santalum album, Cnidium officinale, Psoralea corylifolia and Scutellatia baicalensis significantly reduced TW more than 10% compared with Saline-treated group. Especially, Salvia miltiorrhiza and Santalum album showed the most excellent anti-thrombotic effect among the 10 herbal extracts tested on the restoration of altered TTO and TW. Conclusions : These results suggest that Sm and Sa extracts have outstanding anti-thrombotic effect in $FeCl_3$-induced thrombosis model and is potentially useful as herbal medicines for the treatment and prevention of thrombosis.