• Title/Summary/Keyword: Doppler center

Search Result 272, Processing Time 0.025 seconds

Analysis of Transceiver Structure and Experimental Results of Underwater Acoustic Communication Using the Sub-band (부 대역을 이용한 수중 음향 통신 송수신 구조 및 실험 결과 분석)

  • Jeong, Hyun-Woo;Shin, Ji-Eun;Jung, Ji-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.545-555
    • /
    • 2020
  • This paper presented efficient transceiver structure using sub-band processing for underwater communication in terms of covertness and performance improvement. In aspect of covertness, encrypted coded-bits are divided into groups, and center frequency and sub band are determined by coded-bits of each group. Therefore, as center frequencies are changed randomly, it maintain the covertness effectively. In aspect of performance improvement, the performance of underwater communication mainly depends on multi-path propagation characteristics, Doppler-spread, and frame synchronization. Accordingly, in order to overcome these effects, non-coherent energy detector and turbo equalization method are employed in receiver side. Furthermore, optimal frame synchronization was proposed. Through the simulation and lake experiment, performance analysis was conducted. Especially in the lake experiment, as a result of applying optimal frame synchronization method to receiver structure, errors are corrected in most frames.

Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysms

  • Hyoung-Ho Kim;Kyung-Wuk Kim;Changje Lee;Young Ho Choi;Min Uk Kim;Yasutaka Baba
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1834-1840
    • /
    • 2021
  • Objective: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. Materials and Methods: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. Results: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. Conclusion: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.

Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

  • Lee, Ji Seong;Chee, Hyun Keun;Kim, Jun Seok;Song, Myong Gun;Park, Jae Bum;Shin, Je Kyoun
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.328-334
    • /
    • 2015
  • Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, $47.7{\pm}9.7years$; 11 female and 4 male) who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was $13.5{\pm}7years$. The mean preoperative Wilkins score was $9.4{\pm}2.6$. Results: The mean mitral valve area obtained using planimetry increased from $1.16{\pm}0.16cm^2$ to $1.62{\pm}0.34cm^2$ (p=0.0001). The mean pressure half time obtained using Doppler ultrasound decreased from $202.4{\pm}58.6ms$ to $152{\pm}50.2ms$ (p=0.0001). The mean pressure gradient obtained using Doppler ultrasound decreased from $9.4{\pm}4.0mmHg$ to $5.8{\pm}1.5mmHg$ (p=0.0021). There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period ($39{\pm}16months$). The 5-year event-free survival was 56.16% (95% confidence interval, 47.467-64.866). Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

DYNAMICAL CHARACTERISTICS OF THE QUIET TRANSITION REGION: SPATIAL CORRELATION STUDIES OF H I 931 AND S VI 933 UV LINES

  • YUN HONG SIK;CHAE JONG CHUL;POLAND A. I.
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.1
    • /
    • pp.1-17
    • /
    • 1998
  • To understand the basic physics underlying large spatial fluctuations of intensity and Doppler shift, we have investigated the dynamical charctersitics of the transition region of the quiet sun by analyzing a raster scan of high resolution UV spectral band containing H Lyman lines and a S VI line. The spectra were taken from a quiet area of $100'\times100'$ located near the disk center by SUMER on board SOHO. The spectral band ranges from 906 A to 950 A with spatial and spectral resolution of 1v and $0.044 {\AA}$, respectively. The parameters of individual spectral lines were determined from a single Gaussian fit to each spectral line. Then, spatial correlation analyses have been made among the line parameters. Important findings emerged from the present analysis are as follows. (1) The integrated intensity maps of the observed area of H I 931 line $(1\times10^4 K)$ and S VI 933 line $(2\times10^5 K)$ look very smilar to each other with the same characterstic size of 5". An important difference, however, is that the intensity ratio of brighter network regions to darker cell regions is much larger in S VI 933 line than that in H I 931 line. (2) Dynamical features represented by Doppler shifts and line widths are smaller than those features seen in intensity maps. The features are found to be changing rapidly with time within a time scale shorter than the integration time, 110 seconds, while the intensity structure remains nearly unchanged during the same time interval. (3) The line intensity of S VI is quite strongly correlated with that of H I lines, but the Doppler shift correlation between the two lines is not as strong as the intensity correlation. The correlation length of the intensity structure is found to be about 5.7' (4100 km), which is at least 3 times larger than that of the velocity structure. These findings support the notion that the basic unit of the transition region of the quiet sun is a loop-like structure with a size of a few $10^3 km$, within which a number of unresolved smaller velocity structures are present.

  • PDF

Change of Cerebral Blood Flow during Tilt Tests in Children with Vasovagal Syncope (혈관미주 신경성 실신 소아에서 기립경사 검사 동안에 뇌혈류 변화)

  • Kim, Su Jung;Yom, Hye Won;Hong, Young Mi;Yoo, Jung Hyen;Lee, Sook Hee;Kim, Chong Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.983-988
    • /
    • 2003
  • Purpose : Syncope appears to be common. However, the mechanism of syncope is not clear. Increased vagal activity and withdrawal of sympathetic stimulation cause hypotension, bradycardia and finally loss of consciousness. The purpose of this study was to evaluate changes of cerebral blood flow velocity, blood pressure, and heart rate during tilt test in children with vasovagal syncope. Methods : Sixty four children with a past history of syncope were evaluated. The stand up test was performed for 15 minutes after a rest at supine position for 10 minutes, followed by an $80^{\circ}$ tilt test lasting 45 minutes. If presyncope(lightheadedness, nausea, blurred vision, or sweating) or syncope occurred, the study was discontinued. 12-lead electrocardiography, echocardiography, and electroencephalography were performed. Transcranial Doppler study was performed at the middle cerebral artery with 2 MHz continuous Doppler probe in 10 children with positive tilt test. Systolic, diastolic, mean cerebral blood flow velocity, integral, and pulsatility index were measured with blood pressure, heart rate, and $O_2$ saturation. Results : The positive rate of tilt test was 31.3%(20/64). Systolic, diastolic, and mean cerebral blood flow velocity decreased significantly in absence of hypotension or bradycardia during presyncope. Time velocity integral of cerebral artery also decreased significantly. Conclusion : Decreased cerebral blood flow velocity can predict the presyncope manifestation. Impairment of autoregulation of cerebral blood flow might play an important role in the pathophysiology of vasovagal syncope.

Elbow Pain Brought on by a Minuscule Angioleiomyoma (아주 작은 혈관평활근종에 의해 야기된 팔꿈치 통증)

  • Jo, Won-Jae;Lee, Kwang-Jae;Yoo, Seol-Bong;Yoon, Yong-Soon;Choi, Jun-Hyun
    • Clinical Pain
    • /
    • v.19 no.1
    • /
    • pp.45-48
    • /
    • 2020
  • Angioleiomyoma is an infrequent benign smooth muscle tumor that arises from smooth muscle cells of arterial or venous walls in the tunica media layer. It would be found in the dermis, the subcutaneous tissue, or the superficial fascia of the anywhere in the body and is most often seen in the lower extremities. The typical lesion is a small, slowly growing, round, but firm and mobile nodule. We report a case of angioleiomyoma located on the anterior aspect of the elbow, which was mistaken for extradigital glomus tumor after history taking, physical examination. With point tenderness and worsening sharp pain in cold exposure for several years, the patient was referred for a further evaluation, and the lesion was 5 mm sized well-circumscribed mass in the anterior elbow with vascular signals on color and power Doppler by ultrasonography and finally diagnosed as angioleiomyoma following complete excision and histological evaluation.

The Diagnostic Accordance between Transcranial Doppler and MR Angiography in the Intracranial Artery Stenosis (두개강내 혈관 협착에 대한 경두개도플러와 자기공명 혈관조영술의 일치도 평가)

  • Moon, Sang-kwan;Jung, Woo-sang;Park, Sung-uk;Park, Jung-mee;Ko, Chang-nam;Cho, Ki-ho;Bae, Hyung-sup;Kim, Young-suk;Cho, Seong-il
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.7 no.1
    • /
    • pp.11-16
    • /
    • 2006
  • Objectives : Transcranial Doppler (TCD) has been reported to be established as useful in detecting spasm after subarachnoid hemorrhage and to be probably useful in diagnosing stenosis or occlusion in intracranial arteries. In the detection of intracranial stenosis using TCD there have been reported some kinds of diagnostic criteria. This study was aimed to evaluate the accordance between TCD and magnetic resonance angiography (MRA) in detection of intracranial stenosis and to find out more accurate criteria for intracranial stenosis using TCD. Methods : Seventy-six stroke patients were evaluated by TCD and MRA. TCD criteria for middle cerebral artery (MCA) stenosis were used by 3 methods; ≥ 80cm/sec of mean velocity(Vm), ≥ 140 cm/sec of systolic velocity(Vs), and both. For stenosis of vertebral(VA) and basilar arteries(BA), the TCD criteria followed by 2 methods; ≥ 70 cm/sec of Vm and ≥ 100 cm/sec of Vs. The stenosis of intracranial artery in MRA followed by the interpretation of specialist in the department of radiology. The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and kappa agreement were calculated in each criteria of TCD compared with the result of MRA. Results : The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and kappa agreement using ≥ 80cm/sec of Vm for MCA stenosis were 55.6%, 81%, 34.5%, 91.0%, 77.1%, and 0.293, respectively. Using 140 cm/sec of Vs, those were 44.4%, 92.0%, 50.5%, 90.2%, 84.7%, 0.380, and using both criteria those were 44.4%, 95.0%, 61.5%, 90.5%, 87.3%, 0.445, respectively. Those using ≥ 70 cm/sec of Vm for VA and BA stenosis were 71.4%, 93.7%, 26.3%, 99.0%, 93.0%, 0.186 and using ≥ 100 cm/sec of Vs those were 71.4%, 97.3%, 45.5%, 99.1%, 96.5%, 0.539, respectively. Conclusion : These results suggested that for the diagnosis of MCA stenosis using TCD we should use the criteria of both ≥ 80cm/sec of Vm and 140 cm/sec of Vs, and for the VA and BA stenosis we adapt the criteria of ≥ 70 cm/sec of Vm.

  • PDF

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.3
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

The Effect of Slider Surface Texture on Flyability and Lubricant Migration under Near Contact Conditions

  • Zhou, L.;Kato, K.;Vurens, G.;Talke, F.E.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.277-278
    • /
    • 2002
  • Magnetron and Ion beam sputtering were used to texture the air-bearing surface of magnetic recording sliders. Flying height measurements and Laser-Doppler interferometry were used to compare the 'flyability' of textured and untextured sliders. Lubricant redistribution on the disk surface caused by slider/disk interactions was investigated using scanning ellipsometry (Surface Reflectance Analyzer (SRA)). The results show that slider surface texture causes only small changes in the flying height of sliders but reduces slider in-plane and out-of-plane vibrations. Textured sliders were found to cause less lubricant depletion on the disk surface than untextured sliders.

  • PDF

Analysis of Integrated Navigation Performance for Sensor Selection of Unmanned Underwater Vehicle (UUV) (무인잠수정 센서 선정을 위한 복합항법 성능 분석)

  • Yoo, Tae-Suk;Kim, Moon Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.566-573
    • /
    • 2014
  • This paper presents the results of an integrated navigation performance analysis for selecting the sensor of an unmanned underwater vehicle (UUV) using Monte Carlo numerical simulation. An inertial measurement unit (IMU) and Doppler velocity log (DVL) are considered to build the integrated navigation system. The position error and price of the sensor are selected as performance indices to evaluate the volunteer integrated navigation systems. Monte-Carlo simulation is introduced to analyze the circular error probability (CEP) and its variance. Simulation results provide the proper sensor combination for integrated navigation in relation to the performance and price.