• Title/Summary/Keyword: Doppler US

Search Result 48, Processing Time 0.026 seconds

Exclusion zones for GNSS signals when reconfiguring receiver hardware in the presence of narrowband RFI

  • Balaei, Asghar T.;Dempster, Andrew G.;Barnes, Joel
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.347-352
    • /
    • 2006
  • Narrowband interference can severely degrade the performance of GPS receivers. Detecting the presence of interference and then characterizing it can lead to its removal. Receivers can be reconfigured to focus on other signals or satellites that are less vulnerable to that interference at that moment. Using hardware reconfigurability of FPGA receivers and characterizing the effect of narrowband interference on the GNSS signal quality lead us to a new RFI mitigation technique in which the highest quality and less vulnerable signal can be chosen at each moment. In the previous work [1], the post processing capability of a software GPS receiver, has been used to detect and characterize the CW interference. This is achieved by passing the GPS signal and the interference through the correlator. Then, using the conventional definition of C/No as the squared mean of the correlator output divided by its variance, the actual C/No for each satellite is calculated. In this work, first the 'Exclusion zone' for each satellite signal has been defined and then by using some experiments the effects of different parameters like signal power, jamming power and the environmental noise power on the Exclusion zone have been analyzed. By monitoring the Doppler frequency of each satellite and using the actual C/No of each satellite using the traditional definition of C/No and actual data from a software GPS receiver, the decision to reconfigure the receiver to other signal can be made.

  • PDF

Endovascular Treatment of Congenital Portosystemic Shunt: A Single-Center Prospective Study

  • Ponce-Dorrego, Maria-Dolores;Hernandez-Cabrero, Teresa;Garzon-Moll, Gonzalo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.2
    • /
    • pp.147-162
    • /
    • 2022
  • Purpose: To design a prospective study on endovascular closure of congenital portosystemic shunts. The primary endpoint was to assess the safety of endovascular closure. The secondary endpoint was to evaluate the clinical, analytical and imaging outcomes of treatment. Methods: Fifteen patients (age range: 2 days to 21 years; 10 male) were referred to our center due to congenital portosystemic shunts. The following data were collected prior to treatment: age, sex, medical history, clinical and analytical data, urine trimethylaminuria, abdominal-US, and body-CT. The following data were collected at the time of intervention: anatomical and hemodynamic characteristics of the shunts, device used, and closure success. The following data were collected at various post-intervention time points: during hospital stay (to confirm shunt closure and detect complications) and at one year after (for clinical, analytical, and imaging purposes). Results: The treatment was successful in 12 participants, migration of the device was observed in two, while acute splanchnic thrombosis was observed in one. Off-label devices were used in attempting to close the side-to-side shunts, and success was achieved using Amplatzer™ Ductus-Occluder and Amplatzer™ Muscular-Vascular-Septal-Defect-Occluder. The main changes were: increased prothrombin activity (p=0.043); decreased AST, ALT, GGT, and bilirubin (p=0.007, p=0.056, p=0.036, p=0.013); thrombocytopenia resolution (p=0.131); expansion of portal veins (p=0.005); normalization of Doppler portal flow (100%); regression of liver nodules (p=0.001); ammonia normalization (p=0.003); and disappearance of trimethylaminuria (p=0.285). Conclusion: Endovascular closure is effective. Our results support the indication of endovascular closure for side-to-side shunts and for cases of congenital absence of portal vein.

The Relationship between Carotid Intima-Media Thickness and 24-hour Ambulatory ECG in Ischemic Stroke Patients (뇌경색 환자의 경동맥 초음파 검사와 24시간 홀터 검사와의 연관성 연구)

  • Kang, Ji-Suck;Park, Sung-Hwan;Song, Moon-Koo;Ahn, Young-Min;Ahn, Se-Young;Lee, Byung-Cheol
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.2
    • /
    • pp.422-430
    • /
    • 2009
  • Background : Stroke is the second leading cause of death in Korea, following cancer. Stroke consists of ischemic and hemorrhagic stroke, and ischemic stroke can be largely classified as atherothrombotic stroke or embolic stroke. Carotid intima-media thickness (IMT) is an indicator of atherosclerosis used commonly as a screening test for abnormalities of the coronary artery. 24-hour ambulatory ECG is widely used to screen for underlying diseases that causes syncope, palpitation, arrhythmia, etc. Objectives : Since both carotid IMT and 24-hour ambulatory ECG are used to screen for cardiac problems, we endeavored to explore the correlation between carotid IMT and 24-hour ambulatory ECG of stroke patients. Methods : The records of ischemic stroke patients who were admitted to Kyunghee Medical Center Oriental Hospital ward from March 2006 to May 2009 were reviewed. 28 patients who had both carotid Doppler US and 24-hour ambulatory ECG test undertaken during their admission were analyzed. The relationship of abnormal ambulatory results and common carotid artery(CCA) IMT were statistically analyzed using Fisher's exact test and t-test. Results : The mean age of the abnormal ambulatory group was older than the normal group (74${\pm}$ 8.0 vs. 61${\pm}$12.1, p=0.0098). Although insignificant, the abnormal ambulatory group showed much thicker CCA-IMT than normal ambulatory group (2.l7${\pm}$ 1.16 vs. 1.51${\pm}$0.97. p=0.l389). Conclusion: No significant correlation was observed between abnormal ambulatory results and CCA-IMT. However, the difference in CCA-IMT between the two groups was too big to be ignored and further investigation with larger and better controlled trials are warranted.

  • PDF

A Study on the Correlation Results for Fringe Rotation and Delay Tracking of the VCS (VCS의 지연추적과 프린지 회전에 대한 상관결과 고찰)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Oh, ChungSik;Jung, Jin-Seung;Chung, Dong-Kyu;Oyama, Tomoaki;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Kono, Yusuke;Ozeki, Kensuke;Onuki, Hirohumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.220-232
    • /
    • 2012
  • In this paper, we investigate the correlation result due to the problems of delay tracking and fringe rotation module in the VCS(VLBI Correlation Subsystem). The VCS, FX-type correlator, adopts the delay tracking and fringe rotation module in order to compensate the delay change and fringe phase of wave signal from the radio source by Doppler's effect. The phase of observed data is also compensated by means of delay tracking and fringe rotation in the correlator, but we confirmed that the phase is unstable by applying long integration period of AIPS(Astronomical Image Processing System) rather than correlator. And the delay value of observed data has the errors of several tens nanoseconds than normal case at the analysis of correlation result. In addition, we found that the phase of correlation results is not connected as the unit of FFT-segment because the initial fringe phase at the fringe rotation module is not correctly determined. In this paper, in order to solve these problems, the original direction of 90 degree phase jump is reversely modified when the bit-shift occurred at the delay tracking. And the initial fringe phase at the fringe rotation module is correctly modified by using the initial phase of observed data. In addition, the parameter calculation module was abnormally operated as designed in the fringe rotation. So, the logical program by the VCS is modified so as to calculate the parameters correctly. Through the experiments of correlation processing over the above problems, the modified proposal algorithm is adequately corrected to the data analysis results, so that the experimental results make it clear for us to operate the developed VCS hardware correlator normally.

Study on the Projectile Velocity Measurement Using Eddy Current Probe (와전류 탐촉자를 이용한 총구 탄속 측정에 관한 연구)

  • Shin, Jungoo;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.83-86
    • /
    • 2015
  • Nowadays the weapon systems are employed air bursting munition (ABM) as smart programmable 40 mm shells which have been developed in order to hit the target with programmed munition that can be air burst after a set distance in the battlefield. In order to improve the accuracy of such a bursting time, by measuring the speed of the munition from the barrel, weapon systems calculate the exact time of flight to the target and then the time information must be inputted to the munition. In this study, we introduce a device capable of detecting a shot at K4 40 mm automatic grenade. The shot is composed of a rotating copper band to convert linear motion into rotary motion when it passes through the barrel, the steel section is exert the effect of fragment and aluminum section to give fuze information. The aluminum section was used to detect munition using eddy current method. To measure muzzle velocity by means of non-contact method, two eddy current probes separated 10 cm was employed. Time interval between two eddy current probe detection times was used as muzzle velocity. The eddy current probe was fabricated U-shape Mn-Zn ferrite core with enamelled copper wire, and 200 kHz alternating current was used to detect inductance change. Measured muzzle velocity using the developed sensor was compared to the Doppler radar system. The difference was smaller than 1%.

Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel (사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토)

  • Son, Geunsoo;You, Hojun;Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1753-1764
    • /
    • 2014
  • Numerical flow simulation models in the riverine environments have been widely utilized for analyzing flow dynamics in various degrees in researches and practical applications. However, most of the simulated results have been validated based on the data from indoor experimental models or very limited in-situ measurements. Therefore, it has been required to more accurately validate the performance of the numerical models in terms of the detailed field observations. In particular, it was also hard to validate the performances of the existing numerical models in the real meandered river channels that encompass more sophisticated flow and geometric structures. Recently, advancements of the modern flow measuring instrumentations such as acoustic Doppler current profilers (ADCPs) enabled us to efficiently acquire the detailed flow field in the broad range of river channels, thus that it became to be possible to accurately validate any numerical models with the field observations. In this study, based on the detailed flow measurements in a actual meandered river channel using ADCP, we validated FaSTMECH model in iRIC in terms of water surface elevation, which is relatively new but began to get highlighted in the research areas. As the validation site, a meandering channel in River Experiment Center of KICT was chosen, which has 6.5 m of width, 0.38m of flow depth, 1.54 m3/s of flow discharge, 0.61 m/s of mean flow velocity, and 1.2 of sinuosity. As results, whereas the FaSTMECH precisely simulated water surface elevation, simulated velocity field in the bend did not match well with ADCP dataset.

MINERVA: SMALL PLANETS FROM SMALL TELESCOPES

  • WITTENMYER, ROBERT A.;JOHNSON, JOHN ASHER;WRIGHT, JASON;MCCRADY, NATE;SWIFT, JONATHAN;BOTTOM, MICHAEL;PLAVCHAN, PETER;RIDDLE, REED;MUIRHEAD, PHILIP S.;HERZIG, ERICH;MYLES, JUSTIN;BLAKE, CULLEN H.;EASTMAN, JASON;BEATTY, THOMAS G.;LIN, BRIAN;ZHAO, MING;GARDNER, PAUL;FALCO, EMILIO;CRISWELL, STEPHEN;NAVA, CHANTANELLE;ROBINSON, CONNOR;HEDRICK, RICHARD;IVARSEN, KEVIN;HJELSTROM, ANNIE;VERA, JON DE;SZENTGYORGYI, ANDREW
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.665-669
    • /
    • 2015
  • The Kepler mission has shown that small planets are extremely common. It is likely that nearly every star in the sky hosts at least one rocky planet. We just need to look hard enough-but this requires vast amounts of telescope time. MINERVA (MINiature Exoplanet Radial Velocity Array) is a dedicated exoplanet observatory with the primary goal of discovering rocky, Earth-like planets orbiting in the habitable zone of bright, nearby stars. The MINERVA team is a collaboration among UNSW Australia, Harvard-Smithsonian Center for Astrophysics, Penn State University, University of Montana, and the California Institute of Technology. The four-telescope MINERVA array will be sited at the F.L. Whipple Observatory on Mt Hopkins in Arizona, USA. Full science operations will begin in mid-2015 with all four telescopes and a stabilised spectrograph capable of high-precision Doppler velocity measurements. We will observe ~100 of the nearest, brightest, Sun-like stars every night for at least five years. Detailed simulations of the target list and survey strategy lead us to expect $15{\pm}4$ new low-mass planets.

Clinical Observations of 30 Children with Nutcracker Syndrome (Nutcracker 증후군 환아 30례에 대한 임상적 고찰)

  • Lee Dong Woo;Juhn Ji Hyun;Lee Jae Seung;Kim Myung Joon
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2001
  • Purpose : This study was undertaken to investigate clinical aspects of nutcracker syndrome in children including sexual distribution, age of onset, the ratio of peak flow velocity between the narrowed and dilated portions in the left renal vein and prevalence of hematuria or proteinuria. Materials and Method : The subjects included 30 patients diagnosed with nutcracker syndrome using Doppler sonography from September 1999 to January 2001 in Severance Hospital, Department of Pediatric Nephrology. The diagnostic criteria for nutcracker syndrome was a peak flow velocity of ratio is more than 5.0. Results : Patients consisted of 14 males and 16 females. The mean age was 9.19${\pm}$2.31 years old and the ratio of peak flow velocity was 8.52${\pm}$2.24. Age of onset us higher in males 9.68${\pm}$2.82 year old than in females, 8.76${\pm}$1.72 year old respectively(P<0.05). But there was no difference in the ratio of peak flow velocities ; 8.45${\pm}$2.31 in the male group , 8.58${\pm}$2.25 in the female group(P>0.05). There was no difference in the age of onset and the ratio of peak flow velocity between patients with hematuria and without hematuria. Among patients with nutcracker syndrome, 24 cases of hematuria, 3 cases of proteinuria only, and 3 cases of hematuria with proteinuria. Conclusion : In children of school age, early diagnosis of nutcracker syndrome and consistent follow up is worthy of consideration, especially ill the prevention of sequelae. (J. Korean Soc Pediatr Nephrol 5 : 9-14, 2001)

  • PDF