• Title/Summary/Keyword: Door-opening

Search Result 202, Processing Time 0.027 seconds

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF

Dynamical Mechanism Analysis of An Industrial Two-step Folding Automatic Door (2단 접이식 산업용 자동문의 동역학적 메카니즘 해석)

  • Yun, Seong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.821-826
    • /
    • 2011
  • This paper deals with an analysis of dynamic mechanism for the industrial two-step folding automatic door. A nonlinear equation of motion was derived in terms of folding angle to estimate driving forces. Based on this dynamic behavior, time taken during the door's opening well as their velocities were controlled so that the operating conditions can be obtained for the purpose of design. The stiffness of twisting spring was also investigated when the automatic door closed, because a dangerous accident takes place from the door's free falling. The current research will be a very useful tool in the near future for the dynamic analysis for the multi-step folding automatic door.

Development of an Automatic Face Velocity Controller for a Fume Hood System (흄후드 시스템의 면 풍속 자동 제어기 개발)

  • Kim, Hogeol;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.304-309
    • /
    • 2013
  • In chemical, medical or biology laboratories Fume Hoods are basic facilities which can protect researchers from dangerous gas as blowing the contaminated air outside. After the air inside the laboratory room is sucked into the hume hood, then, it is blew out by a fan rotated by an AC induction motor. In addition, a damper controls the inside opening of a duct, which the air flows through. The face velocity, air velocity through the front door, have to be kept constant as the set value even though the opening of the door is varied. However, conventional fume hood used to be operated by operator's manual switches. So that, in this paper an automatic control system is developed which controls the face velocity by adjusting the rotating speed of the blow motor and the opening of the damper. Experiments show that this developed system can be used at such laboratories.

Evaluation of Twisting Deformation of the Door Frame of a Microwave Oven by Transient Response Analysis (과도응답 해석에 의한 전자레인지 도어 프레임의 비틀림 변형 평가)

  • Koo, Jin-Young;Lee, Boo-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.9 s.240
    • /
    • pp.1282-1288
    • /
    • 2005
  • This research has been motivated by the need to minimize possible leakage of microwave when one opens the door during operation of the microwave oven. An explicit finite element program is used to analyze the transient response the door of the oven under door-opening condition. Operation of the micro switch which plays an important role to hun off the power is simulated on the basis of the response of the latch. Using the results of the analysis, twisting deformation of the door frame is defined and evaluated.

Analysis of Thermal Characteristics for Components of Electrical Door System in Electric Multiple Unit (전동차 전기식 도어시스템의 구성부품에 대한 발열 특성분석)

  • Lee, Bon Hyung;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.18-24
    • /
    • 2020
  • This research conducted an the failure analysis was performed based on the failure and operation data for Seven years using the Reliability, Availability, Maintainability, and Safety(RAMS) constructed at the operation stage after the opening of the D urban railway. therefore, the risk priority was selected for failure frequency component within the door system that showed high failure. Finally, the goal was to suggest ways to improve the door system. For this purpose, the analysis of thermal characteristics of failed components such as Door Control Unit(DCU) in the door system based on the Seven-year failure analysis data of RAMS was performed. These results were applied to the main component exchange cycle of the door unit, the mean time between failure(MTBF) and mean kilometer between failure(MKBF) values of RAMS increased by 26% in 2017-2018 when the improvement measures were taken, and the MTBF value of DCU was 300,000 hours, which was a 57% improvement in reliability. The results of this thesis identify potential enhancements in reliability and improvements in maintenance of the door system that, if implemented, would contribute to train safety and reduce instances of failure in the future.

A Study on the Reinforcement Method of the Door Lock Box Frame for Easy Field Processing Assembly in Steel Door (강철재도어에서 현장가공조립이 용이한 도어락상자틀 보강방법에 대한 연구)

  • Iim, Bo-Hyuk;Lee, Joo-Won;Cho, Seong-Gwon;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.133-134
    • /
    • 2023
  • In general, all buildings are equipped with various types of handles for opening and closing the door, and unlike wooden doors, steel doors such as fire doors are equipped with a box-shaped door lock box frame surrounding the outside of the door lock to protect the door lock, which is called a cylinder protection cover. These cylinder protection covers have various types and types of fastening structures, and the cylinder protection covers on the market are molded in factories and standardized according to the size and shape of the door lock, requiring various types of cylinder protection covers. Accordingly, a variable cylinder protection cover with a simple prefabricated structure that can fundamentally solve these problems can be used as one cylinder protection cover regardless of the type, shape, and size of the door lock.

  • PDF

Pressure Differentials in the Elevator Lobby Depending on the Evacuation Scenarios (피난 시나리오에 따른 승강장 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • The aim of this paper is to investigate the change of pressure differential and smoke propagation characteristics in the elevator lobby with the resident's evacuation scenarios using fire modelling technique. The results showed absolute pressures in the fire room and elevator lobby can significantly increase to cause fire door to the stairway unclosed once it is open. This is due to constant pressure differentials, the increasing reference pressure of fire lobby and pressure leak from elevator lobby to fire lobby. Smoke exhaust mechanism was needed to prevent the continuous pressure rise in the living room. Over 200 Pa was expected upon closing the door during pressurization, which provide difficulties in opening the door for next refugee. Opening both fire door and entrance door may induce smoke flow from fire room to elevator lobby and stairway.

Prediction of Assistance Force for Opening/Closing of Automobile Door Using Support Vector Machine (서포트 벡터 머신을 이용한 차량도어의 개폐 보조력 예측)

  • Yang, Hac-Jin;Shin, Hyun-Chan;Kim, Seong-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.364-371
    • /
    • 2016
  • We developed a prediction model of assistance force for the opening/closing of an automobile door depending on the condition of the parking ground. The candidates of the learning models for the operating assistance force were compared to determine the proper force according to the slope and user's force, etc. The reduced experimental model was developed to obtain learning data for the estimation model. The learning algorithm was composed to predict the assistance force to incorporate real assistance force data. Among these algorithms, an Artificial Neural Network (ANN) and Support Vector Machine(SVM) were applied and the adaptability was compared between these models. The SVM provided more adaptability for the learning process of the door assistance force prediction. This paper proposes a system for determining the assistance force to control a door motor to compensate for the deviation of required door force in the slope condition, as needed in the plane condition.

A Study on the Collision Detection for Smart Door by Disturbance Observer (외란관측기를 이용한 스마트도어의 충돌감지에 관한 연구)

  • Park, Min-Kyu;Sung, Kum-Gil;Lee, Byungsoo
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.31-36
    • /
    • 2011
  • Smart Door(SD) is a human friendly power-assisted door system for passenger car doors. It offers comfort and safety to passengers and drivers by supplying additional power. In this study, dynamic system model and the equation of motion derivation are derived. And we propose the disturbance observer based collision detection algorithm for safety when opening the door. A disturbance caused by collision has a fast response compared to a friction, uncertainties and so on. The main idea this study is to estimate a variation of disturbance for stably and effectively detecting a collision. In order to evaluate a performance of collision detection, an experiment set up is constructed. The experimental results validate the usefulness of the proposed collision detection algorithm.

Interference-free French door design using four-bar linkage mechanism (4절 링크를 이용한 프렌치 도어의 간섭 방지 설계)

  • Lee, Jin-Gyu;Yun, Jae-Deuk;Jung, Yoong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2031-2037
    • /
    • 2011
  • The French doors have the advantage that they can use inner space more efficiently due to without of partition between two rooms. However, when they are used for refrigerators, the door gaskets for sealing may cause interference of themselves during opening and closing, which causes fatal effect on sealing by worn out of the gaskets as well as increases door opening force. This research proposes a new mechanism for the French doors using the parallelogram motion of 4-bar linkage mechanism, which does not make any interference between gaskets. We manufactured the French doors of proposed mechanism to verify that they do not cause any interference during opening and closing, as well as opening force is decreased. The use of our developed mechanism is not limited to refrigerators, but can be extended to other industrial products with the French doors.