• Title/Summary/Keyword: Door to Door

Search Result 1,728, Processing Time 0.031 seconds

A Numerical Study for Performance of Automotive HVAC System (전산해석에 의한 자동차용 HVAC 시스템의 성능 연구)

  • Lee Dae-Woong;Yoo Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1084-1091
    • /
    • 2004
  • In automotive air handling system, mixing of air streams by the cooler and the heater affects the comfort of cabin room. In the present study, computer-aided analysis is done to improve the thermal comfort and for the optimal design of automotive HVAC system. The simulation software used was FLUENT, and complicate geometries were created by three dimensional CAD. Air flow volume, fir distribution rate and temperature controllability and temperature differences between upper and lower discharge air are analyzed through numerical simulation at vent, floor and defrost mode. Also, velocity vector of sirocco fan is investigated through the scroll housing. The velocity vector magnitude is larger at lower region of fan than that at any other regions. Recirculation and disturbance of air is relatively high near the cut-off edge in the scroll housing. By using the results of this study, the time for prototype production can be reduced and timely decisions can be made to determine initial design directions.

A Study on the Airtightness Performance of New Han-ok Bedrooms (신한옥 침실 공간의 기밀성능 평가 연구)

  • Lee, Ju-Yeob;Jang, Hyeon-Chung;Lee, Tai-Gang;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

Consumer Acceptance of Cosmetics Labels and Satisfaction Levelwith Cosmetics after Purchase:Viewed by the Type of Distribution Channel

  • Jeong, Hyo-Won;Hwang, Choon-Sup
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.12
    • /
    • pp.1486-1496
    • /
    • 2011
  • The present study analyzed the consumer acceptance of labels, satisfaction with cosmetics after purchase, the relationship between consumer acceptance of cosmetics labels and satisfaction with cosmetics as viewed by type of distribution channel. The study was implemented through a descriptive survey method based on a self-administered questionnaire. The sample consisted of 759 women between the ages of 21 and 49, residing in the area of Seoul, Gwangju, and Gyeonggi Province. There were significant differences in the levels of consideration of labels among consumers from each type of distribution channel. Consumers that prefer door-to-door sales consider the information about ingredients more crucial than consumers who prefer other types of distribution channels, department store consumers consider manufacturer information more important, and consumers who prefer specialty stores/chains and discount stores consider the date of manufacture less important than other types of distribution channels. Significant differences were found in consumer satisfaction with cosmetics after purchasing among consumers from each type of distribution channels. A significant relationship was found between the level of considering the product information listed on the labels and the satisfaction with the cosmetics. With respect to most of the factors, a higher level of label consideration was correlated with a higher satisfaction with cosmetics after purchase.

A Case Study on Evaluation of Educational Space in point of Universal Design - Focused on a Middle and High School - (교육공간에 대한 유니버설 디자인 관점에서의 평가 사례연구(2) - 중·고등학교 사례를 중심으로 -)

  • Oh, Chan-Ohk;Kim, Sun-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.5
    • /
    • pp.23-33
    • /
    • 2012
  • This study evaluated two educational spaces, one middle school and one high school in point of universal design. The survey method with an observation and measuring method was used. The subject were 238 students of a middle and a high school. They evaluated their schools according to 53 universal design related items which consisted of 5 principles. Findings were as follows ; 1) The width of passage between desk and desk was very narrow and there is the threshold at the door of classroom. The students evaluated them negatively, too. Also, they indicated that the size of individual locker was small and the corner of furniture was sharp. 2) The width of door and passage was narrow and the floor was not flat in restroom. The design quality such as color and finishes was not good. Also, the students evaluated all these items negatively. 3) The dining space was too big. That is, so many students takes meals in one big space. The dining tables were arranged in a long rows and the width between them was also so narrow to pass through. 4) The student of high school evaluated their educational environments more negatively than ones of middle high school. This means that the high school students were more dissatisfied with their school environment. The educational environment should be designed on the base of their students' needs.

  • PDF

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.

A Study on the Deformation of Folk Village (전통민속마을의 주거변형실태에 관한 연구 - 낙안민속마을을 중심으로 -)

  • Park, Ik-Soo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.6 no.3
    • /
    • pp.63-74
    • /
    • 2004
  • This study is focusing on the Nagan Folk Village, primarily because of its historical and cultural values. The purpose of this study, accordingly, analysis the fact of the dwelling change through spot-survey and case-investigation, and is to find a way to improve for the rational preservation of the traditional dwelling analyzing on the actual condition and the reason for such changes in the Nakan Folk Village. The dwelling change is stemmed from the physical factors, and some modifications of internal composition, exterior formation, building equipment. As a result, The changes of internal composition are included in the reduction of garnering room, the enlargement of bed/service room, the establishment of mechanical room. The changes of exterior formation with structural material are included in the glass door for the internalization of 'TOEMARU', the extra glass door for the brightening of room, the cement plastering for the endurance of wall. The changes of building equipment are included in the establishment of oil-boiler, wash closet, sink for convenient life All houses should be graded on their qualitative value, managed in a cycle. And its own criterion for acceptable deformations should be established.

  • PDF

A Study on the Displacements-Thermal Stress Analysis of Smoke/Heat Interception Screen in Eire Door (방화문용 연기/열 차단막의 변위-열응력 해석에 관한 연구)

  • 이동명
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.73-78
    • /
    • 2004
  • This study investigated about smoke/heat interception screen that can protect underneath of fire door and floor when occur fire, and keep out leakage or diffusion of smoke/heat. In this study, to considered differential pressure form smoke control area and mechanical force by fluid buoyancy of smoke when occur fire and stream of heat, are analyzed to used $ANSYS^{\circledR}$ of finite element analysis code. It presented direction of optimal design of smoke/heat interception screens that can minimize loading condition from study results, and helped that construct basic engineering data of smoke/heat interception systems as that utilize its shape design of smoke/heat interception screens.

A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types (피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로)

  • Seo, Dong-Gil;Kim, Mi-Seon;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.156-165
    • /
    • 2020
  • In this paper, the application of evacuation delay time (Cognition time + initiation time) and examine the degree of opening of fire doors in households for evaluating evacuation safety and suggest a realistic alternative. In order to proceed with this study, first of all, the preliminary investigation on evacuation safety evacuation of residential-type buildings (Apartment, urban living houses, etc.) among the performance-oriented design targets of Gwangju Metropolitan City, which was implemented until June 2018. Then, for the two representative types that are commonly used among the previously surveyed buildings, evacuation delay time is applied to W1, W2, and respectively simulating the opening of the doors is applied to th full open, 1/4 open, the leakage gap and evacuation safety evaluation was performed. As a result of evaluating evacuation safety was found that it is difficult to secure evacuation safety regardless of evacuation delay time W1 and W2 when the fire door is fully open and 1/4 open, Only when the leakage gap is applied evacuation safety was ensured even if evacuation delay time W2 was applied. Therefore, when a residential building is subject to performance-oriented design, evaluating the application of W2 rather than W1 is considered for evacuation delay time to reflect concern about privacy infringement due to CCTV installation, etc. In order to secure the Smoke blocking performance of the fire door and to improve the performance-oriented design, I would like to propose to consider the method of applying a leak gap to the degree of opening of the fire door. Through this, it is expected that the performance-oriented design will be a step further by performing evacuation safety evaluation with more realistic data.

Which types of the strategies diffused to the public through company's announcement do contribute to the long-term performance? (공시된 경영전략의 유형별 장기실적 기여도 분석)

  • Kang, Won
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.4 no.4
    • /
    • pp.45-70
    • /
    • 2009
  • This article investigates which types of the strategies announced by the listed firms contribute to enhancing the long-term performance of the companies. Since 2002, Korean Exchange adopted the "faire disclosure policy" which mandates that all publicly traded companies must disclose material information to all investors at the same time. Thanks to the policy, Korean investors can, now, easily access the board's decision on management strategies on the same day the decision is made. If the companies trustfully carry out their announced strategies, we can decide which types of strategies actually enhance or deteriorate the long-term performance, simply by comparing the announced strategies and the firm's performance. The sample companies are confined to 60 firms that became listed in the KOSDAQ market through back-door listing from 2003 to 2005. Using only the newly listed companies, we can avoid the interference on the long-term performance of the strategies pursued before the event date. This often holds true, for many companies radically modify their strategies after the listing. Furthermore, the back-door listing companies serve our purpose better than IPO companies do, because the former tend to have a variety of announcement within a given period of time beginning the listing date. Using these sample companies, this article analyzes the effect on one year buy-and-hold returns and abnormal buy-and-hold returns after the listing of the various types of strategies announced during the same period of time. The results show that those evidences of restructuring such as 'reduction of capital' and 'resignation of incumbent board members', actually contribute to the increase in adjusted long-term stock returns. Those strategies which can be view as evidence of new investment such as 'increase in tangible assets', 'acquisition of other companies', do also helps the stockholders better off. On the contrary, 'increase in bank loans', 'changes of CEO' and 'merger' deteriorate the equity value. The last findings let us to presume that the back-door listing companies appear to use the bank loans for value-reducing activities; the change in CEO is not a sign of restructuring, but rather a sign of failure of the restructuring; another merger carried out after back-door listing itself is also value-reducing activity. This article's findings on reduction of capital, merger and bank loans oppose the results of the former empirical studies which analyze only the short-term effect on stock price. Therefore, more long-term performance studies on public disclosures are in order.

  • PDF

Study on Precise Positioning using Hybrid Track Circuit system in Metro (하이브리드 궤도회로를 이용한 지하철 정위치정차에 대한 연구)

  • Jung, Ho-Hung;Ko, Yang-Og;Li, Chang-Long;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.471-477
    • /
    • 2013
  • We have studied on the possibility of precise positioning using hybrid Track Circuit system. Hybrid Track Circuit uses RFID which replaces UHF. Hybrid Track Circuit is a part of next generation railroad signal system which is available to communicate with a railway on board system based on a realtime operating system. If applicate on a current hand operating subway, phenomenon caused by driver's mistake such as passing a stop without stopping or mismatch error between PSD and train door should be prevented.