• 제목/요약/키워드: Dong-Office

검색결과 878건 처리시간 0.026초

공공건축물의 신재생에너지 적용과 에너지 사용량 분석 (Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings)

  • 이용호;서상현;김형진;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

청주읍성(淸州邑城) 관아공해고 - 규모(規模) 및 위치(位置) 추정(推定)을 중심(中心)으로 - (A Study on the Government Office Building of Chongju Castle in the Late Yi-dynasty)

  • 김동식;김태영
    • 건축역사연구
    • /
    • 제8권1호
    • /
    • pp.41-52
    • /
    • 1999
  • This study aims to infer the plan and location of the government office building in Chongju Castle in the Late Yi-dynasty. The conclusion is as follows: 1. The Chongju Castle Map(淸州邑城圖, late in the 18th century, hereinafter referred to CCM) provides the detail arrangement and location of Government Office Building in Chongju Castle. And the road structure and plan of the CCM is almost same with the present time. 2. As compared with CCM and a Chongju-land Registration Map(淸州面地籍原圖, 1913, CRM) to infer the location of the traditional government office building in Chongju Castle, the building locations of Gaek-Sa(客舍) Donghun(東軒)'s region in CCM are almost accordance with today's. But those of Byungyoung(兵營) Group's region are represented by a little error. So the locations of Byungyoung(兵營) Group's region rearranged, moved down to be in accordance with the approach circulation of Main Gate(閉門樓) which is shown in CRM. 3. The records, on the plan of the traditional government office building in Chongju Castle, have proved that the plan of Gaek-Sa was a width of 11 bay and a depth of 2 bay. A width of 3 bay drawn in CCM, the present plan of Donghun is a width of 7 bay and a depth of 4 bay. The main building and especially the double-storied Main Gate($4{\times}3$) of Byungyoung Group are exactly in keeping with the present road structure.

  • PDF

밀양·창원지역의 PM10 중 음이온 성분 및 금속성분의 화학적 특성에 관한 연구 (A Study on the Chemical characteristics of Anion Components and Metallic Elements of PM10 in Miryang and Changwon)

  • 서정민;전보경;최금찬
    • 한국환경과학회지
    • /
    • 제13권12호
    • /
    • pp.1049-1058
    • /
    • 2004
  • PM10 concentration of total 48 samples collected from 4 sites (the root of Miryang University, Sangnam township Office in Miryang. the root of Changwon elementary school, and Junam reservoir in Changwon) turned out to range from 42.29 to 69.49{\mu}g/m^{3}$, and the average concentration was the root of Changwon elementary school $(69.49{\mu}g/m^{3})$>the root of Miryang university $(58.59{\mu}g/m^{3})$>Junam reservoir $(43.56{\mu}g/m^{3})$>Sangnam township Office $(42.29{\mu}g/m^{3}).> In particular, Junam reservoir, the Clean Area, had a slightly higher value than Sangnam township Office. It was thought although the site was plane and windy without pollutants around. it had a higher concentration value influenced by external factors including bigger population and a northeasterly wind due to a newly-established industrial complex nearby. As for water-soluble ions among PM10 particle collected in Miryang and Changwon area, SO42- accounted for $50{/%}$ and NO3-, was $35{\%}$, and the concentration order was S042->N03->Cl->F-. As for the average concentration of metallic components among PM10 particle collected in Miryang and Changwon area. the root of Changwon elementary school had the AI concentration, Fe concentration and Zn concentration 4 times, 3 times and 1.5 times that of Junam reservoir, respectively. The root of Miryang University had the AI concentration 2 times that of Sangnam township Office, and had Fe concentration and Zn concentration $1.2\~1.5$ times those of Sangnam township Office. When it comes to the relation between metallic elements and meteorological factors in Changwon area, the highest coefficient of correlation was between temperature and humidity with 0.92, and temperature and wind speed turned out in the reverse correlation. The coefficient of correlation between Al and Cr was as high as 0.78. Among metallic elements, the coefficient of correlation between Cu and Pb, Cd, Al were 0.84, 0.85, 0.79, respectively. It is thought that the high coefficient of correlation between Cu and Pb is ascribed to busy traffic and wind in the urban areas, Sammun-dong and Gagok-dong in Miryang. Meanwhile, the coefficients of correlation between Fe and Cu, Al, Zn, Cd, Pb were in the reverse correlation. These coefficients of correlation are attributed to the difference in pollutant sources, rather than difference in pollutant and non-pollutant.

사무소건물(事務所建物)의 전기설비용양(電氣設備容量) 산정(算定)에 관한 연구(硏究) (A Study on the Estimation of Electric Equipment Capacity in Office Buildings)

  • 김세동;최도혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.666-668
    • /
    • 1992
  • This paper shows a reasonable design standard of electric equipment capacity for office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, etc for 121 buildings. The saving of electric equiment investment, the decrease of power loss, the improvement of facilities utilization and the decreasse of electric power rates can be contributed by the application of the design standard.

  • PDF

역전층이 강릉시 주변 해륙풍 순환에 미치는 영향 연구 (The Effect of Inversion Layer on the Land and Sea Breeze Circulations near the Gangneung)

  • 남궁지연;유재훈;김남원;최만규;함동주;김훈상;장유정;최은경
    • 대기
    • /
    • 제15권4호
    • /
    • pp.229-239
    • /
    • 2005
  • The effect of inversion layer on the land and sea breeze near the Gangneung city was investigated. The land and sea breeze occurrence days were selected, and the height and the intensity of inversion layer were calculated with the upper air observational data of the Sokcho Station. The relationships between the temperature variation near the Gangneung and the inflow time, inland penetration and the inflow depth of the land and sea breeze were also analyzed. And the Gangwon Short-range prediction system was verified with the comparison of surface stream line by the Gangwon short-range prediction system with the AWS wind vector data. It was revealed that the inversion layer tended to block the sea breeze, shorten the inland penetration distance and lower the inflow depth, causing the temperature rise. The comparison and analysis of surface steam line by the Gangwon short-range prediction system and the AWS wind vector showed that the system quite well simulated the sea breeze, thus the system could be well utilized in the prediction of land and sea breeze.

가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구 (An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling)

  • 김동희;유기형;조동우;서정석;한성필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

AtoN AIS를 활용한 해양기상신호표지시스템 구축 (Oceanographic and Meterological Monitoring System with Aids to Navigation AIS)

  • 권혁동;이병곤;김영진
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2010년도 춘계학술대회
    • /
    • pp.555-556
    • /
    • 2010
  • 연안 수역에서의 해상교통 환경변화에 부응하고 나아가 대형 해양사고 방지와 인명사고 예방을 위해 필요한 해양기상신호표지 시스템 구축을 위하여 해양기상 관측 및 항로표지 정보제공 시스템을 도입, 통항선박에게 안전항해에 필요한 정보를 제공함으로서 해양교통 안전을 확보하고자 한다. 인천 연안의 팔미도를 포함한 15개 항로표지시설에 기상(온습도, 풍향/풍속, 기압) 및 해양(유향/유속, 수온, 파고/파향) 관측시스템을 설치하고 항로표지용 AIS (AtoN AIS) 통신시스템을 이용하여 육상 정보수집 처리서버 및 항행 선박에게 해양기상관측자료를 실시간 전송하는 시스템을 구축하였다.

  • PDF

건축규모에 따른 관리인력의 효율적 배치에 관한 기초연구 -오피스 건물을 중심으로- (A Preliminary Studty on the Efficient Management Manpower Staffing According to the Building Size -Focused on Office Buildings-)

  • 이원석;김신은;김선국;이동훈;원일우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.191-194
    • /
    • 2010
  • Construction companies are now trying a variety of cost-cutting strategies in the midst of recent slump of construction market. Notably, contract workers and local hires are accounting for increasing portion of management manpower as a part of their cost-reduction drive. However, construction site manpower researches to date have focused primarily on productivity analysis of site laborers, with little attention to the productivity of site management resources. This study aims to analyze the staffing status of office building construction site management manpower in reference to project size. Conclusions herein will provide basic inputs for subsequent attempts to build a model to enable efficient staffing of construction site management manpower.

  • PDF