• 제목/요약/키워드: Domestic hot water

검색결과 114건 처리시간 0.029초

국내의 안정적 전력 수급 확보 방안

  • 유종철;박명규
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2000년도 추계학술발표논문집
    • /
    • pp.87-90
    • /
    • 2000
  • Recently Korea has been achieved highly effective economic growth but it has triggered the high demands of Energy and it makes running out of energy. In addition to the recent oil shock has driven the republic of Korea in hot water. The main reason is that the most electricity production system is based on the heating generation. Accordingly, for the demands of domestic electricity, the generation of electricity(water power, heating power and atomic energy) should be constructed as a pending problem. Especially, the Korea which has very distinctive four seasons might have many problems to establish the generating systems. This study Provides the gate to be out of the energy Problem as a result of the construction of our proper generating systems.

  • PDF

PVT 모듈 성능 평가를 위한 기초 연구 (The Fundamental Researches to Evaluate PVT Module Performance)

  • 김필규
    • 한국태양에너지학회 논문집
    • /
    • 제38권4호
    • /
    • pp.1-9
    • /
    • 2018
  • 본 연구는 신규로 구축 된 장비의 정확성과 PVT 제품의 KS 기준의 방향성을 살펴보았다. 먼저 신규로 구축된 Indoor solar thermal simulator의 경우, 인공광의 빔 균일도와 분광 특성을 기존의 규격 조건을 충족되도록 설계했으며, 실제 시험을 통해 B 등급임을 확인하였다. Indoor solar thermal simulator 장비의 정확도는 상용 태양광 모듈 및 기존 상용 장비로 측정 후, 최대 전력값을 비교했으며 오차 값은 약 0.4%로 정확도가 높음을 확인하였다. PVT 제품의 효율은 기존의 태양광 모듈 KS 기준과 태양열 집열기 KS 기준을 준용하여 측정하면 될 것으로 보이며, PVT 제품의 구조적 특징인 열매체 냉각에 의한 추가 전기 효율 방법 개발은 필요해 보이며, 본 연구에서는 태양광 모듈 케이블의 단락 유무에 따른 효율 상승 차이를 살펴보았고 추가 전기 효율 측정 방법으로 가능성을 제시하였다. 다양한 PVT 모듈의 유형에 따라 특히, PVT 모듈 전면에 유리 커버 유무에 따라 출력 감소가 발생되고 추가 공정에 의해 전기 출력 특성이 달라지는 값을 고려하여 PVT 제품의 전기 효율 측정 시험은 인증을 받은 제품을 이용하여 제작을 했어도 반드시 재시험이 필요하다고 판단되며, 시험방법이 수립되어야한다. 마지막으로 PVT 제품의 내구성 평가를 경우, 기존의 태양광 모듈 및 집열기의 내구성 시험의 모든항목을 KS 인증 시험 항목에 포함 시켜야 된다고 판단되며, 제품의 특성에 따라 시험의 재배열을 추가 연구가 필요해 보이며, 집열기 부분의 내구성을 고려하여 합부 기준을 추가적으로 고려해야 한다고 판단된다.

국내산 키위연육제 제조과정 중 부형제의 첨가가 키위분말의 품질에 미치는 영향 (The Effect of Bulking Agent on Quality of Kiwifruit Powder in the Process of Domestic Kiwifruit Tenderizer)

  • 노정해;김영붕;길복임
    • 한국식품과학회지
    • /
    • 제34권5호
    • /
    • pp.805-810
    • /
    • 2002
  • 본 연구는 키위연육제 개발의 기초자료로 제공하기 위해 단백분해효과가 있는 국내산 키위를 건조가공한 후 건조방법과 부형제 첨가에 따른 이화학적 특성을 비교분석하였고 12주 동안 저장하면서 품질변화를 관찰하였다. 건조 이전 전처리를 달리한 경우 paste 형태로 전처리를 한 경우가 dice 전처리 처리구보다 2.0배, 일반 과육형태보다는 1.3배 높은 단백불해활성을 나타내었다. 건조과정 중 변화를 보면 열풍 건조는 9시간 동안 동결건조는 46시간 동안 키위 paste의 수분감소가 90% 이상 진행되었으며 이 시간 동안 색의 변화가 주로 관찰되었다. 건조분말은 열풍건조한 경우 동결건조 처리구에 비해 수율이 낮았으나 수분함량은 거의 차이가 나지 않았다. 열풍건조한 처리구의 경우 현저한 단백분해효소 활성의 저하를 나타내었고 동결건조한 처리구는 열풍건조보다 약 6.6배정도 많은 단백분해효과를 나타내었다. 키위 고유의 색은 동결건조를 하는 경우 유지되었다. 건조전 부형제를 첨가한 것에 의한 효과를 보면 동결건조에서는 부형제에 의한 차이가 적으나 열풍건조에서는 dextrin 5%첨가한 키위분말이 높은 건조분말수율과 낮은 수분함량을 보여주었다. 단백분해활성은 부형제를 넣고 열풍건조한 처리구의 경우 부형제 무처리구보다 약 $3.2{\sim}3.6$배 더 높은 효소역가를 보여주었고 이 역가는 동결건조 결과물에 비해 60% 정도 잔존하는 것으로 나타났다. 부형제에 의한 색의 차이는 관찰되지 않았다. 12주 저장하는 동안 모든 처리구에서 건조 전 부형제를 첨가한 분말연육체의 수분함량은 저장 내내 안정된 경향의 수분보유력을 보여주었다. 단백분해효소 활성은 열풍건조의 경우 건조전 부형제를 첨가한 처리구는 저장 4주까지 단백분해효소의 활성 감소를 보이다가 안정화되었다. 따라서 키위 고유의 색을 유지하고 가공 후 분말내 단백분해효소 잔존량을 높이기 위해서는 동결건조가 효율적이나 부형제를 적절히 처리한 후 열풍건조를 하는 방법도 경제성 측면에서 좋은 대안이 될 수 있음을 보여주었다.

루프형태의 밀폐형 Thermosyphon의 작동특성과 시스템 모델링에 관한 연구 (A Study on the Operating Characteristics and System Modelling of Closed Loop Type Thermosyphon)

  • 강명철;강용혁;이동규
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.39-47
    • /
    • 2002
  • The thermosyphon SDHWS and the loop type thermosyphon systems are widely used for domestic hot water system. The loop type thermosyphon is a circulation device for transferring the heat produced at the evaporator to the condenser area in the loop. In this study, the operating characteristics of various working fluids being used have been identified. The working fluids employed in the study were ethanol. water, and a binary mixture of ethanol and water. The volume of working fluid used in this study were 30%, 40%, 50%, 60% and 70% of evaporator volume. It is observed that, in the thermosyphon with low volume of working fluid, such as 30% or 40%, the fluid was dried out. The flow pattern and mechanism of the heat transfer were identified through this study. Flow patterns of the binary mixture working fluid were also investigated, and the patterns were recorded in the camera. The system parameters were calculated using the thermal performance data. Modelling of the system was carried out using PSTAR method and TRNSYS program.

수입산 혼합 유칼립투스 칩과 국내산 백합 나무 (Liriodendron tulipifera) 칩의 소다-안트라퀴논 (soda-anthraquinone) 펄핑 특성 비교 (Comparison of the soda-anthraquinone pulping properties between imported Eucalyptus mixture chips and domestic yellow poplar (Liriodendron tulipifera)chips)

  • 성용주;이준우;김세빈;신수정
    • 펄프종이기술
    • /
    • 제42권3호
    • /
    • pp.22-27
    • /
    • 2010
  • Pulping properties of the imported mixed eucalyptus chips and the domestic yellow poplar chips were investigated for comparing two chips as the raw materials for the hardwood chemical pulp. Soda-AQ (anthraquinone) pulping was applied for this study. The pulp from yellow poplar showed higher pulp yield than pulp from mixed eucalyptus, which comes from the lower hot-water soluble extractives and the higher polysaccharides in yellow poplar chips than those of the mixed eucalyptus chips. The yellow poplar pulp had higher average fiber length and fiber width than those of the mixed eucalyptus pulp, which led to the better respond to beating and the higher tear strength than those of the pulp from the mixed eucalyptus chips.

방열관의 배치와 관내 유속이 온수난방 온실의 온도분포에 미치는 영향 (Effect of Pipes Layout and Flow Velocity on Temperature Distribution in Greenhouses with Hot Water Heating System)

  • 신현호;김영식;남상운
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.335-341
    • /
    • 2019
  • 본 연구는 난방온실의 온도분포 균일화를 위한 기초자료 제공을 목적으로 온수난방 방식의 토마토 재배 온실에서 난방실험을 통하여 난방배관의 표면온도와 실내기온 사이의 상관관계를 분석하고, 난방배관의 열전달특성 분석과 난방배관 배치의 개선을 통하여 난방배관 표면온도의 편차를 줄이고 균일도를 향상시키기 위한 방안을 도출하였다. 서로 다른 두 온실의 온도분포를 분석하여 최대편차와 균일도를 검토한 결과, 온수의 유량이 많고 난방배관의 길이가 짧게 배치된 온실의 온도편차가 작고, 균일도는 높은 것으로 나타났다. 또한 순환팬을 가동한 경우에 온도편차는 작아지고 균일도가 개선되는 것을 확인할 수 있었다. 난방배관의 표면온도와 실내기온 사이의 상관관계를 분석한 결과, 두 온실 모두에서 유의적인(p<0.01) 정적 상관관계가 있는 것으로 나타났다. 온수난방 온실에서 실내기온의 분포는 난방배관 표면온도의 분포에 영향을 받는다는 것을 확인할 수 있었고, 온도편차가 최소화 되도록 난방배관을 배치함으로써 실내기온 분포의 균일도를 개선할 수 있는 것으로 판단되었다. 난방배관의 열전달 특성을 분석한 결과 배관의 길이가 길어지면 온도편차는 커지고, 관내의 유속이 빨라지면 온도편차는 작아지는 것으로 나타났다. 따라서 지선배관의 길이가 짧아지도록 난방배관을 배치하고, 관내의 유속을 제어함으로써 온실의 온도분포와 환경의 균일성을 개선할 수 있을 것으로 판단되었다. 국내 온실에서 가장 많이 사용하고 있는 튜브레일(40A) 방식의 온수난방시스템에서 하나의 지선배관에서의 온도편차를 $3^{\circ}C$ 이내로 조절하기 위해서는 관내의 유속이 0.2, 0.4, 0.6, 0.8, $1.0m{\cdot}s^{-1}$일 때 난방배관의 길이는 각각 40, 80, 120, 160, 200m 이내로 제한해야 하는 것으로 분석되었다.

국산 홍합과 뉴질랜드 초록입 홍합 열수 추출물의 알코올분해효소 활성에 미치는 영향 및 DPPH 라디칼 소거능과 Angiotensin Converting Enzyme 저해 활성 (Effects of Hot Water Extracts of Domestic Blue Mussel and New Zealand Green Lipped Mussel on Alcohol Metabolizing Enzymatic, DPPH Radical Scavenging, and Angiotensin Converting Enzyme Inhibitory Activities)

  • 김시경;옥둘이;박은주;이승철
    • 한국식품영양과학회지
    • /
    • 제43권9호
    • /
    • pp.1363-1368
    • /
    • 2014
  • 우리나라 남해안 연안에서 주로 양식되는 진주담치(국산 홍합)와 세계적으로 기능성이 잘 알려진 뉴질랜드 초록입 홍합의 열수 추출물을 제조하여 생리활성을 비교하였다. 모든 홍합 추출물들은 알코올대사와 관련한 alcohol dehydrogenase(ADH)와 acetaldehyde dehydrogenase(ALDH)의 활성을 상승시켰으며, 특히 ADH의 활성을 크게 향상시켰다. 국산 홍합의 육질 추출물은 초록입 홍합의 육질 추출물에 비하여 ADH 상승 효과는 비슷하였으며, ALDH 상승 효과는 약간 낮았다. DPPH 라디칼 소거능으로 조사한 항산화능은 국산 홍합의 육질 추출물이 초록입 홍합의 육질 추출물 보다 높았다. 항고혈압과 관련한 ACE 저해능의 경우에는 국산 홍합 육질 추출물이 초록입 홍합의 육질 추출물에 비해 10 mg/mL 농도에서는 낮았으나 20 mg/mL 이상의 농도에서는 유의차(P<0.05)를 보이지 않았다. 이상의 결과는 국내에서 양식되고 있는 홍합도 세계적으로 초록입 홍합에 못지않은 생리활성을 가지고 있음을 시사한다.

안경렌즈 코팅의 평가 방법에 관한 비교 연구 (A Comparative Study on Test Methods for Ophthalmic Lens Coatings)

  • 유동식;문병연;하진욱
    • 한국안광학회지
    • /
    • 제11권1호
    • /
    • pp.7-15
    • /
    • 2006
  • 안경렌즈의 코팅에 대한 평가방법을 검토하였고 렌즈 제조사에서 제공되는 몇 종류의 렌즈에 대해 코팅 평가하였다. 플라스틱 안경렌즈의 생산은 양적으로 크게 증가 추세에 있다. 하지만 플라스틱 안경렌즈의 경도가 약한 관계로 렌즈표면의 내구성 향상은 절대적으로 필요하다. 이를 개선하기 위해 코팅방법을 이용하고 있으며, 안경 렌즈 코팅의 평가는 생산된 렌즈를 무작위로 선택하여 물리적, 화학적으로 평가하고 있지만 투과율 항목을 제외한 부착력, 내마모성, 경도, 내약품성 및 내온수성에 대한 국내 또는 국제적 기준이 없다. 안경렌즈 평가기준이 아닌 다른 기준에 의해 일부 적용하고 있는 기준은 제품간의 비교가 혼란될 수 있는 관계로 이에 대한 평가 기준이 필요하다.

  • PDF

지역난방 급탕공급 부하균등화를 위한 잠열축열조의 현장 적용 (Field Application of a Latent Heat Storage Tank for Load Shaving of Domestic Hot Water Supply in District Heating)

  • 박성용;유호선
    • 플랜트 저널
    • /
    • 제17권2호
    • /
    • pp.42-47
    • /
    • 2021
  • 지역난방의 운영적 측면에서 특정시간의 피크부하 완화를 통한 효율적인 열생산과 공급 및 지역난방 공급 중단 시 급탕 공급은 난방 대비 대체가 어려워 사용자 측면의 불편함과 공급자 측면의 애로사항을 해결할 수 있는 적용 기술이 요구되고 있다. 본 연구에서는 이러한 문제점을 해결할 수 있는 기술 중 열저장 능력과 급탕공급에 적합한 78℃급 수화물계 잠열축열조를 제작하여 지역난방 사용자 아파트 급탕공급설비에 현장 적용하였다. 본 시스템의 적용 결과 기존 공급방식 대비 급탕온도의 변화가 거의 없이 일정하게 사용자에게 공급됨을 확인하였으며, 피크 열부하는 평균 35% 감소와 비상열원으로서의 활용 가능성을 확인하였다. 또한 부하균등화에 따른 피크부하 감소로 기존 열 공급시설에서 10%의 열공급 여유와 신규 열공급시설 건설비용 및 열사용자의 공사비부담금이 각 5%와 10%가 감소됨을 확인하였다.

국내 태양복사 분포 및 변화특성 (Distribution and Variation Characteristic of Solar Radiation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.200.1-200.1
    • /
    • 2010
  • Solar energy is one of the most promising energy resources in the future. For the application and dissemination of solar energy technologies in various fields, reliable data sets of solar irradiation are needed for engineers, researchers, businessmen, and policy makers. Global horizontal solar radiation is needed for the use of flat plate collector, solar domestic hot water system, photovoltaic devices and passive systems like green house. In many countries, solar radiation data accumulated for more then 40 or 50 years and typical weather data are published with average of more then 30 years. In Korea, those global total radiations are measured for about 30 years. With the connections of computer network, measured data could be transmitted to the central control system at key station through Ethernet lines. The data acquisition systems are connected to be automatically controlled by the monitoring network. Global horizontal solar radiation data 16 locations were measured and averaged from 1982 to 2008.

  • PDF