• Title/Summary/Keyword: Domestic hot water

Search Result 114, Processing Time 0.025 seconds

Experimental Investigation on the Optimal Design of Water Tank for Domestic Hot Water Supply using PEMFC Co-generation System (가정용 고분자 전해질 연료전지 열병합 발전시스템의 급탕 적용을 위한 온수 저장조의 최적 설계에 관한 실험적 연구)

  • Hwang, Yu-Jin;Ahn, Young-Chull;Cheong, Seong-Ir;Jin, Keun-Ho;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.394-399
    • /
    • 2008
  • There are many attempts to use a fuel cell system as a residential power generation system. The purpose of this study is to investigate the optimal design of a water tank for a hot water system when the fuel cell co-generation system is combined with a domestic hot water supply system. The demands of hot water supply per month per home are investigated in Busan for a year. It showed somewhat large differences between the actual demand and the designed demand of hot water, but the actual capacity of hourly averaged hot water demands is analyzed as $60{\ell}/h$ in this study based on the actual demand. The experiments are performed in the various inlet and outlet locations of nozzles, and the hot water consumption rates. The experimental results are showed that the optimal capacity of the water tank is $200{\ell}$ when the thermal efficiency, the storing capacity of hot water and the space for installation are considered.

Thermal Performance of Solar Hot Water and Space Heating in a Combi - Storage Tank (태양열 급탕 난방 복합 축열조 열성능)

  • Kwak, Hee-Youl;Joo, Hong-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.266-269
    • /
    • 2009
  • The Purpose of this study was thermal performance of solar hot water and space heating thermal storage tank. The combi storage tank was designed Tank in Tank type. The tank volume for space heating was 700 $\ell $ and tank volume for hot water was 150 $\ell $. Tank in Tank type storage tank was to replace heat exchange to hot water tank. The result showed that the Heating value was 67.25MJ and domestic hot water value was 51.93MJ. Supply to the hot water volume was 521 $\ell $ more than about 3 times as that of the hot water tank volume.

  • PDF

Domestic Status of Solar Thermal Collectors and Hot Water Heaters (태양열 집열기 및 온수기에 대한 국내 현황)

  • Kim, Seok-Jong
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.84-88
    • /
    • 1991
  • In this technical status report, domestic solar makers and dealers for thermal collectors and hot water heaters are surveyed. The characteristics and specifications of their items are also classified and discussed. Collectors and hot water heaters are the key part of solar thermal systems which have been developed under the national policy for the development and utilization of new and renewable energy resources. This report provides the current domestic status of solar collectors which may be a good reference for the solar industry and related organizations.

  • PDF

Thin Layer Chromatography on the Influence of Hot Water Extractives of Domestic and Foreign Wood Species on the Cement Setting (국산(國産) 및 외국산(外國産) 수종(樹種)의 열수추출물(熱水抽出物)이 시멘트경화(硬化)에 미치는 영향(影響)에 대한 박층(薄層)크로마토그래피적(的) 분석(分析))

  • Suh, Jin-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.67-72
    • /
    • 1993
  • Hot water extractives of sawdust/particle from domestic and foreign wood species, which were composed of pitch pine, Korean pine, larch, Italy poplar, acacia and oak as Korean wood species, Malaysian oil palm and German spruce were quantitatively analyzed with thin layer chromatography. Sugar components of saccharose, galactose, glucose, fructose and arabinose were contained in these wood species. It was assumed that arabinose and glucose are major inhibitory components against cement hardening in larch and oil palm, respectively, since both species contain a large amount of each sugar. In contrast, fructose might not influence so badly on a cement hardening, when considering that fructose was contained much in Italy poplar with a good cement hardening character. Galactose was a minor component.

  • PDF

Development of monitoring system for demonstration test of solar energy system (태양에너지 시스템의 실증시험을 위한 모니터링 시스템 개발)

  • Yang, Dong-Jo;Kim, Jae-Yeol;Oh, Yool-Kwon;Kim, Jin-Heung;Chung, Nak-Kyu;Cho, Guem-Bae
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.723-726
    • /
    • 2005
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구)

  • Lee, Dong-Won;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

Energy Performance Analysis of Solar Hot Water Heating System used in an Office Building Using the Dynamic Simulation (시뮬레이션을 이용한 사무소건물 적용 태양열 급탕시스템의 에너지성능 분석)

  • Ko, Myeong-Jin;Choi, Doo-Sung;Kim, Yong-Shik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.281-285
    • /
    • 2009
  • This paper is to simulate a solar hot water heating system used in a medium-scale office building using the dynamic simulation. This study is focused chiefly on the annual variation of energy performance, the solar fraction with respect to the difference of hot water load temperature. For this purpose the simple model of a solar hot water heating system has been considered with TRNSYS program and the simulations were performed with the weather data in Seoul, Korea. The share ratio of solar hot water system of the summer season appeared higher than the winter season because that the decrease of the domestic hot water load was far despite the relative decrease of the solar radiation. As the temperature was lower from $60^{\circ}C$ to $50^{\circ}C$, the solar fraction increases 8.1 percent due to 20-percent decrease of annual hot water load.

  • PDF

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

A Study on the Optimum Design for a Solar Domestic Hot Water System (小規模 太陽熱 給湯시스템 의 最適設計 에 관한 硏究)

  • 서정일;이영수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.6
    • /
    • pp.517-525
    • /
    • 1984
  • This paper presents a typical solar domestic hot water system and estimates their performances with variance of collector size, storage volume, collector tilt and other factors. The analysis is performed by th computer simulation for which conceptual system against 8760 hourly solar intensities and ambient temperature for a model year stored in the computer has been running. System performance is analyzed on hourly, monthly and yearly basis respectively and at the same time, the economics of various systems are evaluated. And also, this paper shows how an optimized design can be selected for any locality for which solar data and collector performance are provided. The results of this study are as follows. (1)Storage volume of 45 liter per square meter of solar collector lead to the best design. (2)Tilting the collectors to the same angle of the latitude is generally the best (3)Optimal size of collector is approximately 6.68-8.35m$^{2}$ when the latitude is 37.6 .deg. N and storage volume is 300 liter. (4)The performances of a solar domestic hot water system does not depend on the hourly usage but the daily usage.

A Study on the Energy Conservation Effect of Each Energy Consumption Component In Indoor Swimming Pools (실내수영장의 에너지 소비요소별 에너지 절약효과에 관한 연구)

  • 김영돈;권규동;여명석;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1092-1101
    • /
    • 2002
  • The objective of this study is to develop energy saving strategies for indoor swimming pools and to estimate the effect of each energy saving strategy. For this purpose, field measurements regarding pool water heating energy, domestic hot water heating energy are conducted and a base energy consumption model is implemented using the DOE-2.1E program. The results of the study reveal that 25% of the total pool water heating energy may be saved by using night time pool covers, 27% of the total domestic hot water heating energy may be saved by using a waste water heat recovery system (effic. 60%), and of the total ventilation energy may be saved using an exhaust air heat recovery system (effic. 60%).