• Title/Summary/Keyword: Domestic Wastewater

Search Result 322, Processing Time 0.028 seconds

Pipe Stiffness Prediction of Buried Flexible Pipes (지중매설 연성관의 관강성 추정)

  • Park, Joon-Seok;Kim, Sun-Hee;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • In this paper, we present the result of an investigation pertaining to the pipe stiffness of buried flexible pipes. Pipe stiffness (PS) formula for the parallel plate loading condition is derived based on the elasticity theory. Vertical and horizontal displacements are also derived. Vertical deflection is always larger than the horizontal deflection because some of energy due to overburden load is stored in the pipe but the difference is negligibly small. In the study, mechanical properties of the flexible pipes produced in the domestic manufacturer are tested and the results are reported in this paper. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is less than 14% although there are significant variations in the mechanical properties of the pipe material. Therefore, it was found that the finite element analysis can be used to predict the pipe stiffness instead of conducting parallel plate loading test.

Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity- (CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 -)

  • Park, No-Suk;Kim, Seong-Su;Choi, Jong-Woong;Sung, Youl-Boong;Kang, Moon-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.

Chemical Coagulation Conditions and Efficiency of Sewage with Al(III) and Fe(III) Coagulants (하수의 화학적 응집조건 및 응집제별 응집효율 분석)

  • Park, June-Gue;Tian, Dong-Jie;Park, Noh-Back;Jun, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.463-474
    • /
    • 2010
  • In this study, chemical coagulation conditions for treating combined sewer overflow(CSO) occurred during rainy season were evaluated by jar tests with aluminum sulfate[$Al_2(SO_4)_3{\cdot}17H_2O$] and ferric chloride[$FeCl_3{\cdot}6H_2O$]. The raw domestic sewage sampled from the primary sedimentation tank at a local sewage treatment plant was filtered through $150{\mu}m$ sieve before using. Point of zero charge(PZC) for various dose of aluminum sulfate occurred at pH 5.8-6.5, while for ferric chloride occurred at pH 5.3-6.0 in term of streaming current(SC) values. Charge neutralization ability of aluminum sulfate was bigger than that of ferric chloride. Optimum pH and dose of aluminum sulfate and ferric chloride were 6.2, 0.438mM and 5.8, 0.925mM, respectively. Removal efficiencies of TCOD, turbidity, SS and TP were 75, 97, 95, 96% with aluminum sulfate and 74, 96, 98, 99% with ferric chloride at their optimum coagulation conditions. More efficient removal of SS, TP and small particles was possible with ferric chloride at optimum coagulation conditions. Both SC values and COD removal started to increase where soluble phosphorus was completely removed.

The improvement of sewerage fee imposition system for efficient rainwater management (효율적 빗물관리를 위한 하수도 요금체계 개편 방안)

  • Park, Kyoo-Hong;Kang, Byong-Jun;Park, Joo-Yang;Park, Wan-Kyu;Kim, Sung-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.517-527
    • /
    • 2014
  • As sewer flooding frequents due to localized and concentrated stormwater and increased non-permeable surface area after urbanization, building cities with sound water recycle and accordingly efficient management of rainwater is demanded. To do this, the existing sewage (including rainwater) fee imposition system should be philosophically evaluated. This study presents problematic issues of the existing domestic sewage fee imposition system considering the principle of sharing costs on the service of sewage and rainwater collection and treatment. Four methods to improve the existing sewage fee imposition system are suggested: 1) imposing stormwater fee according to Polluter Pays Principle, 2) clarification of the share of public sector, 3) reducing or exempting the sewerage fee for inhabitants reducing urban runoff by constructing their own rainwater management facilities, 4) imposing charge for discharging rainwater to sewers due to new development action. Short, mid, or long term planning for rainwater management is recommended considering the situation of each municipality.

Effects of Ultrasonic Pretreatment on Sludge Biodegradability (초음파 전처리에 의한 슬러지 생분해성 영향 평가)

  • Kim, Ju-Hyun;Lee, Kang-Hoon;Nguyen, Hai;Yeom, Ick-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.611-616
    • /
    • 2011
  • The impacts of ultrasonic pretreatment on the biodegradability of domestic sewage sludge were evaluated through a series of anaerobic digestion experiments in batch system. The gas and methane production from the sludge samples pretreated by an ultrasonic tool with different durations were measured with time. Although the biogas production increased with the extent of sludge solubilization and the period of ultrasonic pretreatment, the enhancement of sludge biodegradability was much more sensitive to the pretreatment for the relatively short periods. Most of the enhanced biodegradability by the pretreatment was appeared in the early stage of anaerobic digestion, less than 6 days. The maximum biogas production per day was observed between 4 to 6 days when the sludge was pretreated less than 10 minutes while it was obtained in the beginning for the sludge pretreated longer periods. The results suggest that the repeated alternation of low strength ultrasonic pretreatment and anaerobic digestion may be more effective than the combination of one time pretreatment for a relatively long period and following anaerobic digestion.

A Study on the Simultaneous Removal of Organics and Nutrients in Upflow Packed Bed Column Reactor (상향류식 충전탑형 반응기에 의한 유기물 및 영양염류 동시 제거에 관한 연구)

    • KSBB Journal
    • /
    • v.18 no.3
    • /
    • pp.234-238
    • /
    • 2003
  • Biofilm process is preferred to activated sludge process in small domestic wastewater treatment plant because of its simplicity in operation and maintenance. Column reactor filled with waste ceramics and with waste plastics was used to remove pollutants in restaurant wastewater. COD removal at 18 hours of hydraulic retention time (HRT) gave 93.7%, COD removal during the experimental period, where maximum COD removal was observed. Under same condition, average removal of total nitrogen and total phosphorus were 82.3% and 25.9%, respectively Organic and nitrogen were efficiently removed with the HRT of 18 hours or more.

Categorization and definition of microplastics in the water environment (수환경에서의 마이크로플라스틱 분류 및 정의)

  • Kwon, Bumgun;Lee, Sanghoon;Rah, Hynjoo;Paek, Jin;Kim, Keugtae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.429-436
    • /
    • 2019
  • Since the discovery of the first artificial synthetic plastic, bakelite, polymer materials have been recognized as one of the most innovative fields of research. The plastic debris that is being piled up on the earth (called abandoned plastic litters) is now being observed everywhere on Earth, becoming an increasingly serious environmental threat. The term 'microplastics', created in 2004, now refers to plastic particles that are smaller than 5 mm, including all nano-sized plastic particles. However, there is no legal regulation, and there is still a lack of comprehensive definitions that practically include microplastic size standards. In this study, we will refer to "microplastics" as the English name, and look at how to identify these microplastics and propose new definitions that focus on their size. This study is expected to contribute to the domestic consensus on scientific definitions of microplastics.

The Removal of Organics in an Oxidation Ditch (산화구에서의 유기물 처리에 관한 연구)

  • 김건흥
    • Water for future
    • /
    • v.13 no.3
    • /
    • pp.71-76
    • /
    • 1980
  • The oxidation ditch is an efficient, low cost form of treatment of domestic and many industrial waste. It has gained rapid acceptance because of its simplicity, low cost operation, ease of operation, simple mintenance and flexibiltiy. The objective of this investigation was to measure the removal of organics in an existing dithc that does not have return sludge and which is not preceded by primary sedimentation. To accomplish this objective, samples of the wastewater influent and effluent were collected from the wastewater treatment plant of Mansfield, Texas during practical training. These samples were collected over an extended period of time to obtain samples at various treatment temperatures. Two analytical tests, COD and suspended solids, were used to monitor the operation of the plant. The results show that high removal efficiencies were obtained at high temperatures, with the efficiency decreasing as the temperature decreased to approximatedly 16$^{\circ}C$, at which point the efficienty tmeperature relationship appeared to stabilize.

  • PDF

Determination of Optimum Operational Parameters on Early Warning Device for Early Detection of Taste and Odor in Drinking Water Supplies (상수원수 내 이취미 조기감지를 위한 조기경보장치의 최적운전인자 도출)

  • Kim, Young-Il;Bae, Byung-Uk;Ju, Dae-Sung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.849-855
    • /
    • 2006
  • Taste and odor (T&O) problems in drinking water supplies caused by eutrophication have become increasingly important because aesthetic qualities are the primary measures by which consumers estimate the quality of their drinking water. In order to overcome T&O problem, it is necessary to early detection method for T&O compounds before these compounds enter to water treatment plant. In this background, a early waming device for T&O compounds was developed and its performance tested under different operating condition. According to the experimental results on the adsorption efficiency of T&O compounds, when the raw water flowrate was 5 mL/min, the optimum stripping time and air flowrate were 5 hrs and 0.5 L/min, respectively. Comparison of activated carbon showed that foreign activated carbon was better than domestic activated carbon in terms of adsorption efficiency.

Degradation characteristics and intermediate study of tetracycline in aqueous system by liquid ferrate(VI) (Liquid ferrate(VI)에 의한 다양한 수중 환경에서의 tetracycline 분해특성 및 중간생성물 연구)

  • Park, Kyeong-Deok;Kang, Dong-Hwan;So, Yoon-Hwan;Cho, Joung-Hyung;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.61-73
    • /
    • 2020
  • Tetracycline is one of the most commonly used antibiotics in domestic and foreign livestock industries to suppress the growth of pathogens. Tetracycline has been reported as a non-biodegradable compound. Therefore it has been not completely removed in the sewage treatment process. In this study, tetracycline was degraded using liquid ferrate (VI). Based on these experiments, the optimal water condition (pH and water temperature) were selected, appropriate liquid ferrate (VI) dosage was calculated, and finally the degradation pathway was estimated with the intermediate products detected by LC/MS/MS. All degradation experiments were completed within 30 seconds and the optimal condition was obtained in basic condition (pH 10) at room temperature (20℃). And the appropriate molar ratio between tetracycline and liquid ferrate (VI) was 12.5:1. Finally, 12 intermediate products were detected with LC/MS/MS and the degradation pathways and the degradation pathways and proposed the degradation pathways.