• Title/Summary/Keyword: Dome Structure

Search Result 196, Processing Time 0.023 seconds

Modeling of the triangle optimum shape in the surface of an Aluminum dome structure (알루미늄 돔 구조물에서 표면의 삼각형 최적 형상 모델링)

  • 이성철;조종두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.647-650
    • /
    • 1997
  • A complete dome structure is based on a basic dome modeling, and the basic dome modeling affects safety of the dome structure. In other to save the manufacture expenses, an optimum shape modeling of a dome structure is necessary work of before manufacture of the dome. In this study, modeling of the triangle optimum shape in the surface of an aluminum dome is more focused to optimize shape of the dome and save manufacture expenses. After being made the systematic procedure of the basic modeling, the programming work of the procedure is performed. The program is made by C language, and the trust of the program is proved by comparison between output data of the program and basic modeling in PATRAN.

  • PDF

Determination of Member Force Ratios for Self-equilibrium State of Multi-Layered Cable Dome Type Structures (다층 케이블 돔형 구조물의 자기평형을 위한 부재력 비율 결정)

  • Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.2
    • /
    • pp.75-82
    • /
    • 2013
  • For each cable component in a cable dome structure, pre-tension is needed for stability of whole the structure. The summation of these pre-tension at each joint should be zero to achieve the self equilibrium structure. The first step in cable dome structure analysis is to find the ratio of pre-tension in each member which can produce a stable and structure on self-equilibrium. In this paper, a new method based on the basic principle of closed force polygon for equilibrium system is proposed for the determination of self-equilibrium mode of cable dome structure. A single layer cable dome and two multi layer type domes have been analyzed. The ratios of cable members are determined by the presented method, and check the validation of the results by numerical calculation.

RESEARCH ON LOAD-BEARING PROPERTY AND DESIGN OF CABLE DOMES

  • Shen Cao;Zi Zhu
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.596-605
    • /
    • 2005
  • The cable dome, proposed by Geiger after developing Fuller's idea of tensegrity and improved by Levy, is a new type of large span space structures. In this paper, formulations of the initial forces distribution in members of two main systems of cable dome, which are Geiger dome and Levy dome, are presented. By analyzing the static performance of Levy dome and the variation of internal forces in members of the structure, four groups of design parameters in cable dome structure are represented in terms of: (1) the numbers of rings and the spaces between the rings; (2) the slopes of ridge cables; (3) the lengths of struts; (4) the initial force in one member of the structure.

  • PDF

Seismic Response Control of Dome Structure Subjected to Multi-Support Earthquake Excitation (다중지점 지진하중을 받는 돔 구조물의 지진응답 제어)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.4
    • /
    • pp.89-96
    • /
    • 2014
  • Spatial structures as like dome structure have the different dynamic characteristics from general rahmen structures. Therefore, it is necessary to accurately analyze dynamic characteristics and effectively control of seismic response of spatial structure subjected to multi-supported excitation. In this study, star dome structure that is subjected to multi-supported excitation was used as an example spatial structure. The response of the star dome structure under multiple support excitation are analyzed by means of the pseudo excitation method. Pseudo excitation method shows that the structural response is divided into two parts, ground displacement and structural dynamic response due to ground motion excitation. And the application of passive tuned mass damper(TMD) to seismic response control of star dome structures has been investigated. From this numerical analysis, it is shown that the seismic response of spatial structure under multiple support seismic excitation are different from those of spatial structure under unique excitation. And it is reasonable to install TMD to the dominant points of each mode. And it is found that the passive TMD could effectively reduce the seismic responses of dome structure subjected to multi-supported excitation.

Dome Structure using High-Density EPS Review of Safety (고밀도 EPS를 이용한 돔 구조 안전성에 대한 고찰)

  • Jang, Suk-Jun;Lee, Dong-Un
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.119-120
    • /
    • 2011
  • Dome structure to form a space-efficient, applied a lot of beautiful buildings with structural systems, as well as a large space structure in the form of new residential lots have been applied. And domestic demand for housing in the dome with increasing dome house using various materials, are becoming commonplace. But now the Dome House is mainly used in construction steel, wood, stone, FRP construction and building materials per unit area and the high cost, long construction time, energy efficiency, has some disadvantages such as degradation. And structural strength of the structure is weak, the natural ingredients used come from natural damage is so big. In addition, demolition of buildings in trouble when handling the environmental problems has emerged. Recently expanded polystyrene to improve these problems by using the various approaches and research is being attempted and there.

  • PDF

Continuous size optimization of large-scale dome structures with dynamic constraints

  • Dede, Tayfun;Grzywinski, Maksym;Selejdak, Jacek
    • Structural Engineering and Mechanics
    • /
    • v.73 no.4
    • /
    • pp.397-405
    • /
    • 2020
  • In this study size optimization of large-scale dome structures with dynamic constraints is presented. In the optimal design of these structure, the Jaya algorithm is used to find minimal size of design variables. The design variables are the cross-sectional areas of the steel truss bar elements. To take into account the constraints which are the first five natural frequencies of the structures, the finite element analysis is coded in Matlab programs using eigen values of the stiffness matrix of the dome structures. The Jaya algorithm and the finite elements codes are combined by the help of the Matlab - GUI (Graphical User Interface) programming to carry out the optimization process for the dome structures. To show the efficiency and the advances of the Jaya algorithm, 1180 bar dome structure and the 1410 bar dome structure were tested by taking into the frequency constraints. The optimal results obtained by the proposed algorithm are compared with those given in the literature to demonstrate the performance of the Jaya algorithm. At the end of the study, it is concluded that the proposed algorithm can be effectively used in the optimal design of large-scale dome structures.

A Study on the Stabilizing Process and Structural Characteristics of Cable-Dome Structure (케이블돔 구조물의 안정화 이행과정 및 구조적 거동특성에 관한 연구)

  • 한상을;이경수;이주선;황보석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.260-267
    • /
    • 1999
  • In this paper, We propose the initial shape finding and dynamic analysis of cable dome structure are presented. Cable dome that is consist of three component such as cable, strut and fabric membrane have complex structural characteristics. Main structural system of cable dome is cable-strut tensegric system, and fabric membrane element Is conceived as cladding roof material. One of the important problem of cable dome is shape finding of those subjected to cable and membrane forces, which stabilize the structures. And the other is structural response from external load effect such as snow and wind When cable dome are subjected to dynamic load such as wind load each structural component has many important problem because of their special structural characteristics. One problem is that geometrical nonlinearity should be considered in the dynamic analysis because large deformation is occurred from their flexible characteristic. The other problem is that wrinkling occurs occasionally because cable and membrane elements can not transmit compressive forces. So this paper describe the physical structural response of cable dome structure.

  • PDF

Appraisal of deployable dome structures under wind loading

  • Parke, G.A.R.;Toy, N.;Savory, E.;Abedi, K.;Chenaghlou, R.
    • Wind and Structures
    • /
    • v.1 no.4
    • /
    • pp.317-336
    • /
    • 1998
  • In this paper the appraisal of a folding dome structure under the influence of wind loading is discussed. The foldable structure considered is constructed from an assembly of interconnected elements, together with a flexible membrane, all of which are initially store in a compact form and on deployment expand, like an umbrella, into a dome structure. Loading on the dome was obtained from a wind tunnel analysis of the pressure distribution over the roof of a 1:10 scale model of the structure. The critical loading obtained from the wind tunnel investigation was used, together with individual member and material tests, to form a series of numerical non-linear finite element models which were, in turn, used to investigate the forces within the structure. The numerical analysis was used to determine the critical wind loading that the structure can sustain, as well as providing a method by which to investigate the failure modes of the structure. In order to enhance the load carrying capacity of the dome it was found that both the strength and stiffness of the structural nodes needed to be enhanced and in addition, changes were necessary to substantially increase the stiffness of the individual member and caps.

Seismic Response Analysis of Dome-Shaped Large Spatial Structures According to TMD Installation (TMD 설치에 따른 돔 형상 대공간 구조물의 지진응답분석)

  • Ku, Seung-Yeon;Yoo, Sang-Ho;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.4
    • /
    • pp.27-34
    • /
    • 2023
  • In this study, the seismic response characteristics of the three analysis model with or without TMD were investigated to find out the effective dome shape. The three analysis models are rib type, lattice type and geodesic type dome structure composed of space frame. The maximum vertical and horizontal displacements were evaluated at 1/4 point of the span by applying the resonance harmonic load and historical earthquake loads (El Centro, Kobe, Northridge earthquakes). The study of the effective TMD installation position for the dome structure shows that seismic response control was effective when eight TMDs were installed in all types of analysis model. The investigation of the efficiency of TMD according to dome shape presents that lattice dome and geodesic dome show excellent control performance, while rib dome shows different control performance depending on the historical seismic loads. Therefore, lattice and geodesic types are desirable for seismic response reduction using TMD compared to rib type.

Application of TMD for Seismic Response Control of Dome Structure (돔 구조물의 지진응답 제어를 위한 TMD의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.1
    • /
    • pp.99-108
    • /
    • 2012
  • Vibration control devices are classified into passive, semi-active and active device. TMD(Tuned Mass Damper) is one of the passive control device that is mainly used to reduce vibration level of building structure and bridge structure. In this study, the application of passive tuned mass damper(TMD) to seismic response control of dome structures has been investigated. Because star dome structure has primary characteristics of dome structures, star dome structure was used as an example dome structure that is subjected to horizontal or vertical seismic loads. From this numerical analysis, it is shown that seismic response are influenced by vibration modes and it is reasonable to install TMD to the dominant points of each mode. And it is found that the passive TMD could effectively reduce the seismic responses of dome structure.