• Title/Summary/Keyword: District heating

Search Result 437, Processing Time 0.025 seconds

An Analysis of Consumption Patterns in Residential Sector of District Heating (지역난방의 주택용 열소비행태 분석)

  • Kim, Jin Hyung
    • Environmental and Resource Economics Review
    • /
    • v.10 no.2
    • /
    • pp.217-234
    • /
    • 2001
  • The use of district heating is expanding very rapidly in Korea. High population densities and the relatively cold winters make district heating an economically attractive option. About 8 percent of Korean houses are already using district heating and the government is seeking to aggressively expand this number. It has set a target of 15 percent of the residential heat market to be met by district heating in the year 2001. The main purpose of this paper is to analyze the consumption behavior of households using district heating. By pooling time-series and cross-sectional data for 12 apartment complexes in Seoul area, a single demand function is estimated and used to forecast the amounts of heat demanded by the individual households. The results shows that the level of consumption varies among households, depending on the non-economic factors such as the installation of individual metering equipment and the volume of apartment building. When individual metering equipment is installed, the level of annual heat consumption per household declines, on average, about 22.1 Mcal per square meters, which is equivalent to 834 won per square meter in terms of heating expenditures. In case that the apartment building was built in more than 6 stories, annual consumption level reduces additionally about 17.3 Mcal per square meters and, thus, save the expenditures by 649 Won per square meters, compared to the opposite case.

  • PDF

A Study on Establishment of the IoT-Based Remote Management System for District Heating Facilities (지역난방설비를 위한 IoT 기반 원격 관리 시스템 구축에 대한 연구)

  • Kim, Jun-hyeok;Lee, Sang-hak;Kim, Byung-min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.3
    • /
    • pp.698-701
    • /
    • 2017
  • The district heating system supports currently 1.3 million of houses in South Korea, and it is composed of two main parts: provision and distribution. For the provision part, Korea District Heating Corporation supervises the system with proper devices and experts, whereas for the distribution parts, there is no main supervision system and it depends highly on experts although it is very difficult to find the proper experts. In this paper, we consider IoT based remote management system for district heating distribution to properly supervise heating distribution by experts and/or programs remotely.

A Study on the Design Capacity of 2-stage Hot Water Heat Exchanger in Apartment Housings with District Heating System (지역난방 공동주택에서 급탕 2단 열교환기 용량의 적정성 평가에 관한 연구)

  • Sa, Ki-Yong;Chung, Kwang-Seop;Kim, Young-Il;Na, Chai-Moon;Kim, Sung-Min;Kim, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1037-1042
    • /
    • 2009
  • In connection with a recent research project dealing with heating system in apartment buildings by district heating, it was realised that in general very little information on the actual performance of heating and hot water systems in apartment buildings has been documented. In order to improve of district heating systems, a prediction of the heat demand first needs to be determined before a production plan. this is hot water heat system developed in this paper. this is also analyzed relation heat load with preheat load in hot water heating exchanger system.

  • PDF

Development of Three-Way Proportional Control Valve and Performance Study (3방 비례제어 조절밸브 개발 및 성능 연구)

  • Lee, Jonghwa;Jung, Taeksu;Cho, Chongdu;Kim, Jooyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

KDHA NEWS

  • Korea District Heating Association
    • Intergrated Energy Industry
    • /
    • s.2
    • /
    • pp.76-77
    • /
    • 2005
  • PDF

KDHA NEWS

  • Korea District Heating Association
    • Intergrated Energy Industry
    • /
    • s.3
    • /
    • pp.85-87
    • /
    • 2006
  • PDF

KDHA Photo

  • Korea District Heating Association
    • Intergrated Energy Industry
    • /
    • s.4
    • /
    • pp.2-5
    • /
    • 2006
  • PDF

NEWS

  • Korea District Heating Association
    • Intergrated Energy Industry
    • /
    • s.4
    • /
    • pp.62-63
    • /
    • 2006
  • PDF