• 제목/요약/키워드: District cooling

검색결과 192건 처리시간 0.04초

지역냉방을 위한 아이스슬러리의 연속제조 및 배관내 빙충전율 조절 (Continuous Ice Slurry Production and Control of Ice Packing Factor in a Pipe for the District Cooling)

  • 권재성;이윤표;이상훈;유호선;윤석만
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.825-832
    • /
    • 2008
  • The ice slurry maker which can produce the ice slurry well for the ice particle in-flowing condition was revised. We removed the stagnant region at the top of the ice slurry maker, and IPF 40% could be realized. The IPF controller with 6 mm diameter holes at the bottom was designed. But the IPF controller with only 6 mm diameter holes could not control IPF in a pipe. This is because the ice particles at ice slurry flow exist homogeneously not only at the upper part but also at the bottom part. We changed the hole size of IPF controller surface using fine meshes and then, IPF in a pipe was increased by 70% when the hole size was $80{\mu}m$ and less.

동적계획법을 이용한 고온수배관의 최적보온설계에 관한 연구 (A study on the optimal design for heat insulation of hot water piping systems using a dynamic programming)

  • 유희한;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.39-52
    • /
    • 1987
  • Recently, the design problem of heat insulation have been reappraised in the aspect of energy saving due to the rising trend of energy cost. For example, that design problem is increasingly requsted in the fields of accommodation air conditioning systems, hot water supply systems, cargo handling systems, district heating or cooling systems. The rational design of heat insulation of piping systems can not only improve the overall efficiency of energy transfer but also give energy saving. In this paper, the heat insulation problem of district heating systems is therefore modeled as the multi-stage decision processes, suitable for dynamic programming technique. And take the object function as the sum of heat insulation material cost involved construction cost and heat loss cost, and propose the design method to minimize the object function for overall piping systems by dynamic programing. Effectiveness of design method presented here is proved by a computer simulation.

  • PDF

Location Analysis for Emergency Medical Service Vehicle in Sub District Area

  • Nanthasamroeng, Natthapong
    • Industrial Engineering and Management Systems
    • /
    • 제11권4호
    • /
    • pp.339-345
    • /
    • 2012
  • This research aims to formulate a mathematical model and develop an algorithm for solving a location problem in emergency medical service vehicle parking. To find an optimal parking location which has the least risk score or risk priority number calculated from severity, occurrence, detection, and distance from parking location for emergency patients, data were collected from Pratoom sub-district Disaster Prevention and Mitigation Center from October 2010 to April 2011. The criteria of risk evaluation were modified from Automotive Industry Action Group's criteria. An adaptive simulated annealing algorithm with multiple cooling schedules called multi-agent simulated quenching (MASQ) is proposed for solving the problem in two schemes of algorithms including dual agent and triple agent quenching. The result showed that the solution obtained from both scheme of MASQ was better than the traditional solution. The best locations obtained from MASQ-dual agent quenching scheme was nodes #5 and #133. The risk score was reduced 61% from 6,022 to 2,371 points.

지역난방에 연계된 하이브리드 제습냉방시스템의 경제성 분석 (Thermoeconomic Analysis of Hybrid Desiccant Cooling System Driven by District Heating)

  • 안준;김재율;강병하
    • 대한기계학회논문집B
    • /
    • 제38권9호
    • /
    • pp.721-729
    • /
    • 2014
  • 지역난방에 연계한 하이브리드 제습냉방 시스템은 하절기 에너지 이용효율을 높일 수 있다. 실증실험을 통해 우리나라에 성공적으로 운전될 수 있다는 것을 확인한 하이브리드 제습냉방 시스템의 보급활성화를 위하여 경제성 분석을 실시하였다. 기존의 전기 에어컨과 냉방을 하면서 생기는 비용을 비교하는 것과 전기 에어컨을 제습냉방으로 대체하였을 때 발생하는 국가 편익을 계산하는 두 가지 관점에서 수행하였다. 분석결과 제습냉방은 30% 이상의 운전비용 절감효과가 있으며, 1기당 연간 0.079 TOE의 1차 에너지, 0.835 $TCO_2$ 절감효과가 있는 것으로 분석되었다. 2020년까지 68만세대에 제습냉방이 보급된다고 예상하면 463 MW의 전력대체 효과가 발생하는 것으로 분석되었다. 이러한 운전비용절감효과, 1차 에너지 절감 및 온실가스 배출 감소효과를 가지고 있는 제습냉방 시스템은 전기 에어컨에 비하여 초기 투자비용이 높기에 보급활성화를 위하여 적절한 정부의 보조금이 필요하다. 본 논문에서는 국가적 편익을 고려한 적절한 보조금을 산정하여 제습냉방 시스템의 보급방안을 제시하고자 한다.

지하대수층을 이용한 축열시스템의 설계(II) : 열해석 (Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis)

  • 이관수;이태희;송영길
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

분산전원 보급확대를 위한 지역냉난방 집단에너지사업 운용방안 (The Improvement of District Heating/Cooling Business for increasing Distributed Generating Resources)

  • 조기선;이창호;이원구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.305-307
    • /
    • 2007
  • 본 논문은 지역냉난방 집단에너지사업의 열원다원화를 위한 미활용폐열의 연계공급방안의 수립을 통한 지역냉난방 집단에너지사업의 개선방안을 제시하였다. 산업단지에서 발생되는 폐열에 대한 효율적인 회수 메커니즘과 연계공급 및 활용방안에 대한 전반적인 검토를 통한 미래 산형 에너지공급시스템의 근간이 될 집단에너지사업의 장기적 발전을 도모코자 하였다.

  • PDF

지역난방 공동주택의 에너지원별 원단위 사례분석 (Case Study on the Energy Consumption Unit of District Apartments)

  • 이왕제;강은철;이의준;오병칠;신우철
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구 (A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems)

  • 강희정;이현수;장명훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2018
  • A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.