• Title/Summary/Keyword: District

Search Result 4,272, Processing Time 0.034 seconds

Characteristics of Ion Index by Type of Land Use in Small City - Focused on Chungju (중소도시 토지이용유형별 이온지수 특성 - 충주시를 대상으로 -)

  • Kim, Jeong-Ho;Lee, Sang-Hoon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.489-497
    • /
    • 2018
  • In this study, the ion index characteristics of small and medium urban land use types were investigated in the city of Chungju. The average temperature for each land use type was in the order: general commercial district ($29.59^{\circ}C$) > general residential district ($28.34^{\circ}C$) > productive green district ($28.31^{\circ}C$). The average relative humidity was in the order: productive green district (70.12%) > general residential district (69.93%) > general commercial district (66.48%). The average wind speed was in the order: productive green district (0.95 m/s) > general commercial district (0.87 m/s) > general residential district (0.54 m/s). Positive and negative ions were investigated to determine the ion index by land use type. The average amount of positive ion generated was in the order: general commercial district ($737ea/cm^3$) > general residential district ($492ea/cm^3$) > productive green district ($445ea/cm^3$). The average negative ion production decreased in the order: productive green district ($930ea/cm^3$) > general residential district ($754ea/cm^3$) > general commercial district ($744ea/cm^3$). The ion index calculated from measured data can be arranged in the order: productive green district (2.09) > general residential district (1.53) > general commercial district (1.01). These results confirm the state of positive and negative ion generation in each land use type. Further, the differences in the ion index by land use type were confirmed. However, a limitation of this study is that simple summer measurements were conducted, and seasonal characteristics were not considered. Therefore, any future investigation and research should consider seasonal variation characteristics.

Evaluation of Soil in Planting Ground at Seashore Reclaimed Land in Incheon (인천지역 해안매립지 식재기반 평가 연구)

  • Kim, Won-Tae;Yoon, Yong-Han;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1447-1455
    • /
    • 2011
  • The purpose of this study was to analyze physicochmical characteristics of oil within planting base of Incheon coastal reclamation cities where 10 years have passed since reclamation, and to provide basic data to promote growth and development of plants by conducting evaluation based on the planting degree standard. Study targets were Cheongra, Sondo, and Yeongjong districts within Incheon Free Economic Zone, the coastal reclamation city. The analysis results of average soil characteristics of 3 districts. Soil acidity(pH) was shown in orders of Cheongra district(8.85) > Songdo district(8.70) > Yeongjong district(7.97) and electric conductivity(EC) was shown in orders of Cheongra district(4.80 dS/m) > Songdo district(1.30dS/m) > and Yeongjong district(0.07 dS/m). Organic matter content(OMC) was shown in orders of Cheongra district(5.72%) > Songdo district(2.60%) > Yeongjong district(0.59%) and available phosphate was shown in orders of Cheongra district(70.70 mg/kg) > Songdo district(23.07 mg/kg) > Yeongjong district(2.49 mg/kg). $K^+$ was shown in orders of Songdo district(0.84 cmol/kg) > Cheongra district(0.74 cmol/kg) > Yeongjong district(0.22 cmol/kg), $Ca^{++}$ was shown in orders of Cheongra district(22.08 cmol/kg) > Songdo district(9.87 cmol/kg) > Yeongjong district(4.04 cmol/kg), and $Mg^{++}$ was shown in orders of Cheongra district(1.98 cmol/kg) > Songdo district(1.22 cmol/kg) > Yeongjong district(1.12 cmol/kg). Planting base level of coastal reclaimed land can be applied with above intermediate level, soil acidity and available phosphate were all more than intermediate in 3 districts, and electric conductivity was low level in Cheongra district and more than intermediate level in Songdo and Yeongjong districts. Organic matters content was more than intermediate level in Cheongra district and low level in Songdo and Yeongjong district. $K^+$ among exchangeable ions was intermediate level in Cheongra and Songdo districut and low in Yeongjong district. $Ca^{++}$ and $Mg^{++}$ both were more than imtermidiate levels in 3 districts.

A study on the air pollutant emission trends in Gwangju (광주시 대기오염물질 배출량 변화추이에 관한 연구)

  • Seo, Gwang-Yeob;Shin, Dae-Yewn
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.1-26
    • /
    • 2009
  • We conclude the following with air pollution data measured from city measurement net administered and managed in Gwangju for the last 7 years from January in 2001 to December in 2007. In addition, some major statistics governed by Gwangju city and data administered by Gwangju as national official statistics obtained by estimating the amount of national air pollutant emission from National Institute of Environmental Research were used. The results are as follows ; 1. The distribution by main managements of air emission factory is the following ; Gwangju City Hall(67.8%) > Gwangsan District Office(13.6%) > Buk District Office(9.8%) > Seo District Office(5.5%) > Nam District Office(3.0%) > Dong District Office(0.3%) and the distribution by districts of air emission factory ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%). That by types(Year 2004~2007 average) is also following ; Type 5(45.2%) > Type 4(40.7%) > Type 3(8.6%) > Type 2(3.2%) > Type 1(2.2%) and the most of them are small size of factory, Type 4 and 5. 2. The distribution by districts of the number of car registrations is the following ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%) and the distribution by use of car fuel in 2001 ; Gasoline(56.3%) > Diesel(30.3%) > LPG(13.4%) > etc.(0.2%). In 2007, there was no ranking change ; Gasoline(47.8%) > Diesel(35.6%) > LPG(16.2%) >etc.(0.4%). The number of gasoline cars increased slightly, but that of diesel and LPG cars increased remarkably. 3. The distribution by items of the amount of air pollutant emission in Gwangju is the following; CO(36.7%) > NOx(32.7%) > VOC(26.7%) > SOx(2.3%) > PM-10(1.5%). The amount of CO and NOx, which are generally generated from cars, is very large percentage among them. 4. The distribution by mean of air pollutant emission(SOx, NOx, CO, VOC, PM-10) of each county for 5 years(2001~2005) is the following ; Buk District(31.0%) > Gwangsan District(28.2%) > Seo District(20.4%) > Nam District(12.5%) > Dong District(7.9%). The amount of air pollutant emission in Buk District, which has the most population, car registrations, and air pollutant emission businesses, was the highest. On the other hand, that of air pollutant emission in Dong District, which has the least population, car registrations, and air pollutant emission businesses, was the least. 5. The average rates of SOx for 5 years(2001~2005) in Gwangju is the following ; Non industrial combustion(59.5%) > Combustion in manufacturing industry(20.4%) > Road transportation(11.4%) > Non-road transportation(3.8%) > Waste disposal(3.7%) > Production process(1.1%). And the distribution of average amount of SOx emission of each county is shown as Gwangsan District(33.3%) > Buk District(28.0%) > Seo District(19.3%) > Nam District(10.2%) > Dong District(9.1%). 6. The distribution of the amount of NOx emission in Gwangju is shown as Road transportation(59.1%) > Non-road transportation(18.9%) > Non industrial combustion(13.3%) > Combustion in manufacturing industry(6.9%) > Waste disposal(1.6%) > Production process(0.1%). And the distribution of the amount of NOx emission from each county is the following ; Buk District(30.7%) > Gwangsan District(28.8%) > Seo District(20.5%) > Nam District(12.2%) > Dong District(7.8%). 7. The distribution of the amount of carbon monoxide emission in Gwangju is shown as Road transportation(82.0%) > Non industrial combustion(10.6%) > Non-road transportation(5.4%) > Combustion in manufacturing industry(1.7%) > Waste disposal(0.3%). And the distribution of the amount of carbon monoxide emission from each county is the following ; Buk District(33.0%) > Seo District(22.3%) > Gwangsan District(21.3%) > Nam District(14.3%) > Dong District(9.1%). 8. The distribution of the amount of Volatile Organic Compound emission in Gwangju is shown as Solvent utilization(69.5%) > Road transportation(19.8%) > Energy storage & transport(4.4%) > Non-road transportation(2.8%) > Waste disposal(2.4%) > Non industrial combustion(0.5%) > Production process(0.4%) > Combustion in manufacturing industry(0.3%). And the distribution of the amount of Volatile Organic Compound emission from each county is the following ; Gwangsan District(36.8%) > Buk District(28.7%) > Seo District(17.8%) > Nam District(10.4%) > Dong District(6.3%). 9. The distribution of the amount of minute dust emission in Gwangju is shown as Road transportation(76.7%) > Non-road transportation(16.3%) > Non industrial combustion(6.1%) > Combustion in manufacturing industry(0.7%) > Waste disposal(0.2%) > Production process(0.1%). And the distribution of the amount of minute dust emission from each county is the following ; Buk District(32.8%) > Gwangsan District(26.0%) > Seo District(19.5%) > Nam District(13.2%) > Dong District(8.5%). 10. According to the major source of emission of each items, that of oxides of sulfur is Non industrial combustion, heating of residence, business and agriculture and stockbreeding. And that of NOx, carbon monoxide, minute dust is Road transportation, emission of cars and two-wheeled vehicles. Also, that of VOC is Solvent utilization emission facilities due to Solvent utilization. 11. The concentration of sulfurous acid gas has been 0.004ppm since 2001 and there has not been no concentration change year by year. It is considered that the use of sulfurous acid gas is now reaching to the stabilization stage. This is found by the facts that the use of fuel is steadily changing from solid or liquid fuel to low sulfur liquid fuel containing very little amount of sulfur element or gas, so that nearly no change in concentration has been shown regularly. 12. Concerning changes of the concentration of throughout time, the concentration of NO has been shown relatively higher than that of $NO_2$ between 6AM~1PM and the concentration of $NO_2$ higher during the other time. The concentration of NOx(NO, $NO_2$) has been relatively high during weekday evenings. This result shows that there is correlation between the concentration of NOx and car traffics as we can see the Road transportation which accounts for 59.1% among the amount of NOx emission. 13. 49.1~61.2% of PM-10 shows PM-2.5 concerning the relationship between PM-10 and PM-2.5 and PM-2.5 among dust accounts for 45.4%~44.5% of PM-10 during March and April which is the lowest rates. This proves that particles of yellow sand that are bigger than the size $2.5\;{\mu}m$ are sent more than those that are smaller from China. This result shows that particles smaller than $2.5\;{\mu}m$ among dust exist much during July~August and December~January and 76.7% of minute dust is proved to be road transportation in Gwangju.

A Study on Architectural Design Decision in District Unit Plan Area - with Apartment Houses at Suwan District in Gwangju - (지구단위계획 지구에서의 건축디자인 결정에 관한 연구 - 광주 수완지구 공동주택을 중심으로 -)

  • Park, Hyun-Joo;Kim, Yun-Hag;Yun, In-Jung;Park, Joo-Yeon;Cho, Yong-Joon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.273-277
    • /
    • 2008
  • Architectural design guideline of Korea prescribed that district unit plan was established for development over fixed scale since 2000 and it was based on the intention to make district view contextually. But, it was not applicable to practice and as a result of research, setting of district image was not clear when development of district unit plan was completed and elements and contents of district unit plan for embodying it were finite or theoretical. In addition, architectural design neglected contextual view of the whole district based on district unit plan and was inclined to individual view within district, and architectural deliberation was also inclined to individual view within the district rather than contextual view rather than contextual view. Therefore, district unit plan requires decision of element and range as design management for setting image and embodying it when development is completed and architectural design or deliberation must be also premised on district view.

  • PDF

Proper Arrangement of City Park though Analysis of Disposition Distance (유치거리 분석을 통한 도시공원의 적정배치에 관한 연구)

  • Ryu, Yeun-Soo;Ra, Jung-Hwa;Do, Hu-Jo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.20
    • /
    • pp.33-38
    • /
    • 2002
  • The purpose of this study is to analysis of disposition distance of city park for the plan of suitable arrangement of city park based on the date examining Daegu Metropolitan City. The results of this study are as follows. 1) The result of analysis of population density as the case of districts, it appeared highly in city center area which Seo-Gu district and Nam-Gu district besides Jung-Gu district. However, it apperared in a low Buk-Gu district, Dong-Gu district and Salseong-Gun. 2) The result of analysis of population density as the case of regions, it appeared very highly Joukjun-Dong of Dalseo-Gu district($31,554per/km^2$), Naedang-Dong of Seo-Gu district($29,922per/km^2$). However it appeared in a low Yeuga-Maen($85per/km^2$) and Gachang-Maen($94per/km^2$) of Dalseong-Gun. The regions where the population density is high have very low green space and live a lot of low income layer. 3) The result of analysis of disposition distance, in the case of children park, it appeared an intensive distribution in Dongcheon-Dong and Guam-Dong of Buk-Gu district, Whanggm-Dong and Dusan-Dong of Suseong-Gu district, Sangin-Dong and Yeongsan-Dong and Walsung-Dong of Dalseo-Gu district. however, it appeared in a low in Jung-Gu district. The case of urban park of the neighboring area, it appeared the most in Dalseo-Gu district except 2 parks in Jung-Gu district, the case of urban park of the walking area, it appeared in equality in city. 4) In conclusion, the area have high population density and lots of low income layer, is in out of disposition distance should be considered in first for city park plan.

  • PDF

A Study on the Dwelling Site Planning in the Residential Improvement District as a Sustainable Development - Focused on the Nanminchon II District in Jeonju - (지속가능한 개발로서 주건환경개선지구내 주거지계획에 관한 연구)

  • Kim, In-Sun;Jihn, Jung
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.73-80
    • /
    • 2007
  • The purpose of this study is to suggest that dwelling site planning of residential improvement district is to make in the point of sustainable improvement. The methods of this study are as follow, first, introduce the concept of sustainable improvement and research possibility of adaption of the concept. second, make a survey of the Nanminchon II District in Jeonju as a sample of residential improvement district and make a comparative study of the before and after the development. third, research adaptable elements of sustainable residence concept to Nanminchon II District to dwelling site planning. Progress and result of residential improvement district affects dweller to character of place and habitation and will gain summits of architecture.

Toxicological Study for Blood Cyanide and Carboxyhemoglobin Levels in the Fire- related Fatalities

  • Baeck, Seung-Kyung;Kim, Dong-Woo;Kim, Sun-Chun;Park, Woo-Yong;Jin, Kwang-Ho;Chung, Young-Ho;Park, Yun-Shin;Seo, Joong-Seok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.170.2-170.2
    • /
    • 2003
  • The most common cause of death in fires is the inhalation of noxious gases rather than thermal injury. Carbon monoxide is well-known toxic component in fire atmospheres. However, the importance of hydrogen cyanide(HCN) as a toxic agent in the fire related fatalities(FRF) is under discussion. HCN is known to be produced in fires involving by the pyrolysis of polyacrylonitril (PAN) and other nitrogen-containing polymer. (omitted)

  • PDF