• 제목/요약/키워드: Distribution system power flow

검색결과 339건 처리시간 0.028초

선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구 (A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

Blockchain for Securing Smart Grids

  • Aldabbagh, Ghadah;Bamasag, Omaimah;Almasari, Lola;Alsaidalani, Rabab;Redwan, Afnan;Alsaggaf, Amaal
    • International Journal of Computer Science & Network Security
    • /
    • 제21권4호
    • /
    • pp.255-263
    • /
    • 2021
  • Smart grid is a fully-automated, bi-directional, power transmission network based on the physical grid system, which combines sensor measurement, computer, information communication, and automatic control technology. Blockchain technology, with its security features, can be integrated with Smart Grids to provide secure and efficient power management and transmission. This paper dicusses the deployment of Blockchain technology in Smart Grid. It presents application areas and protocols in which blockchain can be applied to in securing smart grid. One application of each area is explored in detail, such as efficient peer-to-peer transaction, lower platform costs, faster processes, greater flexibility in power generation to transmission, distribution and power consumption in different energy storage systems, current barriers obstructing the implementation of blockchain applications with some level of maturity in financial services but concepts only in energy and other sectors. Wide range of energy applications suggesting a suitable blockchain architecture in smart grid operations, a sample block structure and the potential blockchain technicalities employed in it. Also, added with efficient data aggregation schemes based on the blockchain technology to overcome the challenges related to privacy and security in the smart grid. Later on, consensus algorithms and protocols are discussed. Monitoring of the usage and statistics of energy distribution systems that can also be used to remotely control energy flow to a particular area. Further, the discussion on the blockchain-based frameworks that helps in the diagnosis and maintenance of smart grid equipment. We have also discussed several commercial implementations of blockchain in the smart grid. Finally, various challenges have been discussed for integrating these technologies. Overall, it can be said at the present point in time that blockchain technology certainly shows a lot of potentials from a customer perspective too and should be further developed by market participants. The approaches seen thus far may have a disruptive effect in the future and might require additional regulatory intervention in an already tightly regulated energy market. If blockchains are to deliver benefits for consumers (whether as consumers or prosumers of energy), a strong focus on consumer issues will be needed.

원형 다공배플이 있는 덕트에서의 열전달과 마찰계수에 관한 수치해석 (Numerical analysis of heat transfer and friction factors in a duct having circular perforated baffles)

  • 오세경;안수환;;배성택
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.44-50
    • /
    • 2012
  • The present numerical study was performed to determine how the two perforated baffles( Inclined angle=$5^{\circ}$; perforation diameter=2cm) placed at a rectangular duct affect heat transfer and associated friction factors. The parametric effects of perforated baffles(3, 6 and 12 holes) and flow Reynolds number ranging from 28,900 to 61,000 on the heated target surface are explored. As for the investigation of heat transfer behaviours on the local Nusselt number with two baffles placed at $x/D_h=0.8$ and $x/D_h=0.8$ of the edge baffles, it is evident that the average Nusselt number increases with increasing number of holes, but the friction factor decreases with an increase in the hole number placed at baffles. The numerical results by commercial code CFX 10.0 are confirmed with the experimental data.

건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구 (A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation)

  • 이용호;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.

열원온도와 작동유체에 따른 초월임계 유기랭킨사이클의 열역학적 성능 특성 (Thermodynamic Performance Characteristics of Transcritical Organic Rankine Cycle Depending on Source Temperature and Working Fluid)

  • 김경훈
    • 대한기계학회논문집B
    • /
    • 제41권11호
    • /
    • pp.699-707
    • /
    • 2017
  • 본 연구에서는 아홉 종류의 작동유체를 고려하여 저온 열원으로 구동되는 아임계 및 초월임계 유기 랭킨 사이클의 열역학적 성능 특성을 비교 해석한다. 터빈입구압력, 열원온도 및 작동유체가 열교환기 내 온도분포와 핀치포인트, 작동유체의 유량, 시스템 출력 및 열효율 등 시스템의 성능에 미치는 영향을 분석한다. 해석 결과는 작동유체의 압력이 아임계 영역에서 초임계 영역으로 높아지면 열교환기에서 열원과 작동유체 사이의 온도 불균일 정도가 감소하면서 시스템 출력이나 열효율 등은 증가하나 시스템의 단위출력당 터빈 크기는 작아짐을 보여준다.

화력발전용 가스재열기의 응력 해석 (Stress Analysis of Gas-Gas Heater in Thermal Power Plant)

  • 황석환;최재승;이후광
    • 한국정밀공학회지
    • /
    • 제19권1호
    • /
    • pp.204-211
    • /
    • 2002
  • Today\`s industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization(FGD) system is installed in thermal power plant and gas-gas heater(GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas-gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design. And finite element analysis(FEA) for rotor part in GGH is performed with original model and two weight-reduced models with different diaphragm thickness, respectively. Stress concentrations at rotor diaphragm happen due to the dead weight, pressure difference between treated and untreated gas, and thermal distribution in the rotor. As the thickness of diaphragm is decreased, the stress level is increased. The direction of treated gas and untreated gas flow may affect the stress level.

상반전 조류발전 터빈의 형상설계 및 성능예측에 관한 연구 (A Study on the Performance Estimation and Shape Design of a Counter-Rotating Tidal Current Turbine)

  • 김문오;김유택;이영호
    • 해양환경안전학회지
    • /
    • 제20권5호
    • /
    • pp.586-592
    • /
    • 2014
  • 본 연구에서는 BEMT(Blade Element Momentum Theory)에 의해 우선 정격 출력 100 kW인 수평축 조류 발전용 단일 터빈에대한 기본 형상 설계를 진행하고, CFD 해석을 통해 블레이드 주변 유동특성 파악 및 출력 성능 예측을 하였다. 기본적인 에어포일은 FFA-W3-301, DU-93-W210, NACA-63418을 사용하였다. 이를 바탕으로 상반회전 터빈의 특성을 고찰한 결과, 설계 주속비 5.17에서 최대 출력계수는 0.495이며, 터빈의 출력은 101.82 kW를 얻었다.

SMART-ITL 1 계열 피동안전계통을 이용한 유동분사기 성능에 대한 실험연구 (An Experimental Study on Flow Distributor Performance with Single-Train Passive Safety System of SMART-ITL)

  • 류성욱;배황;양진화;전병국;윤은구;김재민;방윤곤;김명준;이성재;박현식
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.124-132
    • /
    • 2016
  • 노심보충탱크 상부에 설치되는 유동분사기 형상에 따른 냉각수 주입특성 및 탱크 내에서의 열수력 현상 변화를 파악하기 위한 안전주입배관 2인치 파단 소형냉각재상실사고(SBLOCA) 모의시험이 잔열 및 피동잔열제거계통(PRHRS) 모의 없이 수행되었다. 두 가지 형상의 유동분사기를 설치하고 수행한 각각의 시험은 거의 유사한 초기 및 경계조건에서 수행되었으며, 이로 인해 반복시험에 대한 재현성이 충족되었다고 판단된다. 시험결과는 유동분사기의 종류(본 시험에서는 구멍의 개수에 해당)에 관계없이 유사한 열수력학적 거동을 보였으며, 초기 주입유량 관점에서는 구멍의 개수가 2배인 B형이 A형에 비해 좀 더 우수한 주입 성능을 보였다. 노심보충탱크 격리 밸브가 개방된 후 압력평형배관을 통해 유입되는 고온의 원자로냉각재는 상부 헤더에서 상대적으로 저온인 $50^{\circ}C$ 물과 혼합되면서 증기 응축과 같은 상변화에 의한 압력 변동을 동반하는 다차원 열유동 현상을 일으키게 된다. 이로 인해 초반부 노심보충탱크 주입 유량은 상온운전 조건에서 보다는 작게 되고, 일정시간 경과 후에는 유사한 주입유량 특성을 보였다.

분산전원이 연계된 배전계통에서 보호협조기기의 운용특성에 관한 연구 (Operating Characteristics of Protection Coordination Devices in Distribution System interconnected with Distributed Generation)

  • 김소희;지성호;김선영;노대석
    • 한국융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.35-45
    • /
    • 2011
  • 최근 정부의 녹색성장 정책에 의해 배전계통에 태양광, 풍력발전 등과 같은 분산전원의 보급률이 지속적으로 증가되고 있는 실정이다. 이러한 분산전원의 설치가 급증함에 따라 기존 배전계통의 조류흐름은 단방향(One-direction)에서 양방향(Bi-direction)으로 변화되고 고장전류의 증 감이 발생하는 등, 다양한 변화가 생겨 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 양방향 보호협조검토가 가능한 보호협조 평가알고리즘을 제안하고, 그 알고리즘을 바탕으로 양방향 보호협조 평가시스템을 제작하였다. 또한 평가시스템을 이용하여 배전계통을 모델링하고 분산전원 연계 시 보호기기들 사이의 보호협조를 검토하여, 분산전원이 연계된 경우 배전계통에 발생할 수 있는 기술적인 문제점들을 분석하여 그 방안을 제시하였다.

FPD 공정을 위한 램프하우스 열전달 특성 연구

  • 김태안;서원호;김준현;김윤제
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 추계학술대회 발표 논문집
    • /
    • pp.132-137
    • /
    • 2006
  • With the help of the development of digital-multimedia in the middle of 1990's, FDP(Flat Panel Display) had attracted considerable attention. Collimation proximity exposure system that transfers the pattern on wafer or glass exactly using mask and light with appropriate wavelength is core process in semiconductor and liquid display element. The performances of resolution required in precision exposure system are evaluated by resolving power, depth of focus and storage area. Most of development has targeted on these three factors. The optical design including lamp house has played an important role on the performance of exposure process. In this study, we evaluate the cooling system, concerning on exposure device with mercury lamp among the kernel equipment for the production of LCD, to prevent the instability of lighting due to long term accumulation of excessive heating inside the lamp house. Numerical analysis is conducted on full-scale model. The characteristics of three-dimensional flow, pressure and temperature distribution on exposure system are graphically depicted to estimate the whole cooling system for lamp house and to establish the design criteria.

  • PDF