• 제목/요약/키워드: Distribution system losses

검색결과 152건 처리시간 0.031초

CADPAD를 이용한 서인천지역 장.단기 배전계획 (Short and Long Term Distribution Planning of West Inchun using CADPAD)

  • 박창호;김준오;이재봉;정동완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.323-325
    • /
    • 1998
  • Distribution planning needs data of present loads, forecasted loads, sub-stations and distribution lines. Besides it needs a computer program for optimal analysis. In Kepco, The CADPAD system had been used for local distribution planning since 1989. Recently, we upgraded the I/O modules so easy to operate. And they can display optimal feeder planning on a real map. This paper is a case study of the West Inchun distribution planning using the CADPAD system. In this paper, not only optimal feeder designs and sub-station plannings, but also comparison and evaluation of various planning cases are suggested from the viewpoint of voltage drop and line losses.

  • PDF

배전계통 사고복구 문제에 갠선된 유전 알고리즘 적용 (An Application of Enhanced Genetic Algorithm to solve the Distribution System Restoration Problem)

  • 이정관;문경준;황기현;서정일;이화석;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1123-1125
    • /
    • 1999
  • This paper proposes an optimization technique using Genetic Algorithm(GA) for service restoration in the distribution system. Restoration planning problem can be treated as a combinatorial optimization problem. So GA is appropriate to solve the service restoration problem in the distribution network. But searching capabilities of the GA can be enhanced by developing relevant repairing operation and modifying GA operations. In this paper, we aimed at finding appropriate open sectionalizing switch position for the restoration of distribution networks after disturbances using enhanced GA with repairing operation and modified mutation. Simulation results show that proposed method found the open sectionalizing switches with less out of service area and minimize transmission line losses and voltage drop.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

C계수의 추정오차가 배수관망해석에 미치는 영향 (Effect of C Factor Errors on the Analysis of Water Distribution Systems)

  • 현인환;이철규
    • 상하수도학회지
    • /
    • 제13권2호
    • /
    • pp.23-33
    • /
    • 1999
  • This study is to investigate the effect of C factor errors on the analysis of water distribution systems. For this purpose, an artificial distribution network and a real distribution network were selected as the study networks. Results are as follows. 1. The C factor of a pipe which has small velocity didn't give significant effect on the analysis of a water distribution system. 2. The effect of decreased value of C factors give more influence on the analysis of water distribution systems than that of the increased values. 3. For the C factor calibration, errors of the residual water heads as well as those of the head losses should be considered together. 4. In the analysis of water distribution systems, changes of C factors can give influences only on the nodes which locate behind the pipe. Therefore, this characteristics should be considered in the selection of nodes for the measurement of water heads.

  • PDF

배전계통 최적구성을 위한 카오스 탐색법 응용 (Chaotic Search Algorithm for Network Reconfiguration in Distribution Systems)

  • 이상봉;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.325-332
    • /
    • 2003
  • The loss minimization is one of the most important problems to save the operational cost in distribution systems. This paper presents an efficient method for optimal feeder reconfiguration of distribution systems. Chaos search algorithm (CSA) is used to reconfigure distribution systems so that active power losses are globally minimized with turning on/off sectionalizing switches. In optimization problem, the CSA searches the global optimal solution on the basis of regularity in chaotic motions and easily escapes from local or near optimal solution. The CSA is tested on 15 buses and 32 buses distribution systems, and the results indicate that it is able to determine appropriate switching options for global optimum reconfiguration.

유전알고리즘을 이용한 정전력부하를 갖는 배전계통 선로의 재구성에 관한 연구 (A study on distribution system reconfiguration with constant power load using Genetic algorithms)

  • 문경준;김형수;황기현;이화석;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.71-73
    • /
    • 1995
  • This paper presents an optimization technique using genetic algorithms(GA) for loss minimization in the distribution network reconfiguration. Determining switch position to be opened for loss minimization in the radial distribution system is a discrete optimization problem. GA is appropriate to solve the multivariable optimization problem and it uses population, not a solution. For this reason, GA is attractive to solve this problem. In this paper, we aimed at finding appropriate open sectionalizing switch position using GA, which can lead to minimum transmission losses.

  • PDF

유전 알고리즘을 이용한 배전계통 선로 재구성에 관한 연구 (A Study on distribution system reconfiguration using Genetic algorithms)

  • 문경준;김형수;황기현;이화석;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.488-490
    • /
    • 1995
  • This paper presents an optimization technique using genetic algorithms(GA) for loss minimization in the distribution network reconfiguration. Determining switch position to be opened for loss minimization in the radial distribution system is a discrete optimization problem. GA is appropriate to solve the multivariable optimization problem and it uses population, not a solution. For this reason, GA is attractive to solve this problem. In this paper, we aimed at finding appropriate open sectionalizing switch position using GA, which can lead to minimum transmission losses.

  • PDF

배전계통 재구성 문제를 위한 Harmony Search 알고리즘 응용 (Harmony Search Algorithm for Network Reconfiguration Problem in Distribution Systems)

  • 이상봉;김규호;김철환
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1667-1673
    • /
    • 2009
  • This paper presents a application of new algorithm for feeder reconfiguration problem in distribution systems. Harmony Search (HS) algorithm, which is motivated from the musical performance, is used to reconfigure distribution systems so that active power losses are globally minimized with turning on/off the sectionalizing and the tie-line switches. In optimization processing, the HS algorithm has searching ability for the global optimal solution, simple coding of the iteration procedure, and fast convergence to get the solution. The HS algorithm is tested on 15 buses and 69 buses distribution systems, and the results prove its effectiveness to determine appropriate switching options without the occurrence of any misdetermination in switching and get the minimum power loss.

Comparative Study of Two Congestion Management Methods for the Restructured Power Systems

  • Manikandan, B.V.;Raja, S. Charles;Venkatesh, P.;Mandala, Manasarani
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.302-310
    • /
    • 2011
  • Congestion management is one of the most challenging tasks of a system operator to ensure the operation of transmission system within operating limits. In this paper, cluster/zone method and relative electrical distance (RED) method for congestion management are compared based on the considered parameters. In the cluster/zone method, rescheduling of generation is based on user impact on congestion through the use of transmission congestion distribution factors. In the RED method, the desired proportions of generations for the desired overload relieving are obtained. Even after generation rescheduling, if congestion exists, load curtailment option is also introduced. Rescheduling cost, system cost, losses, and voltage stability parameter are also calculated and compared for the above two methods of congestion management. The results are illustrated on sample 6-bus, IEEE 30-bus, and Indian utility 69-bus systems.

전압, 전류 및 부하 불평형율에 대한 비교 연구 (The Comparison Study for Voltage, Current and Load Unbalance Factor)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권2호
    • /
    • pp.88-93
    • /
    • 2005
  • Most of the LV customer have been applied the distribution system of 3-phase four wire system because of its advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But uneven load distribution or unclean voltage quality has occurred various problems such as de-rating, losses increase and vibration, etc. In this paper, voltage, current and power waveform in the actual fields have measured and analyzed in relation with internationally allowable voltage unbalance limits and compared the current unbalance factor with the load unbalance factor.