Effect of C Factor Errors on the Analysis of Water Distribution Systems

C계수의 추정오차가 배수관망해석에 미치는 영향

  • 현인환 (단국대학교 토목환경공학과) ;
  • 이철규 (단국대학교 토목공학과)
  • Published : 1999.03.15

Abstract

This study is to investigate the effect of C factor errors on the analysis of water distribution systems. For this purpose, an artificial distribution network and a real distribution network were selected as the study networks. Results are as follows. 1. The C factor of a pipe which has small velocity didn't give significant effect on the analysis of a water distribution system. 2. The effect of decreased value of C factors give more influence on the analysis of water distribution systems than that of the increased values. 3. For the C factor calibration, errors of the residual water heads as well as those of the head losses should be considered together. 4. In the analysis of water distribution systems, changes of C factors can give influences only on the nodes which locate behind the pipe. Therefore, this characteristics should be considered in the selection of nodes for the measurement of water heads.