• Title/Summary/Keyword: Distribution system

Search Result 15,332, Processing Time 0.044 seconds

Multi-Agent System and its Applications to the Distribution Automation System (멀티에이젼트 기술의 배전자동화시스템 적용방안)

  • Lim, Il-Hyung;Choi, Myeon-Song;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This paper presents benefits of multi-agent system approach and its application to the distribution automation system. Special attention is devoted to the description of hardware and communication platform used to upgrade the conventional distribution automation system structure. Service restoration of primary distribution system is selected as an example of the multi-agent system application. Application of the algorithm for multi-agent based service restoration technique is disclosed in detail. Real field test in Gochang test center of KEPCO has been performed to establish the feasibility of proposed technique.

IEC 61850 Application in Distribution Automation System (배전자동화 시스템에 IEC 61850 적용 방안)

  • Kim, Taw-Wan;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.687-693
    • /
    • 2011
  • In this paper, problems and solutions are proposed for applying IEC 61850 to Distribution Automation System(DAS). Communication protocol integration in power automation system have issued by IEC standards, IEC 61850 of them has researched for applying IEC 61850 to many areas of power system in spite of that it was made for substation automation system. Especially, DAS is just about to apply IEC 61850 by communication network change from serial to ethernet although DNP 3.0 is used. But it's impossible to apply directly IEC 61850 to DAS by difference of environment which unfixed wide area and separated nodes in power distribution system unlike concept of IEC 61850 is made by Substation Automation System(SAS) environment of limited space. Thus, this paper proposed applications of three types which conceptual, practical, and future to consider problems and solutions when apply IEC 61850 to Ethernet based DAS.

Study on Simulation of a physical distribution system (물류과정(物流過程)에서 물류비용절감(物流費用節減)을 위한 Simulation 연구(硏究))

  • Kim, Man-Sik
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.3 no.2
    • /
    • pp.41-55
    • /
    • 1977
  • The physical distribution system is composed of all the activities associated with getting products from the factory to the consumer through the firm's channels of distribution. An increasing amount of attention has been recently devoted to the component problems associated with distribution system analysis. This paper analyzes effect of system parameters which are safety factor of depot's stock, limitation of direct supply from shop stock to customer and ordering quantity on the physical distribution cost and the evaluated items by the Simulation. The distribution system simulator views system as being composed of three structural entities, presents a case study of a Chemical manufactures and carried on one year computer running.

  • PDF

A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser (차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

State Estimation on the Composite Distribution System with Distributed Generation (분산전원이 포함된 복합배전계통 상태추정)

  • Lim, Jae-Sup;Lee, Koans-Kee;Kwon, Hyung-Seok;Kim, Hong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.206-208
    • /
    • 2002
  • Distributed generation (DG) is predicted to play an increasing role in the electric power system of the near future. Distributed generation is by definition that is of limited size (roughly 10MW or less) and interconnected at the substation, distribution feeder or customer load levels. The effects of generation sources within a distribution network on the system losses are investigated in this paper. WLAV state estimation is performed with the composite distribution system containing DG. Simulations with test cases are performed and the results are presented, using IEEE34 bus radial distribution system.

  • PDF

A technology of realistic multi-media display and odor recognition using olfactory sensors (후각 센서를 이용한 냄새 인식 및 실감형 멀티미디어 표현 기술)

  • Lee, Hyeon Gu;Rho, Yong Wan
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.4
    • /
    • pp.33-43
    • /
    • 2010
  • In this paper, we propose a floral scent recognition using odor sensors and a odor display using odor distribution system. Proposed odor recognition has method of correlation coefficient between sensors that select optimal sensors in floral scent recognition system of selective multi-sensors. Proposed floral scent recognition system consists of four module such as floral scent acquisition module, optimal sensor decision module, entropy-based floral scent detection module, and floral scent recognition module. Odor distribution system consists of generation module of distribution information, control module of distribution, output module of distribution. We applied to floral scent recognition for performance evaluation of proposed sensors decision method. As a result, application of proposed method with floral scent recognition obtained recognition rate of 95.67% case of using 16 sensors while applied floral scent recognition system of proposed sensor decision method confirmed recognition rate of 96% using only 8 sensors. Also, we applied to odor display of proposed method and obtained 3.18 thorough MOS experimentation.

A Study on Voltage Variation in KEPCO Distribution System by Introducing the Wind Power Plant (풍력발전단지가 도입되는 한전 실배전계통의 전압변동에 대한 분석)

  • Hwang, J.S.;Jung, W.J.;Kang, S.S.;Kim, B.S.;Kang, H.S.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.16-18
    • /
    • 2001
  • Recently, a study on operation in parallel between Distributed Generation(DG) unit and power distribution system has been growing interest in power distribution system. But, introducing the DG unit causes the problem due to rising the voltage variation on power distribution system. So, This paper presents the effect of introducing DG unit on distribution system. For this simulation, KEPCO distribution system is used.

  • PDF

Complementary Power Control of the Bipolar-type Low Voltage DC Distribution System

  • Byeon, Gilsung;Hwang, Chul-Sang;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Jong-Yul;Kim, Kisuk;Ko, Bokyung;Kim, Eung-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.786-794
    • /
    • 2015
  • In this paper, a new power control strategy for the bipolar-type low voltage direct current (LVDC) distribution system is being proposed. The dc distribution system is considered as an innovative system according to the increase of dc loads and dc output type distribution energy resources (DERs) such as photovoltaic (PV) systems and energy storage systems (ESS). Since the dc distribution system has many advantages such as feasible connection of DERs, reduction of conversion losses between dc output sources and loads, no reactive power issues, it is very suitable solution for new type buildings and residences interfaced with DERs and ESSs. In the bipolar-type, if it has each grid-interfaced converter, both sides (upper, lower-side) can be operated individually or collectively. A complementary power control strategy using two ESSs in both sides for effective and reliable operation is proposed in this paper. Detailed power control methods of the host controller and local controllers are described. To verify the performances of the proposed control strategy, simulation analysis using PSCAD/EMTDC is being performed where the results show that the proposed strategy provides efficient operations and can be applied to the bipolar-type dc distribution system.

Developing a New Risk Assessment Methodology for Distribution System Operators Regulated by Quality Regulation Considering Reclosing Time

  • Saboorideilami, S.;Abdi, Hamdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1154-1162
    • /
    • 2014
  • In the restructured electricity market, Performance-Based Regulation (PBR) regime has been introduced to the distribution network. To ensure the network stability, this regime is used along with quality regulations. Quality regulation impose new financial risks on distribution system operators (DSOs). The poor quality of the network will result in reduced revenues for DSOs. The mentioned financial risks depend on the quality indices of the system. Based on annual variation of these indices, the cost of quality regulation will also vary. In this paper with regard to reclosing fault in distribution network, we develop a risk-based method to assess the financial risks caused by quality regulation for DSOs. Furthermore, in order to take the stochastic behavior of the distribution network and quality indices variations into account, time-sequential Monte Carlo simulation method is used. Using the proposed risk method, the effect of taking reclosing time into account will be examined on system quality indicators and the cost of quality regulation in Swedish rural reliability test system (SRRTS). The results show that taking reclosing fault into consideration, affects the system quality indicators, particularly annual average interruption frequency index of the system (SAIFI). Moreover taking reclosing fault into consideration also affects the quality regulations cost. Therefore, considering reclosing time provides a more realistic viewpoint about the financial risks arising from quality regulation for DSOs.

Study on Improvement of Overcurernt Relay (OCR)'s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation (분산전원이 도입된 배전계통에 초전도한류기 적용에 따른 과전류계전기 동작향상 연구)

  • Lim, Seung-Taek;Lim, Sung-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.300-304
    • /
    • 2017
  • Due to the introduction of various types of dispersed generations (DGs) with larger capacity in a power distribution system, the short-circuit current is expected to be increased, which more requires for the effective fault current limiting methods. As one of the promising countermeasures, the superconducting fault current limiter (SFCL) has been noticed. However, the decreased fault current by SFCL affects the operation of the overcurrent relay (OCR), representative protective device in a power distribution system. In this paper, the operation of the overcurrent relay due to the application of a SFCL in a power distribution system with DG linked by its bus line was analysed through the short-circuit tests. To analyze the effect of the SFCL application in a power distribution system with DG, the experimental simulated circuits were designed and the short-circuit tests for the power distributed system assembled with the DG, the OCR and the SFCL were carried out. Through the analysis on the short-circuit tests, the application of the SFCL in a power distribution system with DG could be confirmed to be contributed to the operational improvement of overcurrent relay.