• 제목/요약/키워드: Distribution generator

Search Result 545, Processing Time 0.033 seconds

A Comparison Study on Severe Accident Risks Between PWR and PHWR Plants (가압 경수로 및 가압중수로형 원자력 발전소의 중대사고 리스크 비교 평가)

  • Jeong, Jong-Tae;Kim, Tae-Woon;Ha, Jae-Joo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.187-196
    • /
    • 2004
  • The health effects resulting from severe accidents of typical 1,000MWe KSNP(Korea Standard Nuclear Plant) PWR and typical 600MWe CANDU(CANada Deuterium Uranium) plants were estimated and compared. The population distribution of the site extending to 80km for both site were considered. The releaese fraction for various source term categories(STC) and core inventories were used in the estimation of the health effects risks by using the MACCS2(MELCOR Accident Consequence Code System2) code. Individuals are assumed to evacuate beyond 16km from the site. The health effects considered in this comparative study are early and cancer fatality risk, and the results are presented as CCDF(Complementary Cumulative Distribution Function) curves considering the occurrence probability of each STC's. According to the results, the early and cancer fatality risks of PHWR plants we lower than those of PWR plants. This is attributed the fact that the amount of radioactive mateials that released to the atmosphere resulting from the postulated severe accidents of PHWR plants are smaller than that of PWR plants. And, the dominating initiating event of STC that shows maximum early and cancer fatality risk is SGTR(Steam Generator Tube Rupture) for both plants. Therefore, the appropriated actions must be taken to reduce the occurrence probability and the amounts of radioactive materials released to the environment in order to protect the public for both PWR and PHWR plants.

Effect of Transportation Temperature and Treatment Time of Ethylene in the Simulated Export on Ripening and Quality of 'Cheongdobansi' Astringent Persimmon (떫은감 '청도반시' 모의 수출에서 수송 온도와 에틸렌 발생제 투입시기가 과실의 숙성 및 품질에 미치는 영향)

  • Kim, Ji-Young;Kim, Il-Ho;Nam, Hyun-Jin;Park, Young-Hoon;Kang, Jum-Soon;Choi, Young-Whan;Son, Beung-Gu;Lee, Yong-Jae
    • Journal of agriculture & life science
    • /
    • v.51 no.4
    • /
    • pp.79-86
    • /
    • 2017
  • We performed simulations of shipping conditions to export 'Cheongdobansi' astringent persimmon to tropical regions. We stored the fruits at $0^{\circ}C$, $5^{\circ}C$, or $10^{\circ}C$ temperature for 15 days to simulate the transport conditions, and then maintained the fruits at $30^{\circ}C$ for 5 days to simulate the distribution condition. Variables that we focused on are 1) the transport temperature($0^{\circ}C$, $5^{\circ}C$, or $10^{\circ}C$) and 2) the treatment time of ethylene generator(before or after shipping). We examined the ripening ratio and quality of the fruits at the end of the shipping and at that of the distribution. The examination at the end of the shipping showed that all of the fruits were ripened at $10^{\circ}C$ transportation but not ripened at $0^{\circ}C$ or $5^{\circ}C$ transportation in the ethylene treated condition. The untreated fruits were not ripened regardless of the transportation temperature. The examination at the end of the distribution showed that all of the fruits were ripened at $5^{\circ}C$ and $10^{\circ}C$ transportation, while 38.5% of fruits were ripened at $0^{\circ}C$ transportation in the ethylene treated fruits before shipping. The fruits treated after shipping were 63.5% and 59.6% ripened at $0^{\circ}C$ and $5^{\circ}C$ transportation, respectively. Unexpectively, only 19.2 % of fruits treated after shipping ripened at $10^{\circ}C$ transportation.

Broadcast Encryption System Using Secret Sharing and Subset Difference Methods (비밀분산 기법과 Subset Difference 기법을 이용한 브로드캐스트 암호시스템)

  • Lee, Jae Hwan;Park, Jong Hwan
    • Journal of Broadcast Engineering
    • /
    • v.20 no.1
    • /
    • pp.92-109
    • /
    • 2015
  • Broadcast encryption is a cryptographic primitive that allows a sender to securely broadcast a message to a set of receivers. The most influential broadcast encryption system was proposed in 2001 by Naor, Naor, Lotspiech, based on a pseudo-random generator and the Subset Difference (SD) method. In this paper, we suggest a new broadcast encryption system that is based on secret sharing and SD methods. On an efficiency aspect, our system achieves O(r) transmission cost, O($log^2n$) storage cost, and O(1) computational cost for the number n of users and the number r of revoked users. Compared to O(log n) computational cost in the previous SD method, our system has the advantage that it needs only constant-sized computational cost for decryption, regardless of the number n or r. On a security aspect, our system can achieve tighter security reduction than the previous SD method and the gap of security loss is about O(n log n). Moreover, our result shows that it is possible to give the effect of the SD method while using an information-theoretically secure key distribution technique as in the Complete Subtree method.

A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room (X선촬영실 내에서의 공간산란선량 변동에 관한 연구)

  • Oh, Hyun-Joo;Kim, Sung-Soo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

Development and Thermal Distribution of An RF Capacitive Heating Device (유전가열장치의 개발과 온열분포)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh, John-Kyu;Kim, Byung-Soo
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.49-58
    • /
    • 1987
  • Hypertermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to treat malignant tumors has been well established and encouraging clinical results have been obserbed. Unfortunately, however, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We developed the radiofrequency capactive hyperthermia device (Greenytherm-GY8) in cooperation with Yonsei Cancer Center and Green Cross Medical Corporation. It was composed with $8{\sim}10MHz$ RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control PC computer. The thermal profile was investigated in agar phantom, animals and in human tumors, heated with capactivie RF device. Deep and homogeneous heating could be achieved in a large phantom of 25cm diameter and 19cm thick when heated with a pair of 23cm diameter electrodes, coupled to both bases of the phantom, when the size of the two electrodes was not the same, the region near the smaller electrode was preferentially heated. It was, therefore, possible to control the depth of heating by choosing proper size of electrodes. Therapeutic temperature $(42^{\circ}C{\sim}43^{\circ}C)$ could be obtained in the living animal experiments. Indications are that deep heating of humn tumors might be achieved with the capacitive method, provided that subcutaenous fat layer is cooled by temperature controlled bolus and large size of electrodes.

  • PDF

Determination of the Hypocentral Parameters Outside The Seismic Array Using a Single Station of Three-Component (지진관측망 밖의 진원결정과 3-성분 단일 지진관측에 관해서)

  • 김소구;이승규
    • The Journal of Engineering Geology
    • /
    • v.5 no.1
    • /
    • pp.59-74
    • /
    • 1995
  • It is well known that the hypocentral parameters inside the seismic array are well determined using HYPO71PC Programs. These programs, however, do not woik well for the non-evenly distribution of the seismic stations and/or the seismic events outside the seismic array. Furthermore it is very difficult to determine the exact locations of small events in North Korea since there is no seismological data exchange between South and North Koreas. We used the polarization method of the single-station with 3-component in addition to HYPO71PC(IASPEI's Program) in order to determine the source parameters of shallow-focus earthquakes outside the seismic array. First of all, we tested the interior events of the Uisung earthquake, April 14, 1991 and the Mt. Keyryong earthquakes, Feorirary 12, 1994, and two exterior events of W. Pyoungyang earthquake, Noventer 12, 1992, and Yellow Sea earthquake, July 26, 1994 to investigate the convergence and divergence to calculate the source parameters. We have found that the source determination outside the seismic array never converges to the exact location whereas the any events inside the array quickly converge to the exact location. The seismic events outside the array such as two events Vladivostok and East Sea, and the Yellow Sea event are more accurately determined using the polarization method. Estimating the source azimuth is carried out by estimating the polarization direction of the interesting phases and the range estimate is made frum the relative timing of different phases. The polarization method is verified by fmding that the estimates of azimuths and incidence angles by the polarization method are identical with those of the synthetic seismograms of the modellings using the generator program.

  • PDF

An Experimental Study on the Stability of Breakwater Head by the Wave Directional Effects (입사파의 방향성효과에 의한 방파제 제두부의 안정성에 관한 실험적 연구)

  • SOHN Byung-Kyu;KIM Hong-Jin;RYU Cheong-Ro
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.713-719
    • /
    • 2001
  • The aim of this study is to check the application criteria of the conventional techniques and clarify the effects of breaker depth, seabed conditions on the stability in relation to the effects of uncertainty of storm duration and directional irregular waves. The typical damage modes were divided by the direct wave force on the armor unit and by the local scouring around the toe of a breakwater head by the model experiments. The destruction modes are defined, and some criteria on the damage modes and scouring/deposition at the toe of a breakwater head in relating the wave-bottom-structural conditions can be checked using the multi-directonal irregular wave generator system. According to the results, it is emphasized that the 3-D effects on the stability should be analyzed in the design of multi-purpose/function coastal structures in consideration of the evaluation of spatial variation of damage modes and hydraulic characteristics as well as the wave distribution along the structures.

  • PDF

An Experimental Study on the Effect of Combined X-ray and Microwave Hyperthermia on the Rectum and Urinary Bladder of Rats (흰쥐의 직장과 방광에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구)

  • Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.115-128
    • /
    • 1986
  • Hyperthermia can enhance the radiation effect as a synergistic reaction in combined X-ray irradiation and hyperthermia; hyperthermia sensitize radioresistant S-phase cells and inhibit cellular recovery from sublethal damage. We fabricated 100 watts, 2450 MHz microwave applicator for hyperthermia and planned the method and condition of heating and measured the temperature by using Agar phantom as a preliminary test. For biological examination, 102 rats were divided into 4 groups as hyperthermia, X-ray irradiation (6Gy-15Gy), combined X-ray and hyperthermia, and normal control groups. Microscopic examination of the rectum and bladder was done and the results were as followings: 1. The microwave generator with 100 watts, 2450MHz magnetron could be heating up to $40^{\circ}{\sim}50^{\circ}C$ for one hour in living tissue. 2. The thermal distribution in tissue equivalent phantom with microwave can be maintained at $40^{\circ}{\sim}44^{\circ}C$ in area of 3cm in depth and 2-10cm in diameter. 3. In Hyperthermia alone group, there was submucosal edema of the rectum but no histologic change in the urinary bladder was seen. 4. The minimal necrosis of the mucosa was appeared in the rectum and bladder after 15 days of 6 Gy and 8 Gy irradiation respectively. The minimal necrosis of the muscle layer of rectum and bladder was appeared after 15 days of 8Gy and 60days of 10Gy irradiation respectively. 5. In combined group of radiation and hyperthermia, thermal enhancement ratio (calculated at necrosis of mucosa and muscle layer) of rectum and bladder was 1.0, and it suggest that there is no change of tolerance dose of normal rectum and bladder.

  • PDF

A Low Jitter Delay-Locked Loop for Local Clock Skew Compensation (로컬 클록 스큐 보상을 위한 낮은 지터 성능의 지연 고정 루프)

  • Jung, Chae-Young;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.309-316
    • /
    • 2019
  • In this paper, a low-jitter delay-locked loop that compensates for local clock skew is presented. The proposed DLL consists of a phase splitter, a phase detector(PD), a charge pump, a bias generator, a voltage-controlled delay line(VCDL), and a level converter. The VCDL uses self-biased delay cells using current mode logic(CML) to have insensitive characteristics to temperature and supply noises. The phase splitter generates two reference clocks which are used as the differential inputs of the VCDL. The PD uses the only single clock from the phase splitter because the PD in the proposed circuit uses CMOS logic that consumes less power compared to CML. Therefore, the output of the VCDL is also converted to the rail-to-rail signal by the level converter for the PD as well as the local clock distribution circuit. The proposed circuit has been designed with a $0.13-{\mu}m$ CMOS process. A global CLK with a frequency of 1-GHz is externally applied to the circuit. As a result, after about 19 cycles, the proposed DLL is locked at a point that the control voltage is 597.83mV with the jitter of 1.05ps.

Design and Implementation K-Band EWRG Transceiver for High-Resolution Rainfall Observation (고해상도 강수 관측을 위한 K-대역 전파강수계 송수신기 설계 및 구현)

  • Choi, Jeong-Ho;Lim, Sang-Hun;Park, Hyeong-Sam;Lee, Bae-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.646-654
    • /
    • 2020
  • This paper is to develop an electromagnetic wave-based sensor that can measure the spatial distribution of precipitation, and to a electromagnetic wave rain gauge (hereinafter, "EWRG") capable of simultaneously measuring rainfall, snowfall, and wind field, which are the core of heavy rain observation. Through this study, the LFM transmission and reception signals were theoretically analyzed. In addition, In order to develop a radar transceiver, LFM transceiver design and simulation were conducted. In this paper, we developed a K-BAND pulse-driven 6W SSPA(Solid State Power Amplifiers) transceiver using a small HMIC(Hybrid Microwave Integrated Circuit). It has more than 6W of output power and less than 5dB of receiving NF(Noise Figure) with short duty of 1% in high temperature environment of 65 degrees. The manufactured module emits LFM and Square Pulse waveform with the built-in waveform generator, and the receiver has more than 40dB of gain. The transceiver developed in this paper can be applied to the other small weather radar.