• Title/Summary/Keyword: Distribution cables

Search Result 206, Processing Time 0.023 seconds

Effects of Metal Impurtities in Insulation of Distribution Cables on Electrical Conduction of Distribution Cables (배전 케이블의 절연체내 불순물이 전기전도도에 미치는 영향)

  • 이우선;김남오;정용호;최재곤;김형곤;김상준
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.447-452
    • /
    • 1997
  • Effects of metal impurities in insulation of distribution cables on electrical conduction of distribution cables was investigated. Samples of Al, Cu, Fe are fabricated as metallic impurities, and measured electrical conductivity in the voltage range of 0~10 KV. Temperature dependent effect of hysteresis curves and the relationship between forward and reverse current due to impurity content are discussed.

  • PDF

A Review of Strategy to Capture Niche Marketing of HTS Power Distribution Cable

  • Park, Sang-Bong;Nam, Kee-Young;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Ryoo, Hee-Suk
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.11-17
    • /
    • 2004
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cables in domestic areas. This paper presents possible strategy of an HTS distribution cables for distributing electric power in local areas as niche marketing. Reflected were its important distinction such as system configuration, rationale, establishment of strategy and considerably high economical efficiency compared with present underground cables. In this paper, applicable important items by using HTS distribution cables in water pumping powerhouse and distribution substation as example objective regions were reviewed. Based on this, the following items on distribution HTS system are examined. (I)A review of constructing a model system to introduce high temperature superconducting distribution cables to objective areas is presented. (2)The strategy to capture HTS distribution cable in water pumping powerhouse and distribution substation as niche marketing regions were reviewed. (3)In concrete, system configuration, rationale, establishment of strategy and considerably high economical efficiency are reviewed between existing cable and HTS one.

Insulation Diagnostics of Power Cables and Application to Real Distribution System (케이블 절연열화진단과 실 계통 적용)

  • Yi, Dong-Young;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

Analysis of Frequency Response Characteristic Considering Semiconducting Screen in Underground Distribution Cables (지중배전케이블에서 반도전층을 고려한 주파수 응답 및 전파특성 분석)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1091-1098
    • /
    • 2012
  • This paper describes frequency response and propagation characteristics considering semiconducting screen in distribution cables. In CIGRE WG 21-05, Simplified Approach(SA) and Rigorous Approach(RA) which can revise the permittivity considering semiconducting screen propose for more detailed EMTP model and frequency dependant analysis. In this paper, the frequency dependent characteristics of complex permittivity are variously analysed by cole-cole function of RA. The attenuation, propagation velocity and surge impedance according to frequency range(1 kHz to 500 MHz) and cable length are also analysed by SA and EMTP simulation in distribution cables. The propagation velocity considering semiconducting screen is slower, and it is saturated over the range of 1 MHz. The signal is significantly attenuated as frequency range is high.

Characterization of Undergrounded Distribution Cables - Chemical Structural Defects, Impurities, Degree of Crosslinking and Shrinkage (지중배전 케이블의 특성분석 - 화학구조결함, 불순물, 가교도, 수축율 -)

  • 김종은;고정우;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.130-134
    • /
    • 1997
  • The structural defects, impurities, degree of crosslinking and shrinkage of 38 field-aged distribution cables have been analyzed. For the comparison of data, 9 new cables were also subjected to an analysis. It is observed that the structural defects and degree of crosslinking show a radial profile. The structural defects are different depending on the manufacturer. A large amount of impurities is present in the insulation shield, which hold true for the new cables manufactured recently. The degree of crosslinking near both shields is lower than that at the central region of the insulation layer. It was also found that, in some cal)toes, the ins난lation was not fully crosslinked. The shrinkage of field-aged cables is higher than that of new cables.

  • PDF

The characteristics of the multi-span suspension bridge with double main cables in the vertical plane

  • Zhang, Li-Wen;Xiao, Ru-Cheng;Jiang, Yang;Chai, Sheng-Bo
    • Structural Engineering and Mechanics
    • /
    • v.42 no.3
    • /
    • pp.291-311
    • /
    • 2012
  • The multi-span suspension bridge having double main cables in the vertical plane is investigated regarding endurance of live load distribution in the case of non-displaced pylon and pylon displacement. The coefficient formula of live load distribution described as the ratio of live load on the bottom cable to the top cable is obtained. Based on this formula, some function in respect of this bridge are derived and used to analyze its characteristics. This analysis targets the cable force, the cable sag and the horizontal displacement at the pylon top under live load etc. The results clarified that the performance of the live load distribution and the horizontal force of cables in the case of non-deformed pylon has a similar tendency to those in the case of deformed pylon, and the increase of pylon rigidity can increase live load distributed to the bottom cable and slightly raise the cable horizontal force under live load. However, effect on the vertical rigidity of bridge and the horizontal force increment of cables caused by live load is different in the case of non-deformed pylon and deformed pylon.

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

Development of Waterproof Jacket Materials for Power Cables

  • Han, Yong-Huei;Jung, Jong-Wook;Kwon, Tae-Ho;Song, Hyun-Seok;Koo, Kyo-Sun;Han, Byung-Sung
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.146-154
    • /
    • 2003
  • This paper describes various characteristics of the new compounds for cable jackets and model cables advanced in waterproof performance in order to essentially solve the problems of underground (URD) distribution class power cable failures. Several compounds were manufactured by the inclusion of additives to base resins available in Korea and tested for basic property, mechanical and electrical characteristics. Two model cables were created by using the compounds determined in the test as being the most appropriate for new structured model cable jacket material. The waterproof performance and mechanical strength of the new cable jackets were verified by applicable tests. As a result, MDPE and LLDPE compounds were superior as cable jackets in both mechanical and electrical characteristic aspects when compared with conventional PVC. In addition, the model cables composed of the new compounds based on MDPE showed good quality results in the water permeability test.

Characterization of Foreign Undergrounded Distribution Cables (외국 지중배전케이블의 특성분석)

  • 고정우;오우정;김종은;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.428-431
    • /
    • 1997
  • In order to compare with domestic underground distribution cables, the foreign cable which was manufactured in USA, 1982 and has been serviced in field for 13 years was characterized with several tests. Water trees, voids, and convolutions are not found in insulation. In hot oil test, insulation is very clean and there was no separation of insulation and conductor shield. The results of degree of crosslinking, FTIR, and DSC are also usual. Specially, the distribution of OIT is very good, which is different from that of domestic cables. The content of impurities is relatively small. This cables was manufactured with good state and no extraordinary degradation is found.

  • PDF

Aging Diagnosis of Underground Distribution Power Cables Using Breakdown Lifetime Prediction (파괴수명예측을 통한 지중배전용 전력케이블의 열화 진단)

  • Kim, Chung-Bae;Lee, Jung-Bin;Lim, Chang-Sub;Jang, Young-Hak;Lee, Jin;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.222-225
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method. which was to be analyzed non-electrical experiments and synthesized by degradation points. To supplement this method, it was also carried out using several electrical analyses. Breakdown voltages were measured and breakdown lifetimes were Predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorted up to 1/3 times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF