• Title/Summary/Keyword: Distribution Room

Search Result 819, Processing Time 0.023 seconds

Numerical Analysis of Natural Convection inside Spray Coating Room on Temperature Distributions (자연대류를 고려한 스프레이 코팅 룸에서의 온도분포 해석)

  • Kim, Nam Woong;Kim, Bo-Seon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.425-430
    • /
    • 2019
  • Zinc coatings are widely used because of their environmental friendliness and high performance. In general, the coating temperature is a major factor in determining the coating layer thickness and coating quality. In the case of a zinc coating, a uniform and appropriate coating temperature is required. In this study, a thermal flow simulation of the air flow was performed to analyze the temperature distribution of a zinc spray coating room in a natural convection state. Using SolidWorks, modeling was performed for two spray coating rooms, a preheating room, and a drying room, and a thermal flow coupled analysis was performed using ANSYS-FLUENT. As a result of the analysis, the temperature distribution characteristics in the spray coating rooms were determined. It was found that the present temperature was below the target temperature of $25^{\circ}C$. Simulations were conducted for two different boundary conditions (one with a heater added and another with the open part closed). The simulation results show that the method of closing the open part is better than adding the heater.

An Analysis of the Thermal Flow Characteristics in Engine-Room and VTRU in accordance with Application of Thermoelectric Device Cooling System to Prevent Overheating of the Korean Navy Ship VRTU (해군 함정 VRTU의 과열방지를 위한 열전소자 냉각장치의 적용에 따른 기관실 및 VRTU 내부 열 유동특성 분석)

  • Jung, Young In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.610-616
    • /
    • 2020
  • This study conducted joint research with the Navy logistics command ship technology research institute to resolve the occurrence of naval vessel's high-temperature warning and equipment shutdown caused by VRTU overheating during summer operation and the dispatch of troops to equatorial regions. The cooling effect was checked according to the installation of a thermoelectric device cooling system, and heat flow and heat transfer characteristics inside VRTU was analyzed using Computational Fluid Dynamics. In addition, the temperature distribution inside the engine room was assessed through interpretation, and the optimal installation location to prevent VRTU overheating was identified. As a result, the average volume temperature inside the VRTU decreased by approximately 10 ℃ with the installation of the cooling system, and the fan installed in the cooling system made the heat circulation smooth, enhancing the cooling effect. The inside of the engine room showed a high-temperature distribution at the top of the engine room, and the end of the HVAC duct diffuser showed the lowest temperature distribution.

A Study on the Plan Composition of Guest Room Area of the Luxury Resort Hotels in Jeiu-Do (제주도 특급관광호텔의 객실부 평면구성에 관한 연구)

  • 박철민;김학진
    • Korean Institute of Interior Design Journal
    • /
    • no.36
    • /
    • pp.52-59
    • /
    • 2003
  • A guest room section is the most important part of the hotel design. It contributes not only to the marketing but also to the effective distribution of the floor plan. This study is to provide the trends of the plan type of the guest rooms at the luxury resort hotels in Jeju-do through analyzing the typical floor plan type and surveying the area distribution of the guest room section. The purpose of the study is to provide the basic materials for the improvement of the quality of hotel guest rooms in Jeju-do, which is emerging as the international tourism destination of 21C. Here, we make the 13 luxury resort hotels in Jeju-do an subject of the study. They are divided into three grades by the size, quality, and the service.

Estimation of Temperature Distribution in the Refrigerator-Room Using Fuzzy Adaptive Model (퍼지적응모델을 이용한 냉장실 온도분포 추정)

  • 김지관
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.46
    • /
    • pp.159-166
    • /
    • 1998
  • Estimating the temperature distribution of a refrigerator-room is important for preventing the over-refrigeration and improving its operating efficiency. It is also necessary in the realization process of the concentrated refrigeration function which has been provided recently as a generalized function in many refrigerator models. In this paper, we investigate the estimation problem of temperature in refrigerator-room and propose a fuzzy adaptive model. The model is unique in that it employs the concept of the fuzzy dead zone in order to improve the accuracy of estimation. The obtained results are then used for determining the optimal position of a temperature sensor.

  • PDF

A Study on the Type of Plane at Hanok in Haengbok Village (행복마을 한옥의 평면 유형에 관한 연구)

  • Lee, Sang-Sun;Sung, Dae-Chul
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.2
    • /
    • pp.27-34
    • /
    • 2012
  • This study aims to examine and classify plane types of Hanok at Haengbok village, analyze changes, area distribution and space structures of space components and sort plane types and their characteristics. Plane types were divided into four; living room, kitchen, dining room, etc. These plane types were labelled as LK type, L+K type, L+DK type and LDK type. LK type and L+K type were mainly found at single-wing house and made of living room and kitchen centered space structure, but substantially they were designed to ensure guest room, room and living room. Therefore, hanok built at Haengbok village were designed to combine the functions of residential function and lodging. Plane type was preferred to be used for double functions of residence and lodging. On the other side, L+DK type and LDK type were mainly found in house with several wings and they were designed centering around living room for family space. In addition entrance was placed to simplify entry from the outside and each room and guest room were arranged to be accessed from living room. It means that the functions of house focused on residence rather than lodging and all rooms had the structure to be used as residential space in case of emergency.

Prediction of Air Movement and Temperature Distribution at Different Store Methods Using 3-D CFD Simulation in Forced-Air Cooling Facility

  • Yang, G.M.;Koh, H.K.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.65-72
    • /
    • 2002
  • Temperature is the most influential environment parameter which affects the quality change of agricultural products in cold storage. Therefore, it is essential to keep the uniform temperature distribution in the storage room. This study was performed to analyze the air movement and temperature distribution in the forced recirculating cold storage facility and to simulate optimum storage method of green groceries using 3-D CFD(three dimensional computational fluid dynamics) computer simulation which applied the standard $textsc{k}$-$\varepsilon$ turbulence model and FVM(finite volume method). The simulation was validated by the experimental results for onion storage and the simulation model was used to simulate the temperature and velocity distribution in the storage room with reference to the change of storage method such as location of storage, no stores, bulk storage, and pallet storage. In case of no stores, internal airflow was circulated without stagnation and consequently air movement and temperature distribution were uniform. In case of bulk storage, air movement was stagnated so much and temperature distribution of onion was not uniform. Furthermore, the inner temperature of onion roses more than the initial temperature of storage. In case of pallet storage, air movement and temperature distribution of onion were so uniform that the danger of quality change was decreased.

  • PDF

A Study on the Diffuser Location for the Reduction of Airborne Infection in Operation Room (수술실내 공기감염억제를 위한 공조용 급배기구 위치 선정에 관한 연구)

  • Kwon, Soonjung;Joo, Youngcheol;Kim, Chun-Sook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2002
  • The air ventilation system of operation rooms has been studied to prevent the cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals were investigated. The distribution of microbe was measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room was developed for the CFD(Computational Fluid Dynamics) analysis. The characteristics of air flow in the empty operation room and in occupied operation room were calculated by using a CFD program. The current diffuser location of an old hospital did not deliver the clean air to the operation part efficiently. A new method to locate diffusers that improve air venting with little increase of the cost of equipment was suggested.

  • PDF

Numerical analysis on the flow field and moisture contamination in a dry room (Dry Room내 기류 및 수분오염에 관한 수치적 연구)

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Jung, Young-Sick
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.865-870
    • /
    • 2000
  • The flow and the moisture contamination of the dry room in the manufacturing process of lithium ion battery are analyzed numerically by finite volume method. Standard ${\kappa}-{\varepsilon}$ turbulent model widely applied in predicting turbulent flow is adopted in this study. Moisture contamination and distribution are studied by assumption of two cases; one-point generation and uniform generation throughout the room. To evaluate ventilation efficiency on moisture contamination, scales of ventilation efficiency are introduced. From these analyses, moisture contamination is strongly dependent on the flow field and the radius of moisture contamination can be reduced by closing a part of outlets in a dry room.

  • PDF

An Experimental Study on the Airflow Characteristics for Clean Tunnel Type Clean Room Design (클린 터널형 클린룸 설계를 위한 유동특성의 실험적 연구)

  • Bae, G.N.;Lim, H.K.;Oh, M.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.32-45
    • /
    • 1989
  • The airflow characteristics of clean tunnel type clean room were experimentally investigated with the change of operating speed and exit type. Distributions of air velocity and pressure were measured in clean room which is located lower than HEPA filters, and the pressure distribution was also measured in upper plenum which is located above the HEPA filters, to identify the performance of clean room. Through the analysis it was turned out that air velocity characteristics in clean room were significantly affected by the upper plenum flow conditions such as pressure distribuion. This results will be useful in the actual clean room design to enhance the performance.

  • PDF

A Study on the Spatial Characteristics of Fork House in the 'Gun-Wi' Area (군위 지역의 민가 특성에 관한 연구 - 화북댐 수몰지역을 대상으로 -)

  • 백영흠;김난아
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.53-57
    • /
    • 2002
  • This is a study on the houses that will be submerged by the construction of hwa-buk dam. The purpose of this study is to record the folk houses that will be disappeared, and to make clear the regional characteristics of folk houses in this area. The type of site plan presents variously according to the location of several important factors. Types of site plan that are presented in this area are 4 (-, \ulcorner, equation omitted, - ), and \ulcorner, type is general. Types of houses according to the number of front room unit are 2. And 3room and 4 room type enlarge the living space by installing the toe-gan. In case of the 4 room-type is having Maru between rooms. The 3 room type shows superior distribution than the 4 room type.

  • PDF