난류유동해석을 통한 환기효율의 수치해석적 연구 (Numerical Analysis of Ventilation Effectiveness using Turbulent Airflow Modeling)

  • 한화택
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.253-262
    • /
    • 1992
  • A numerical procedure is introduced to calculate local ventilation effectiveness using the definitions of local decay rate and local mean age. A low Reynolds number $k-{\varepsilon}$ model is implemented to calculate steady state turbulent velocity distributions, and a step-down method is used to calculate transient concentration distributions. Simulations are carried out for several different values of air change rates and several different diffuser angles in a two-dimensional model of a half scale office room. The results show that the local ventilation effectiveness within a room could vary significantly from one location to another. The nominal air change rate based on the assumption of complete mixing of room air does not provide the local ventilation effectiveness information. It is numerically proved that the local mean age distribution obtained from the transient calculation is equivalent to the steady state concentration distribution with homogeneously distributed contaminant sources.

  • PDF

일개 한방병원 한방응급실 내원환자에 대한 임상적 분석 (Single Hospital-based Clinical Analysis of 1,119 Patients visited Oriental Medical Hospital Emergency Room)

  • 윤다래;이지숙;노현인;이서라;류재환
    • 대한한방내과학회지
    • /
    • 제33권2호
    • /
    • pp.188-196
    • /
    • 2012
  • Objectives : This study was aimed to provide the basic characteristic of patients who visited an Oriental medical hospital emergency room. Methods : We performed a retrospective study on 1,119 patients who visited Kyunghee University Oriental Medical Hospital Emergency Room from June 1, 2011 to March 31, 2012. Results and Conclusions : 1. In distribution of sex, the rate of males was 44.1%, and that of females was 55.9%. The male to female ratio was thus 1:1.26. The patients' average age was 54.64 and the 6th decade of life was the peak age group. 2. Most of the patients visited the Oriental medical hospital emergency room between 11:00 and 23:00. 3. In distribution by days of the week, the most common was Sundays (24.5%), followed by Mondays (16.7%). 4. In the month distribution, the most was December (12.4%), followed by November (10.0%). 5. The patients were grouped as follows: neurological diseases 58.9%, musculoskeletal disease 27.5%, internal medical disease 10.4%, and others 3.2%. 6. Admission rate of patients being treated was 38.8%, and the admission to the intensive care unit (ICU) was 4.5%. of total visiting patients.

표준시험동 바닥충격음 측정위치에 대한 고찰 (Investigation of receiving position in the measurement method for floor impact sound in a testing building)

  • 이신영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

내부발열의 확률적 성상을 고려한 슬래브축냉의 최적제어 (A Study on Optimal Control of Slab Cooling Storage Considering Stochastic Properties of Internal Heat Generation)

  • 정재훈
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.313-320
    • /
    • 2015
  • In this paper, a method to obtain the probability distribution of room temperature and cooling load is presented, when the internal heat generation is applied to the system as a disturbance in the air conditioning system with slab cooling storage. The probability distribution of room temperature and the cooling load due to the disturbance were examined in one room of an office building. When considering only the electric power consumption as a probability component, it was found that the effect on room temperature and cooling load is small, because the probability component of the measured electric power consumption in the building is small. On the other hand, when considering the stochastic fluctuations of electric power consumption together with the heat generated by human bodies, the mean value of the cooling load was about 2,300 W and the ratio of the standard deviations was 19% (10 o'clock in second day). It was revealed that the stochastic effects of internal heat generation acting on the air conditioning system with slab cooling storage are not small.

개구부로 연결된 3중 커플룸의 음향특성 (Acoustic Properties of Three-room Coupled System by Connected Two Apertures)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

철도차량 객차내 오염물질의 분포경향에 관한 전산해석 (Distribution of Pollutant on the Indoor Air of Passenger Car)

  • 소진섭;전철균;박찬수;최주석
    • 한국연소학회지
    • /
    • 제8권2호
    • /
    • pp.7-16
    • /
    • 2003
  • The transfer of air pollutants between passenger room and service room in train are investigated by the computational analysis. The effects of service room temperature, inlet velocity, initial concentration and heating are studied. The flow induced by the difference of density between two rooms is found to take the major role in transfer of polluted air. Low temperature of service room enhances the polluted air flow into passenger room along the floor. Exhaust fan above the door between two rooms is not effective for this case. Strong inlet flow is found to suppress polluted air flow from service room. The heating of passenger room can promote air pollution.

  • PDF

해조류로부터 항고혈압성분의 분리정제 (Separation and Purification of Antihypertensive Substances from Edible Seaweeds)

  • 이승주;하왕현;최혜진;조순영;최종원
    • 한국수산과학회지
    • /
    • 제43권5호
    • /
    • pp.421-427
    • /
    • 2010
  • To isolate natural antihypertensive substances from edible seaweeds, we screened for and separated active compounds contained in natural Underia pinnatifida, cultural Underia pinnatifida, Laminaria japonica, Sporophylls and Agarum cribrosum. They were extracted using room temperature water, boiling water, acetone, and methanol in turn or using room temperature water, ether, acetone, methanol and boiling water in order. The in vitro antihypertensive activity was quantified as inhibitory efficacy against angiotensin-I converting enzyme (ACE), which is a factor inducing hypertension. For all of the seaweeds tested, the fractions soluble in room temperature water and in boiling water showed the strongest ACE inhibitory effect among the extracted fractions. Conversely, the methanol-extracted fractions for all of the seaweeds tested showed no antihypertensive activity. While the ether and acetone fractions had slight antihypertensive effects. The compounds in the aqueous extracts that had antihypertensive activity were presumed to be polysaccharides, such as fucoidan and alginate.

구조-음향 연성계의 민감도해석을 이용한 모형차량의 소음저감에 관한 연구 (A study on the Interior Noise Reduction of Model Car Using the Structural-Acoustic Sensitivity Analysis)

  • 박동철;이장무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.675-680
    • /
    • 1997
  • The object of this study is the numerical analysis about the sound pressure distribution in reverberation rooms. In order to obtain the effect of the boundary conditions of the wall, the sound field was computed for various absorption coefficients and impedances. And the effect of the room shape was investigated by dealing with pentagonal type as well as the rectangular type. In addition an experiment was performed for the sound pressure distribution in a reverberation room and the result was compared with the analysis.

  • PDF

생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석 (Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory)

  • 황지현;홍진관
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.