• 제목/요약/키워드: Distribution Protection

검색결과 1,327건 처리시간 0.032초

태양광 연계 계통의 주파수 보호 기준 정립 (The Frequency Protection of Distribution System with Photovoltaic System)

  • 서훈철;김철환;윤영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

A DRM Framework for Distributing Digital Contents through the Internet

  • Lee, Jun-Seok;Hwang, Seong-Oun;Jeong, Sang-Won;Yoon, Ki-Song;Park, Chang-Soon;Ryou, Jae-Cheol
    • ETRI Journal
    • /
    • 제25권6호
    • /
    • pp.423-436
    • /
    • 2003
  • This paper describes our design of a contents distribution framework that supports transparent distribution of digital contents on the Internet as well as copyright protection of participants in the contents distribution value chain. Copyright protection must ensure that participants in the distribution channel get the royalties due to them and that purchasers use the contents according to usage rules. It must also prevent illegal draining of digital contents. To design a contents distribution framework satisfying the above requirements, we first present four digital contents distribution models. On the basis of the suggested distribution models, we designed a contract system for distribution of royalties among participants in the contents distribution channel, a license mechanism for enforcement of contents usage to purchasers, and both a packaging mechanism and a secure client system for prevention of illegal draining of digital contents.

  • PDF

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • 제3권2호
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

SEQUENTIAL CONFIDENCE INTERVALS WITH ${\beta}-PROTECTION$ IN A NORMAL DISTRIBUTION HAVING EQUAL MEAN AND VARIANCE

  • Kim, Sung-Kyun;Kim, Sung-Lai;Lee, Young-Whan
    • Journal of applied mathematics & informatics
    • /
    • 제23권1_2호
    • /
    • pp.479-488
    • /
    • 2007
  • A sequential procedure is proposed in order to construct one-sided confidence intervals for a normal mean with guaranteed coverage probability and ${\beta}-protection$ when the normal mean and variance are identical. First-order asymptotic properties on the sequential sample size are found. The derived results hold with uniformity in the total parameter space or its subsets.

풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향 (Influence of the Interconnected Wind farm on Protection for Distribution Networks)

  • 장성일;김광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

Application of Fault Location Method to Improve Protect-ability for Distributed Generations

  • Jang Sung-Il;Lee Duck-Su;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Kim Kwang-Ho;Park Yong-Up
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 2006
  • This paper proposes novel protection schemes for grid-connected distributed generation (DG) units using the fault location algorithm. The grid-connected DG would be influenced by abnormal distribution line conditions. Identification of the fault location for the distribution lines at the relaying point of DG helps solve the problems of the protection relays for DG. The proposed scheme first identifies fault locations using currents and voltages measured at DG and source impedance of distribution networks. Then the actual faulted feeder is identified, applying time-current characteristic curves (TCC) of overcurrent relay (OCR). The method considering the fault location and TCC of OCR might improve the performance of the conventional relays for DG. Test results show that the method prevents the superfluous operations of protection devices by discriminating the faulted feeder, whether it is a distribution line where DG is integrated or out of the line emanated from the substation to which the DGs are connected.

Applicability of Messenger Wire for Purpose of Lightning Protection

  • Seo, Hun Chul;Han, Joon;Choi, Sun Kyu;Lee, Byung Sung;Rhee, Sang Bong;Kim, Chul Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 2016
  • The Korean distribution line currently consists of overhead ground wires (OHGW), overhead distribution lines, neutral wires (NW), and messenger wires (MW). The MW is installed under the NW. The lightning protection system in Korea is focused on OHGW and lightning arrester and the MW are not considered. Therefore, this paper proposes the applicability of MW for purpose of lightning protection. For this, we analyzed the effects of lightning overvoltage according to the existence of OHGW and MW and the grounding conditions of the MW in the Korean distribution system. The grounding conditions of the MW that we took into consideration were the common or separate grounding of the MW and NW. The analysis based on the equivalent circuit of the distribution pole at each condition was performed. The distribution lines and lightning were modeled using the Electromagnetic Transients Program (EMTP). For each of the installation conditions of the OHGW and MW, the various lightning conditions were simulated and analyzed for both direct and indirect lightning. The simulation results showed that, if the OHGW was not installed in the Korean distribution system, the lightning overvoltage could be reduced by the common grounding of the MW and NW.

컴퓨터 Simulation을 통한 선체 음극방식(ICCP)의 방식전위분포해석 (An Analysis of the Protective Potential Distribution against Corrosion for Hull ICCP with Computer simulation)

  • 임관진;김기준;이명훈;문경만
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.395-400
    • /
    • 2005
  • The ship hull part is always exposed to severe corrosive environments. Therefore, it should be protected in appropriate ways to reduce corrosion problems. So there are two effective methods in order to protect the corrosion of ship hull. One is the paint coating as a barrier between steel and electrolyte (seawater) and the other is the cathodic protection(CP) supplying protection current. In the conventional design process of the cathodic protection system the required current densities of protected materials have been used. However, the anode position of field or laboratory experiment for obtaining the required current density for CP is significantly different from anode position for real structures. Therefore, the recent CP design must consider the optimum anode position for potential distribution equally over the ship hull. The CP design companies in the advanced countries can obtain the potential distribution results on the cathodic materials by using the computer analysis module. This study would show how to approach the potential analysis in the field of corrosion engineering. The computer program can predict the under protection area on the structure when the boundary condition and analysis procedure are reasonable. In this analysis the polarization curve is converted to the boundary condition in material data.

  • PDF

22.9kV 배전철탑용 아킹혼 설계 (A Development of 22.9kV Arcing Horn for Distribution Line Towers)

  • 오훈;손홍관
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권2호
    • /
    • pp.70-75
    • /
    • 2006
  • Owing to the strike of lightning a breakage of insulator would happen. This breakage may give rise to many problems such as increment of reclosing failure, a drop for reliance and a hardship of maintenance and repair. To solve those problem, this study develop a protected equipment for insulator which is suitable to 22.9[kV] distribution line towers and is purposed to investigation for a Proper adaption, Protection efficiency of insulator and effect of adaption.

국내 지중배전시스템의 서어지 보호방안 (Surge Protection Method of the Underground Distribution System in Korea)

  • 이재봉;정연하;박철배
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.84-88
    • /
    • 2008
  • 본 논문은 2007년에 게재된 "지중배전케이블의 서어지 전파특성 실증연구"를 통해 검증된 서어지 전파특성을 고려하여 피뢰기를 이용한 보호효과를 ATP-EMTP(Electro-Magnetic Transient Program)로 해석하고 국내 상황에 적합한 보호방법을 제시하고자 한다. 국내 지중배전시스템은 입상주에 설치된 피뢰기에 의해 보호되고 있지만 서어지가 케이블의 말단 개방점에서 두배 정도로 상승하여 배전설비의 절연을 위협할 수 있으므로 추가적인 보호 방법이 필요하다. 본 논문에서 추가적인 보호 방법으로 제안하는 스카우트 방법은 입상주 피뢰기 전 후단 전주에 피뢰기를 추가 설치하는 방법으로 지중배전선로에 피뢰기를 설치하기 곤란한 경우나 지중배전선로용 엘보우 피뢰기를 개발하여 적용하는 것보다 경제성에서 유리하고 설치 및 유지보수 측면에서도 효과적일 것으로 기대된다.