• 제목/요약/키워드: Distribution Control Center

검색결과 685건 처리시간 0.027초

Study of Snow Depletion Characteristics at Two Mountainous Watersheds Using NOAA AVHRR Time Series Data

  • Shin, Hyungjin;Park, Minji;Chae, Hyosok;Kim, Saetbyul;Kim, Seongjoon
    • 대한원격탐사학회지
    • /
    • 제29권3호
    • /
    • pp.315-324
    • /
    • 2013
  • Spatial information of snow cover and depth distribution is a key component for snowmelt runoff modeling. Wide snow cover areas can be extracted from NOAA AVHRR or Terra MODIS satellite images. In this study eight sets of annual snow cover data (1997-2006) in two mountainous watersheds (A: Chungju-Dam and B: Soyanggang-Dam) were extracted using NOAA AVHRR images. The distribution of snow depth within the Snow Cover Area (SCA) was generated using snowfall data from ground meteorological observation stations. Snow depletion characteristics for the two watersheds were analyzed snow distribution time series data. The decreased pattern of SCA can be expressed as a logarithmic function; the determination coefficients were 0.62 and 0.68 for the A and B watersheds, respectively. The SCA decreased over 70% within 10 days from the time of maximum SCA.

단독운전 모드 동작에서의 Triple-Active-Bridge 컨버터 제어 기법 및 소신호 모델을 기반으로 한 제어기 설계 (Control Technique of Triple-Active-Bridge Converter and Its Effective Controller Design Based on Small Signal Model for Islanding Mode Operation)

  • 전찬오;허경욱;류명효;정지훈
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.192-199
    • /
    • 2022
  • In DC distribution systems, a TAB converter employing multiple transformers is one of the most widely used topologies due to its high power density, modularizability, and cost-effectiveness. However, the conventional control technique for a grid-connected mode in the TAB converter cannot maintain its reliability for an islanding mode under a blackout situation. In this paper, the islanding mode control technique is proposed to solve this issue. To verify the relative stability and dynamic characteristics of the control technique, small-signal models of both the grid connected and the islanding mode are derived. Based on the small-signal models, PI controllers are designed to provide suitable power control. The proposed control technique, the accuracy of small-signal models, and the performance of the controllers are verified by simulations and experiments with a 1-kW prototype TAB converter.

성인 편마비 환자에서 시각 되먹임과 청각 되먹임이 체중 지지에 미치는 효과 (The Effect of Auditory and Visual Feedback on Symmetric Weight Bearing with Hemiplegia)

  • 박성일;이형훈;신상용
    • 대한물리치료과학회지
    • /
    • 제5권3호
    • /
    • pp.691-696
    • /
    • 1998
  • Objectives : Asymmetrical weight bearing during standing has been identified as a common problem in persons with hemiplegia. This study examined the effect of auditory and visual feedback on symmetric weight bearing with hemiplegia. Method: The intervention program was instituted for 10 min each day with a total of twelve treatment sessions. The machine which was used for this study is the Weight Balancer, OG GIKEN, WB-202, Japan Result: There was a significant improvement of symmetric weight distribution in auditory feedback group whereas the visual feedback group disclosed some improvement but not significantly. There was no significant change in control group. Conclusion: Results of this study suggest that an auditary feedback group can be more effective than visual feedback group or control group in helping the persons with hemiplegia achieve symmetric stance.

  • PDF

Effect of Homogenization Pressure and Supplementation with Sucrose Fatty Acid Ester on the Physical Properties of Dairy Cream-based Emulsions

  • Seo, Chan-Won;Kang, Shin-Ho;Shin, Yong-Kook;Yoo, Byoungseung
    • 한국축산식품학회지
    • /
    • 제38권3호
    • /
    • pp.476-486
    • /
    • 2018
  • In this study, the droplet size distribution, rheological properties, and stability of dairy cream-based emulsions homogenized with different sucrose fatty acid ester (SFAE, a non-ionic small-molecule emulsifier) concentrations (0.08%, 0.16%, and 0.24% w/w) at different homogenization pressures (10 MPa and 20 MPa) were examined. Homogenization at a high pressure resulted in a smaller droplet size and narrower droplet size distribution. The D[4,3] (volume-weighted mean) and D[3,2] (surface-weighted mean) values of the emulsions decreased with an increase in the SFAE concentration. The flow properties of the emulsions homogenized with SFAE showed shear-thinning (n=0.21-0.46) behavior. The apparent viscosity (${\eta}_{a,10}$) and consistency index (K) of the homogenized emulsions were lower than those of the control sample that is non-homogenized and without SFAE, and decreased with an increase in SFAE concentration. The storage modulus (G') and loss modulus (G") of all emulsions homogenized with SFAE were also lower than those of the control sample. The stability of all emulsions with SFAE did not show any significant change for 30 d at $5^{\circ}C$. However, the emulsions stored at $40^{\circ}C$ were unstable over the storage period. Therefore, the addition of SFAE enhanced the stability of dairy cream emulsions during storage at refrigeration temperature ($5^{\circ}C$).

자동차용 공기분배장치의 성능개선에 관한 실험적 연구 (An Experimental Study on Performance Improvement of Automotive Air Handling System)

  • 유성연;이대웅;김진혁
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.622-629
    • /
    • 2007
  • Compact semi-center type automotive air handling system(AHS) is developed in this study and it's performance is compared with the conventional 3-pieces type air hand-ling system. The pressure drop is measured at component level and system level, and air flow rate and air distribution of discharge air through each ducts from air handling system are measured. System level characteristics of pressure drop at face and windshield discharge mode and air flow rate are investigated, and also temperature control linearities are tested. The volume of the air handling system package is reduced about 20%. And air flow rate increase about 5 to 20% compared to the conventional 3-pieces type air handling system at each discharge mode with significantly improved air pressure drop both component and system level. Also, air distribution and temperature controllability meet to evaluation criteria.

Performance Analysis of Opportunistic Spectrum Access Protocol for Multi-Channel Cognitive Radio Networks

  • Kim, Kyung Jae;Kwak, Kyung Sup;Choi, Bong Dae
    • Journal of Communications and Networks
    • /
    • 제15권1호
    • /
    • pp.77-86
    • /
    • 2013
  • Cognitive radio (CR) has emerged as one of effective methods to enhance the utilization of existing radio spectrum. Main principle of CR is that secondary users (SUs) are allowed to use the spectrum unused by primary users (PUs) without interfering PU's transmissions. In this paper, PUs operate on a slot-by-slot basis and SUs try to exploit the slots unused by PUs. We propose OSA protocols in the single channel and we propose an opportunistic spectrum access (OSA) protocols in the multi-channel cognitive radio networks with one control channel and several licensed channels where a slot is divided into contention phase and transmission phase. A slot is divided into reporting phase, contention phase and transmission phase. The reporting phase plays a role of finding idle channels unused by PUs and the contention phase plays a role of selecting a SU who will send packets in the data transmission phase. One SU is selected by carrier sense multiple access / collision avoidance (CSMA/CA) with request to send / clear to send (RTS/CTS) mechanism on control channel and the SU is allowed to occupy all remaining part of all idle channels during the current slot. For mathematical analysis, first we deal with the single-channel case and we model the proposed OSA media access control (MAC) protocol by three-dimensional discrete time Markov chain (DTMC) whose one-step transition probability matrix has a special structure so as to apply the censored Markov chain method to obtain the steady state distribution.We obtain the throughput and the distribution of access delay. Next we deal with the multi-channel case and obtain the throughput and the distribution of access delay by using results of single-channel case. In numerical results, our mathematical analysis is verified by simulations and we give numerical results on throughput and access delay of the proposed MAC protocol. Finally, we find the maximum allowable number of SUs satisfying the requirements on throughput and access delay.

Occlusal deviations in adolescents with idiopathic and congenital scoliosis

  • Zhang, Hao;Ma, Jingbo;Zhang, Zhicheng;Feng, Yafei;Cai, Chuan;Wang, Chao
    • 대한치과교정학회지
    • /
    • 제52권3호
    • /
    • pp.165-171
    • /
    • 2022
  • Objective: This cross-sectional study aimed to investigate the characteristics of malocclusions in scoliotic patients through clinical examinations. Methods: Fifty-eight patients with idiopathic scoliosis (IS) and 48 patients with congenital scoliosis (CS) participated in the study. A randomly selected group of 152 orthopedically healthy children served as the control group. Standardized orthodontic and orthopedic examination protocols were used to record the occlusal patterns and type of scoliosis. Assessments were made by three experienced orthodontists and a spinal surgery team. The differences in the frequency distribution of occlusal patterns were evaluated by the chi-squared test. Results: In comparison with patients showing IS, patients with CS showed a higher incidence of Cobb angle ≥ 45° (p = 0.020) and included a higher proportion of patients receiving surgical treatments (p < 0.001). The distribution of the Angle Class II subgroup was significantly higher in the IS (p < 0.001) and CS (p = 0.031) groups than in the control group. In comparison with the healthy controls, the CS and IS groups showed significantly higher (p < 0.05) frequencies of asymmetric molar and asymmetric canine relationships, upper and lower middle line deviations, anterior deep overbite, unilateral posterior crossbite, and canted occlusal plane, with the frequencies being especially higher in CS patients and to a lesser extent in IS patients. Conclusions: Patients with scoliosis showed a high frequency of malocclusions, which were most obvious in patients with CS.

Extending torsional balance concept for one and two way asymmetric structures with viscous dampers

  • Amir Shahmohammadian;Mohammad Reza Mansoori;Mir Hamid Hosseini;Negar Lotfabadi Bidgoli
    • Earthquakes and Structures
    • /
    • 제25권6호
    • /
    • pp.417-427
    • /
    • 2023
  • If the center of mass and center of stiffness or strength of a structure plan do not coincide, the structure is considered asymmetric. During an earthquake, in addition to lateral vibration, the structure experiences torsional vibration as well. Lateraltorsional coupling in asymmetric structures in the plan will increase lateral displacement at the ends of the structure plan and, as a result, uneven deformation demand in seismically resistant frames. The demand for displacement in resistant frames depends on the magnitude of transitional displacement to rotational displacement in the plan and the correlation between these two. With regard to the inability to eliminate the asymmetrical condition due to various reasons, such as architectural issues, this study has attempted to use supplemental viscous dampers to decrease the correlation between lateral and torsional acceleration or displacement in the plan. This results in an almost even demand for lateral deformation and acceleration of seismic resistant frames. On this basis, using the concept of Torsional Balance, adequate distribution of viscous dampers for the decrease of this correlation was determined by transferring the "Empirical Center of Balance" (ECB) to the geometrical center of the structure plan and thus obtaining an equal mean square value of displacement and acceleration of the plan edges. This study analyzed stiff and flexible torsional structures with one-way and two-way mass asymmetry in the Opensees software. By implementing the Particle Swarm Optimization (PSO) algorithm, the optimum formation of dampers for controlling lateral displacement and acceleration is determined. The results indicate that with the appropriate distribution of viscous dampers, not only does the lateral displacement and acceleration of structure edges decrease but the lateral displacement or acceleration of the structure edges also become equal. It is also observed that the optimized center of viscous dampers for control of displacement and acceleration of structure depends on the amount of mass eccentricity, the ratio of uncoupled torsional-to-lateral frequency, and the amount of supplemental damping ratio. Accordingly, distributions of viscous dampers in the structure plan are presented to control the structure's torsion based on the parameters mentioned.

Tracking Intravenous Adipose-Derived Mesenchymal Stem Cells in a Model of Elastase-Induced Emphysema

  • Kim, You-Sun;Kim, Ji-Young;Shin, Dong-Myung;Huh, Jin Won;Lee, Sei Won;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • 제77권3호
    • /
    • pp.116-123
    • /
    • 2014
  • Background: Mesenchymal stem cells (MSCs) obtained from bone marrow or adipose tissue can successfully repair emphysematous animal lungs, which is a characteristic of chronic obstructive pulmonary disease. Here, we describe the cellular distribution of MSCs that were intravenously injected into mice with elastase-induced emphysema. The distributions were also compared to the distributions in control mice without emphysema. Methods: We used fluorescence optical imaging with quantum dots (QDs) to track intravenously injected MSCs. In addition, we used a human Alu sequence-based real-time polymerase chain reaction method to assess the lungs, liver, kidney, and spleen in mice with elastase-induced emphysema and control mice at 1, 4, 24, 72, and 168 hours after MSCs injection. Results: The injected MSCs were detected with QD fluorescence at 1- and 4-hour postinjection, and the human Alu sequence was detected at 1-, 4- and 24-hour postinjection in control mice (lungs only). Injected MSCs remained more in mice with elastase-induced emphysema at 1, 4, and 24 hours after MSCs injection than the control lungs without emphysema. Conclusion: In conclusion, our results show that injected MSCs were observed at 1 and 4 hours post injection and more MSCs remain in lungs with emphysema.

고밀도 데이터센터의 열환경제어를 위한 수치해석 (Numerical Analysis of Thermal Environment Control in High-Density Data Center)

  • 권오경;김현중;차동안
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.821-828
    • /
    • 2012
  • CPU의 발열량 증가는 서버를 통과하는 배출공기와 유입공기와의 상당한 온도차를 발생시키고 이로 인해 배출공기의 재순환 현상과 유입공기의 바이패스 현상이 발생한다. 이는 데이터센터 냉각시스템의 효율저하를 발생시킨다. 따라서 CRAC의 제어를 통해 유입공기와 배출공기를 분리하는 것이 데이터센터 냉각시스템의 중요한 목표이다. 본 연구에서는 CFD 해석 코드인 ICEPAK을 이용하여 데이터센터에 대한 수치해석을 진행하였다. 실내부로 유입되는 공기유량의 변화에 따른 CPU의 온도와 실 전체의 온도분포를 분석하였다. 이를 통해 CPU의 발열량에 따른 최적 유입유량을 선정하였다. CPU 발열량이 100, 120, 140 W인 경우 유입유량이 $0.15m^3/s$인 지점에서 발열제거와 온도분배가 가장 잘 이루어졌다. RTI 성능지표를 이용하여 해석결과를 검증하였고 RTI 값이 81인 경우 가장 안정적인 결과를 보였다.