• 제목/요약/키워드: Distribution Control Center

검색결과 679건 처리시간 0.026초

배전관제센터의 운전영역 구분을 위한 정량적 업무량 분석 (Quantitative Analysis of Workload for Classifying the Operating Area of Distribution Control Center)

  • 고석일;서동권;최준호;안선주;김현우;윤상윤
    • 전기학회논문지P
    • /
    • 제67권4호
    • /
    • pp.200-207
    • /
    • 2018
  • In recent, KEPCO (Korea Electric Power Corporation) faced difficulties of the DCC (distribution control center) due to the increase of field equipment and operational cost, and aging of operating staffs. In response to these changes in the DCC, KEPCO is trying to change the organization and system of the DCC. In this paper, we present a new attempt to change organization and structure of distribution control center, which was implemented by KEPCO recently. This paper is divided into three major parts. First, to examine the adequacy of the divided basis of current DCCs based on the quantity of installed electrical equipment, we analyzed the correlation between the operational history of the DCCs and the number of equipment. Through the analysis, we confirmed that there is little relationship between the number of equipment and actual workload. Second, we conducted visits and questionnaire surveys of all the DCCs to identify factors affecting the actual workload of distribution operators and then summarized the results. Third, based on this survey, a general formula for analyzing the workload of a DCC was derived, and each DCC's average annual total workload, day/night workload, and required number of personnel were calculated. Through this study, we proposed a more realistic management method of DCCs that can overcome the division criteria based on equipment quantity.

모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성 (Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution)

  • 천준홍;조은빛;유선희;김년옥
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.37-41
    • /
    • 2016
  • 정도관리(Quality Control)는 오차를 최소한으로 하여 검사의 신뢰도를 증진 시키는 것을 목적으로 하고 있으며 이러한 정도관리 활동을 통해 환자의 진단과 치료방침에 영향을 주는 핵의학 혈액 검사의 신뢰도가 확보되고 있다. 이에 연구자들은 신뢰도 향상의 추가적인 기법으로 건강검진 수검자를 대상으로 시행한 핵의학 혈액검사의 모집단 분포를 이용한 통계적 품질관리의 유용성을 평가해 보고자 한다. 2014년 1월부터 2014년 12월까지 서울아산병원 건강증진센터를 이용한 건강검진 수검자 41,341명을 대상으로 핵의학 혈액 검사 12종목에 대해 통계 분석을 시행 하였다. 통계분석은 핵의학 혈액 검사 12종목에 대한 결과 보고 치를 참고치 이내, 참고치 이상, 참고치 이하의 세 가지 그룹의 월간 백분율로 구분하여 모집단 분포의 평균값과 표준편차, 그리고 표준편차 지수(Standard Deviation Index: SDI)를 산출 하였고 그 결과 모집단 분포의 표준편차는 모든 그룹에서 대부분 ${\pm}2SD$ 이내의 결과를 보였다. 건강검진 수검자에 대한 핵의학 혈액검사 12종목(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin)의 모집단 분포를 분석한 결과 월간 백분율의 표준편차 지수(SDI)가 ${\pm}2.0$ 이상인 경우는, 1월과 3월 Insulin검사에서 각각 2.3, 2.4, 5월 Anti-Tg-Ab검사에서 2.2, 그리고 9월 CA19-9에서 2.2의 결과를 보였다. 이는 검사 Kit 시약의 이상 (동위원소 시약의 최대 결합률 저하), 검사반응 시간의 저하가 원인 이었다. 연구대상이 되는 전체의 속성을 포함하고 모집단 분포의 특성을 이용한 통계적 품질관리는 검사실에서 시행하고 있는 내부정도관리 프로그램을 보완하는 역할을 할 수 있으리라 생각된다.

  • PDF

Hardware-in-the-loop Simulation Method for a Wind Farm Controller Using Real Time Digital Simulator

  • Kim, Gyeong-Hun;Kim, Jong-Yul;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Eung-Sang;Lee, Ju-Han;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1489-1494
    • /
    • 2014
  • A hardware-in-the-loop simulation (HILS) method for a wind farm controller using a real time digital simulator (RTDS) is presented, and performance of the wind farm controller is analyzed. A 100 MW wind farm which includes 5 MW wind power generation systems (WPGS) is modeled and analyzed in RSCAD/RTDS. The wind farm controller is implemented by using a computer, which is connected to the RTDS through transmission control protocol/internet protocol (TCP/IP). The HILS results show the active power and power factor of the wind farm, which are controlled by the wind farm controller. The proposed HILS method in this paper can be effectively utilized to validate and test a wind farm controller under the environment in practice without a real wind farm.

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

Real-Time Volt/VAr Control Based on the Difference between the Measured and Forecasted Loads in Distribution Systems

  • Park, Jong-Young;Nam, Soon-Ryul;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.152-156
    • /
    • 2007
  • This paper proposes a method for real-time control of both capacitors and ULTC in a distribution system to reduce the total power loss and to improve the voltage profile over the course of a day. The multi-stage consists of the off-line stage to determine dispatch schedule based on a load forecast and the on-line stage generates the time and control sequences at each sampling time. It is then determined whether one of the control actions in the control sequence is performed at the present sampling time. The proposed method is presented for a typical radial distribution system with a single ULTC and capacitors.

배전 실증시험장에서의 배전자동화 실증시험 결과 (The result on field test of distribution automation in distribution test center)

  • 하복남;윤태상;정영호;조남훈;임성일;강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.182-184
    • /
    • 2000
  • There are several facilities in Kochang distribution test center such as artificial fault generator(AFG), new distribution automation system(NDAS), communication networks (wireless and optic), lumped constant circuit, switches for distribution automation, overhead and underground distribution line. We have been field testing on remote control, data acquisition. remote metering, feeder automation and so on for distribution automation using those equipment.

  • PDF

Time-Dependent Optimal Heater Control Using Finite Difference Method

  • Li, Zhen-Zhe;Heo, Kwang-Su;Choi, Jun-Hoo;Seol, Seoung-Yun
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2254-2255
    • /
    • 2008
  • Thermoforming is one of the most versatile and economical process to produce polymer products. The drawback of thermoforming is difficult to control thickness of final products. Temperature distribution affects the thickness distribution of final products, but temperature difference between surface and center of sheet is difficult to decrease because of low thermal conductivity of ABS material. In order to decrease temperature difference between surface and center, heating profile must be expressed as exponential function form. In this study, Finite Difference Method was used to find out the coefficients of optimal heating profiles. Through investigation, the optimal results using Finite Difference Method show that temperature difference between surface and center of sheet can be remarkably minimized with satisfying Temperature of Forming Window.

  • PDF

Robust Control of Multi-Echelon Production-Distribution Systems with Limited Decision Policy (II)- Numerical Simulation-

  • Jeong, Sang-Hwa;Oh, Yong-Hun;Kim, Sang-Suk
    • Journal of Mechanical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.380-392
    • /
    • 2000
  • A typical production-distribution system consist of three main echelons representing the retailer, distributors, and a factory each with an on-site warehouse. The system is sufficiently general and realistic to represent many industrial situations. However, decision functions and parameters have been selected to apply particularly to the production and distribution of consumer durables. The flows included in the model are materials, orders, and those information flows needed to support the material and order-rate decisions. In this work, a realistic production-distribution system has been used as a basic model, which consists of three sectors: retailer, distributor, and factory. That system is a nonlinear 25th-order continuous system interconnected between the echelons. Using a modern control algorithm, a typical multi-echelon production-distribution system using a dynamic controller is numerically simulated in the nominal plant and in the perturbed plant when the piecewise constant manufacturing decision is limited by a factory manufacturing upper-limit due to capital equipment, manpower, and factory lotsize.

  • PDF

반도체 변압기용 멀티레벨 H-bridge 컨버터에 적용한 간단한 전압 밸런싱 방법 (A Simplified Voltage Balancing Method Applied to Multi-level H-bridge Converter for Solid State Transformer)

  • 정동근;김호성;백주원;조진태;김희제
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.95-101
    • /
    • 2017
  • A simple and practical voltage balance method for a solid-state transformer (SST) is proposed to reduce the voltage difference of cascaded H-bridge converters. The tolerance device components in SST cause the imbalance problem of DC-link voltage in the H-bridge converter. The Max/Min algorithms of voltage balance controller are merged in the controller of an AC/DC rectifier to reduce the voltage difference. The DC-link voltage through each H-bridge converter can be balanced with the proposed control methods. The design and performance of the proposed SST are verified by experimental results using a 30 kW prototype.

Geographic Distribution and Epidemiology of Lung Cancer During 2011 in Zhejiang Province of China

  • Lin, Xia-Lu;Chen, Yan;Gong, Wei-Wei;Wu, Zhao-Fan;Zou, Bao-Bo;Zhao, Jin-Shun;Gu, Hua;Jiang, Jian-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5299-5303
    • /
    • 2014
  • Background: To explore etiology for providing scientific clues for the prevention of lung cancer. Materials and Methods: Data for lung cancer incidence and meteorological geographic factors from 25 counties in Zhejiang province of China during 2011 were studied. Stepwise multiple regression and correlation analysis were performed to analyze the geographic distribution and epidemiology of lung cancer. Results: 8,291 new cases (5,998 in males and 2,293 females) of lung cancer during 2011 in Zhejiang province were reported in the 25 studied counties. Reported and standardized incidence rates for lung cancer were 58.0 and 47.0 per 100,000 population, respectively. The incidence of lung cancer increased with age. Geographic distribution analysis shows that the standardized incidence rates of lung cancer in northeastern Zhejiang province were higher than in the southwestern part, such as in Nanhu, Fuyang, Wuxing and Yuyao counties, where the rates were more than 50 per 100,000 population. In the southwestern Zhejiang province, for instance, in Yueqing, Xianju and Jiande counties, the standardized incidence rates of lung cancer were lower than 37 per 100,000 population. Spearman correlation tests showed that forest coverage rate, air quality index (AQI), and annual precipitation level are associated with the incidence of lung cancer. Conclusions: Lung cancer in Zhejiang province shows obvious regional differences. High incidence appears associated with low forest coverage rate, poor air quality and low annual precipitation. Therefore, increasing the forest coverage rate and controlling air pollution may play an important role in lung cancer prevention.