배전선로 회선별단선도 자동생성 알고리즘 (An Auto-drawing Algorithm for the Single Line Diagram of Distribution Systems)

  • 손주환;임성일
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.854-859
    • /
    • 2010
  • Distribution Automation System(DAS) is designed to improve operational efficiency by acquisition and control of remote data using its components such as central computation units, communication network and feeder remote terminal units. A conventional human machine interface of the DAS adopts a schematic diagram which is made by drawing power equipments on the geographic information system map. The single line diagram is more useful than the schematic diagram for the main tasks of distribution system operation such as protective relay coordination, service restoration and loss minimization. Since the configuration of the distribution line is changed according to the relocation of the open tie switches, the auto-drawing algorithm based on the connection between the sections and the switches is an essential technique. This paper proposes a new auto-drawing algorithm for a single line diagram of distribution systems based on tertiary tree and collision avoidance method. The feasibility of the proposed algorithm has been testified for various cases using practical distribution system with 12 feeders.

능동 데이터베이스를 이용한 배전선로 스위칭 자동화 (Feeder Switch Automation Using Active Database)

  • 최상열;윤창대;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.250-252
    • /
    • 2002
  • Since DAS(Distribution Automation System) has been typically managed for feeder automation in passive manner, it has to be managed by operator when feeder over loadings are detected therefore it may be possible for propagating the over loaded area by operator's mistake. To overcome the defect, The author proposed the feeder switch automation using active database.

  • PDF

배전자동화시스템 통신서비스를 위한 이중화 통신망 보호절체 알고리즘 연구 (A Study on the Protection Switching Mechanism for Distribution Automation System Ethernet Networks Service of Distribution Automation System)

  • 유남철;김재동;오재곤
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.744-749
    • /
    • 2013
  • The protection switching technology is widely adopted in the fiber-optical transmission equipments based on TDM(Time Division Multiplexing), such as PDH, SDH/SONET. A variety of protection switching algorithms for Ethernet networks and the progress of standardization are summarized in the document. There are several kinds of protection switching algorithms for Ethernet networks, such as STP, RSTP, MSTP and etc. However, since Ethernet signal move through detour route, it causes much time to recover. Accordingly, it is difficult to secure a usability of Ethernet networks and QOS(Quality of Service). Also, if the protection switching protocol standardized by IEEE and ITU-T is used, it remains a inherent network switching time for protection. Therefore, a specific protection switching algorithm for Ethernet are needed for seamless and stable operation of Ethernet networks service for Distribution Automation System(DAS). A reliable protection algorithm with no switching delay time is very important to implement Self-healing service for DAS. This study of FPGA based protection switching algorithm for Ethernet networks shows that in case of faults occurrence on distribution power network, immediate fault isolation and restoration are conducted through interaction with distribution equipments using P2P(Peer to Peer) communication for protection coordination. It is concluded that FPGA based protection switching algorithm for Ethernet networks available 0ms switching time is crucial technology to secure reliability of DAS.

신뢰도 비용 최소화를 위한 개폐기의 최적 자동화율 도출에 관한 연구 (Study of Drawing Optimum Switch Automation Rate to Minimize Reliability Cost)

  • 채희석;강병욱;김진석;문종필;김재철
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.297-302
    • /
    • 2015
  • Replacing a manual switch installed in a feeder for a distribution system with an automatic one increases the reliability of the electric power system. This is because the automatic switch can shorten the duration of a fault the customer experiences by splitting the faulty section faster than the manual one does. However, improving the reliability of the distribution system may increase investment costs. Here, the investment costs include automatic switch cost, replacement work cost and labor cost. For this reason, importance should be attached to the proper balance between the increase of the investment costs and the improvement of the reliability of the distribution system. This article analyzed reliability index and economics when manual switches installed in a feeder (RBTS Bus2 model) was replaced by automatic ones. In addition, it attempted to draw the optimum rate of automation of manual switches by automatic ones using the GRG optimization method, considering the current economic requirements.

The Development of Application Programs for Optimal Feeder Operation Through Distribution Automatic System

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jeong, Mi-Ae
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권1호
    • /
    • pp.42-47
    • /
    • 2004
  • This paper presents the various application programs for the Distribution Automation System (DAS) of the Korea Electric Power Corporation (KEPCO)'s distribution system. These programs are developed to allow for optimal operation in the areas of feeder automation, relay coordination, loss minimization and so on. They are single line diagram auto creation programs for the feeder, service restoration program, protection coordination program, data error detection program, and optimal network reconfiguration program. The details of these programs are presented for validity and effectiveness.

Filter 조립 자동화 시스템 설계에 관한 연구 (A Study on the Design of Filter Assembly Automation System)

  • 김홍건
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.111-117
    • /
    • 2008
  • An automation process of filter unit is presented for the application of the assembling procedure and dry furnace work. By that automation procedure, it is expected to enhance working environment such as reducing laboring load, harmful gas, and burning scald. Furthermore, this automation process also minimizes via standardization of manufacturing process so that it may increase productivity and reliability. An automation process of filter unit is presented for the application of the assembling procedure and dry furnace work. Filter automation process also gives a good quality and productivity by simplifying to only one line from the complicated process such as filter cutting$\rightarrow$ adhering$\rightarrow$fabricating in a very small space. It is found that a new conceptual design of dry furnace shows the better quality like uniform heat distribution compared to the conventional design. It is also found that the present design gives a better working environment by adding cooling system.

배전지능화시스템 최적 운영을 위한 통합 데이터베이스 프로그램 설계 (Design of Integrated Database Program for Optimal Operation of Distribution Automation System)

  • 최윤혁;장문종
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.987-993
    • /
    • 2018
  • In the existing distribution automation system, the database is managed by each distribution office. But there is a high possibility to happened a problem during a fault processing because the representation of the connection switches between distribution offices are complicated. In addition, if a distribution office will be going to collapse due to disaster, for example, a big fire or earthquake, its own database may be lost. In order to solve this problem, it is necessary to have a structure of an integrated database management from an integration center to under the distribution office. To do this, the integration center must store and manage it as the database using the own office code.

배전계통의 자동화 운전

  • 현덕화;문홍석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.557-561
    • /
    • 1989
  • This paper presents a new operation method on power distribution system by automated distribution system (ADS). A performance of this automation is established to operate the distribution system faster than earlier. We reduced the period and region of power failure by ADS.

  • PDF

배전용 변압기를 통하여 저압 전원선으로 전파되는 뇌서지 (Lightning Surges Transferred to Low-voltage AC Power Lines through Distribution Transformers)

  • 이복희;이동문;이수봉
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.94-99
    • /
    • 2003
  • 정밀하고 소형화된 전자기기 사용의 증가로 인한 전원공급의 질적 향상에 대한 필요성이 강하게 증가하고 있다. 저압전원 배전계통에서의 과도 과전압은 직격 또는 유도뢰에 의해 유도되어지고, 가정, 사무실, 공장 등의 자동화시스템이나 병원설비와 같은 중요한 시스템의 손상이나 고장의 원인이 되고 있다. 본 논문에서는 임펄스 발생기를 이용하여 배전용 변압기를 거쳐 저압 전원시스템으로 이행되는 뇌과전압의 양상에 대하여 실험적으로 조사하였다. 배전용 변압기의 1차측에 설치한 피뢰기와 수용가측 추가접지는 저압 전원시스템으로 이행되는 뇌서지전압의 제한에는 크게 기여하지 않았다.

디지털 TRS를 이용한 배전자동화통신망 구축 방안 (Design of the digital TRS network for for the Distribution Automation System)

  • 김태경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.420_421
    • /
    • 2009
  • The digital TRS(Trunked Radio System) is an excellent alternative for the transmission medium for the DAS(Distribution Automation System). KEPCO(Korea Electric Power Corporation) made the power IT network with digital TRS system. The main function of the radio network is transmitting and receiving information for the DAS. KEPCO's digital TRS is based on TETRA standard. The digital TRS supports data communication for the electric power control and monitoring systems in various ways.

  • PDF