• 제목/요약/키워드: Distributed Transmission Line

검색결과 99건 처리시간 0.03초

실리콘에 기초한 새로운 크로스바 구조의 손실있는 대칭 결합선로에 대한 유한차분법을 이용한 해석 (Analysis of Symmetric Coupled Line with New Crossbar Embedded on Si-based Lossy Structure using the FDTD Method)

  • Kim, Yoonsuk
    • 한국군사과학기술학회지
    • /
    • 제4권2호
    • /
    • pp.122-129
    • /
    • 2001
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite- Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency- dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

  • PDF

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

최적 전송 선로를 이용한 고효율 분산형 증폭기의 설계 (A Design of High Efficiency Distributed Amplifier Using Optimum Transmission Line)

  • 최흥재;유남식;정용채;김철동
    • 한국전자파학회논문지
    • /
    • 제19권1호
    • /
    • pp.15-22
    • /
    • 2008
  • 본 논문에서는 전송 선로 이론을 기반으로 분산형 증폭기의 역방향 전류 성분을 수식적으로 분석하고, 역방향 전류 성분을 상쇄시켜 최소화하기 위한 최적의 전송 선로의 길이를 구하는 방법을 제시하였다. 기존의 설계방법에서는 역방향 전류 성분을 종단 부하를 통해 단순히 소모시키는 형태이므로 게이트와 드레인 전송 선로의 길이 결정 기준이 설계상에서 뚜렷하게 주어져 있지 않았지만, 제안하는 방법에서는 역방향 전류 성분들이 서로 상쇄가 일어나도록 하는 전송 선로의 길이를 결정하는 이론적 바탕을 제시함으로써 좀 더 체계적인 설계 방법을 제시하고 있다. 제안하는 이론의 검증을 위하여 회로 시뮬레이션을 수행하였고, pHEMT 트랜지스터를 이용하여 차단 주파수가 3.6 GHz인 최적 전송 선로를 이용한 분산형 증폭기를 제작하였다. 측정을 통해 얻은 결과로서 동작 주파수 범위 내에서 최대 이득은 14.5 dB, 최소 이득은 12.8 dB로 측정되었다. 또한, 제안하는 분산형 증폭기의 측정된 효율은 3 GHz에서 25.6 %로 기존의 일반적인 분산형 증폭기에 비해 약 7.6 % 개선되었다. 출력 전력은 일반적인 분산형 증폭기에 비해 약 1.7dB 개선된 10.9 dBm을 얻었다. 이러한 성능 개선은 역방향 전류의 상쇄로 인한 것으로 분석된다.

Negative Group Delay Circuit with Improved Signal Attenuation and Multiple Pole Characteristics

  • Chaudhary, Girdhari;Jeong, Junhyung;Kim, Phirun;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • 제15권2호
    • /
    • pp.76-81
    • /
    • 2015
  • This paper presents a design of a transmission line negative group delay (NGD) circuit with multiple pole characteristics. By inserting an additional transmission line into a conventional NGD circuit, the proposed circuit provides further design parameters to obtain wideband group delay (GD) and to help reduce signal attenuation. As a result, the number of gain compensating amplifiers can be reduced, which can contribute to stable operation when integrated into RF systems. The multiple pole characteristics can provide wider NGD bandwidth and can be obtained by connecting resonators with slightly different center frequencies separated by quarter-wavelength transmission lines. For experimental validation, an NGD circuit with two poles GD characteristic is designed, simulated, and measured.

주기가 다른 격자들로 구성된 DFB 필터의 구현 (Implementation of Distributed Feedback Filters using Cascaded Gratings with Different Period)

  • 호광춘
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.77-82
    • /
    • 2013
  • 주기가 다른 격자들로 구성된 평면 DFB 도파로의 필터 특성들을 등가 전송선로 망을 사용하여 구현하였다. 대역 필터 특성과 공진 특성을 정확하게 분석하기 위하여 Floquet 이론과 Babinet 원리에 기초한 종방향 모드 전송선로 이론 (L-MTLT)을 제시하였다. 수치해석 결과, 본 논문에서 제시한 해석법은 주기가 다른 격자들로 구성된 DFB 도파로의 필터 특성들을 분석하기 위한 간단한 수치 해석적 알고리즘을 제공하였으며, DFB 필터의 대역폭과 사이드로브의 억압특성 각 영역에서의 격자개수와 격자 종횡비 (aspect ratio)에 민감하게 의존함을 보였다.

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

EMTP를 이용한 765kV 송전선로 다상 섬락에 관한 연구 (A Study on Multi-Phase Flashover in 765kV Transmission Line using EMTP)

  • 가복현;민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1586-1588
    • /
    • 1998
  • To use the EMTP, in this paper, a arcing horn is simulated by non-linear resistor and inductor element using TACS, a tower by distributed parameter model, and lines as K. C. Lee model. Changing lightning current characteristics, lightning position, and tower footing resistor value, we analysis multi-phase flashover characteristics in 765 kV transmission line.

  • PDF

A Cross-layer Link Adaptive HD Video Transmission Scheme in WiMedia D-MAC based UWB Systems

  • Joo, Yang-Ick
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1464-1474
    • /
    • 2012
  • In this paper, we propose a QoS (Quality of Service)-aware and cooperative resource reservation scheme using cross-layer link adaptation for wireless high definition video transmission through UWB (Ultra Wide Band) network with D-MAC (Distributed Medium Access Control). A wireless high definition video transmission system usually requires stable high throughput even without line-of-sight, e.g., a destination device in another room separated by a wall. Since the WiMedia D-MAC supporting DRP (Distributed Reservation Protocol) scheme causes lots of DRP resource reservation conflicts due to failure of beacon detection in wireless channel environment, overall performances of the WiMedia D-MAC can be deteriorated. And the current WiMedia MAC standard has not considered QoS provisioning even though QoS parameters such as a range of service rates are provided to each traffic stream. Therefore, we propose Relay DRP protocol with QoS-based relay node selection criterion, which makes a relay path to avoid DRP resource reservation conflicts and guarantee QoS more stably through cross-layer link adaptation of cooperative relay transmission scheme and is compliant with the current WiMedia D-MAC protocol. Simulation results demonstrate performance improvements of the proposed method for throughput and QoS provisioning.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • 제27권5호
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

전송선형 $90^{\cire}$ 정위상기에 관한 연구 (A Study on $90^{\cire}$ Constant Phase Shifter)

  • 이충웅
    • 대한전자공학회논문지
    • /
    • 제13권6호
    • /
    • pp.12-15
    • /
    • 1976
  • 본논문은 현재 AF주파수변역에서 90° 정위상기를 실현하고 있는 방법과는 전혀 다른 착상으로 VHF 고파수대에서 90° 정위상기를 실현하는 새로운 방법을 제시하였다. 이 90° 정위상기의 구조는 간단하며 분포정수소자인 전송선과 집중정수소자인 R.L.C로 용이하게 실현된다. This paper presents the realization method of 90° constant phase shifter in the VHF band, constructed by the entirely differens idea from the conventional method of the realization of constant phase shifter in the audio frequency range. The construction of 90° constant phase shifter is. simple and can be easily realized by using the distributed constant element, transmission line, and the lumped constant elements, R,C,L.

  • PDF