• Title/Summary/Keyword: Distributed Transducer

Search Result 27, Processing Time 0.023 seconds

The Study on the Role of Prostaglandin in Contraction of Vas Deferens (정관운동에 있어서 prostaglandin 의 역할에 관한 연구)

  • Park, Won-Kyoo
    • The Korean Journal of Pharmacology
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 1983
  • Prostaglandin(PG) is ubiquitously distributed in most mammalian tissue and their actions are complicated. Especially in autonomic nervous system, there are evidences indicating that PGs act as neuromodulators i.e., PGs, which are released in the vicinity of autonomic neuroeffector junctions, influence the release and the response of the neurotransmitter. Present study was undertaken to elucidate the interrelationship between $PGF_{2\alpha}$ and adrenergic ${\alpha}_2-receptor$ function in electrical field stimulation induced contractile response of vas deferens in rat. Male rat, weighing 150{\sim}200\;g, was sacrificed and vas deferens was obtained. The isolated vas deferens strip was placed between two platinum electrodes in temperature controlled $(37^{\circ}C)$ muscle chamber containing Tyrode's solution and the electrical field stimulation(EFS) induced contraction was recorded with Grass Polygraph(Model 7) via force displacement transducer (FT .03, Grass). The results are summarized as follows: 1) Electrical field stimulation for 1sec( 1 msec, 40 cps) induced contraction of vas deferens was completely blocked by tetrodotoxin. 2) Bretylium caused marked inhibition of the EFS-induced contraction, hut tyramine and cocaine augmented the contraction. 3) EFS-induced contraction was inhibited or little affected in distal portion of vas deferens by norepinephrine or methoxamine, but the contraction was rather augmented by the ${\alpha}-agonists$ in proximal portion. 4) Clonidine inhibited the EFS-induced contraction proportionally to the concentration in distal portion, which was blocked by yohimbine pretreatment, but in the presence of $PGF_{2\alpha}$ the blockade by yohimbine was reversed. 5) Indomethacin pretreatment reduced the effect of clonidine, but addition of $PGF_{2\alpha}$ after washing-out the indomethacin caused the contraction to the control level. From these results it is suggested that PG synthesis is a necessary step and the PG itself has a permissive role in ${\alpha}_2-adrenoceptor$ action in rat vas deferens.

  • PDF

Hydroacoustic Survey of Spatio-Temporal Distribution of Demersal Fish Aggregations Near the West Coast of Jeju Island, Korea (제주도 서쪽 연안에서 음향자원 조사를 이용한 저층 어군의 시.공간 분포)

  • Kang, Dong-Hyug;Im, Yang-Jae;Lee, Chang-Won;Yoo, Joon-Taek;Myoung, Jung-Goo
    • Ocean and Polar Research
    • /
    • v.30 no.2
    • /
    • pp.181-191
    • /
    • 2008
  • This study aims at assessment of spatio-temporal distribution of demersal fish aggregations near the west coast of Jeju Island using hydroacoustic survey. A 200 kHz split beam transducer attached to a small towed body was used for all acoustic investigations. The received acoustic data were in situ acoustic target strength (TS, dB) for all pings and nautical area scattering coefficient(NASC, $m^2/mile^2$) for 0.1 mile along 12 acoustic transects. Demersal fish aggregations are distributed around the coastal slope having 20 to 30 m depth throughout all seasons. The concentration is higher during the summer season. With regard spatial distribution, higher demersal fish aggregations have been detected near the West coast of Shinchang and especially near Chagwi-do. Pelagic fish aggregations were higher to the south of Chagwi-do during the spring season. Additionally, standing stock of demersal fish aggregations from the NASC data, TS function, and length-weight function of dominant species was estimated as follows: 3.2 ton (CV 21.8%) in December 2006, 17.9 ton (CV 21.6%) in April 2007, 30.8 ton (CV 17.8%) in June 2007, and 22.5 ton (CV 24.2%) in October 2007. The application of hydroacoustic methods offers a new approach to understanding spatiotemporal structure and estimate the biomass of demersal fish aggregations in the coastal area. And the results can be made up limitations of qualitative analysis through net and diving for fisheries resources survey in coastal area.

Effect of Ovum Pick-up Frequency on In Vitro Production of Embryos in Hanwoo Cattle (한우에 있어서 초음파기기를 이용한 생체내 개체별 난자 채취 빈도 및 수정란 생산효율에 관한 연구)

  • 박성재;양보석;임기순;성환후;양병철;장원경;정일정;정기화;심보웅
    • Journal of Embryo Transfer
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • The ultrasound-guided oocytes cllection (ovum pick-up ; OPU) has become a substitution for superovlation in cattle. The objective of this study was to examine the effect of OPU frequency on the in vitro production of embryos in Hanwoo cattle. Six cycling Hanwoo cows were distributed into two groups for either once or twice weekly OPU sessions. Oocytes were collected by ultrasound-guided follicle aspiration(SA600) using a 6.5HMz transducer and attached with 18 gauge needle, with vacuum pressure of 40 mmHg. The cumulus-oocyte complexes (COCs) collected from each donor were matured in TCM 199 supplemented with 10% fetal bovine serum at 5% CO2 in air at 38.5$^{\circ}C$ for 22h and in vitro matured oocytes were co-incubated with sperm(separated by Percoll gradient) for 6h. The zygotes were co-cultured on cumulus cell monolayer in 10ul droplets in the same culture medium and conditions used for IVM for 7 days. On Day 7 of culture, development to blastocysts was examined. Although the number of oocytes collected was variable depending on individuals, overall embryo production in the twice per week OPU sessions was better that in the once per week sessions(6~21 vs 2~7 blastocysts produced, respectively). Two cows(E, A) were good oocyte donors and embryo production was superior in cow C ; however, cow F was a poor donor as compared to the others. In conclusion, these results suggest that for embryo production, twice weekly OPU sessions were better than once per week for producing embryos in vitro from Hanwoo cattle.

  • PDF

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Studies on Estimation of Fish Abundance Using an Echo Sounder ( 1 ) - Experimental Verification of the Theory for Estimating Fish Density- (어군탐지기에 의한 어군량 추정에 관한 기초적 연구 ( 1 ) - 어군량추정이론의 검증실험 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • An experiment has been carefully designed and performed to verify the theory for the echointergration technique of estimating the density of fish school by the use of steel spheres in a laboratory tank. The spheres used to simulate a fish school were randomly distributed throughout the insonified volume to produce the acoustic echoes similar to those scattered from real fish schools. The backscattered echoes were measured as a function of target density at tow frequencies of 50kHz and 200kHz. Data acquisition, processing and analysis were performed by means of the microcomputer-based sonar-echo processor including a FFT analyzer. Acoustic scattering characteristics of a 36cm mackerel was investigated by measuring fish echoes with frequencies ranging from 47.8kHz to 52.0kHz. The fluctuation of bottom echoes caused by the effects of fish-school attenuation and multiple scattering which occurred in dense aggregations of fishes was also examined by analyzing the echograms of sardine schools obtained by a 50kHz telesounder in the set-net's bagnet, and the echograms obtained by a scientific echo sounder of 50kHz in the East China Sea, respectively. The results obtained can be summarized as follows: 1. The measured and the calculated echo shapes on the steel sphere used to simulate a fish school were in close agreement. 2. The waveform and amplitude of echo signals by a mackerel without swimbladder fluctuated irregularly with the measuring frequency. 3. When a collection of 30 targets/m super(3) lied the shadow region behind another collection of 5 targets/m super(3), the mean losses in echo energy for the 30 targets/m super(3) were about -0.4dB at 50kHz and about -0.2dB at 200kHz, respectively. 4. In the echograms obtained in the East China Sea, the bottom echoes fluctuated remarkably when the dense aggregations of fish appeared between transducer and seabed. Especially, in the case of the echograms of sardine school obtained in a set-net's bagnet, the disappearance of bottom echoes and the lengthening of the echo trace by fish aggregations were observed. Then the mean density of the sardine school was estimated as 36 fish/m super(3). It suggests that when the distribution density of fishes in oceans is greater than this density, the effects of fish-school attenuation and multiple scattering must be taken into account as a possible source of error in fish abundance estimates. 5. The relationship between mean backscattering strength (, dB) and target density ($\rho$, No./m super(3)) were expressed by the equations: =-46.2+13.7 Log($\rho$) at 50kHz and =-43.9+13.4 Log($\rho$) at 200kHz. 6. The difference between the experimentally derived number and the actual number of targets gradually decreased with an increase in the target density and was within 20% when the density was 30 targets/m super(3). From these results, we concluded that when the number of targets in the insonified volume is large, the validity of the echo-integration technique of estimating the density of fish schools could be expected.

  • PDF

Inhibitory Effects of ${\gamma}$-Aminobutyric Acid on the Contractility of Isolated Rat Vas Deferens (흰쥐의 적출 정관 수축성에 대한 ${\gamma}$-Aminobutyric Acid의 억제작용)

  • Ahn, Ki-Young;Kwon, Oh-Cheol;Ha, Jeoung-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.382-395
    • /
    • 1992
  • GABA is an inhibitory neurotransmitter in central nervous system and produce sedative, antianxiety and muscle reaxing effects via $GABA_A$ receptor or $GABA_B$ receptor. Recently it is known that GABA is widely distributed throughout peripheral organs and may playa physiological role in certain organ. The vas deferens is innervated by species-difference. These study, therefore, was performed to investigate the mode and the mechanism of action of GABA on the norepiniphrine-, ATP- and electric stimulation-induced contraction of vas deferens of rat. Sprague-Dawley rats were sacrificed by cervical dislocation. The smooth muscle strips were isolated from the prostastic portion and were mounted in the isolated muscle bath. PSS in the bath was aerated with 95/5%-$O_2/CO_2$ at $33^{\circ}C$. Muscle tensions were measured by isometric tension transducer and were recorded by biological recording system. 1. GABA, muscimol, a $GAB_A$ agonist, and baclofen, a $GABA_B$ agonist inhibited the electric field stimulation(EFS, 0.2Hz, 1mSec, 80 V, monophasic square wave)-induced contraction with a rank order of potency of GABA greater than baclofen greater than muscimol. 2. The inhibitory effect of GABA was antagonized by delta aminovaleric acid(DAVA), a $GABA_B$ antagonist, but not by bicuculline, a $GABA_A$ mtagonist. 3. The inhibitory effect of baclofen was antagonized by DAVA, but the effect of muscimol was not antagonized by bicuculline. 4. Exogenous norepinephrine(NE) and ATP contracted muscle strip concentration dependently, but the effect of acetylcholine was negligible : and GABA did not affect the NE-and ATP-induced contractions. 5. GABA, baclofen and muscimol did not affect basal tone, and GABA did not affect the NE-and ATP-induced contractionsm 6. EFS-induced contraction was including 2 distinctable components. The first phasic component was inhibited by beta gamma-methylene ATP(mATP), a desensitizing agent of APT receptor and the second tonic component was reduced by pretreatment of reserpine(3 mg/Kg, IP). 7. GABA inhibited the EFS-induced contraction of reserpinized strips, but not the mATP-treated strips. These results suggest that in the prostatic portion of the rat vas deferens, adrenergic and purinergic neurotransmissions are exist, and GABA inhibits the release of ATP via presynaptic $GABA_B$ receptor on the excitatory neurons.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF