• 제목/요약/키워드: Distributed Impedance

검색결과 155건 처리시간 0.027초

Identification and Damping of Resonances in Inverter-based Microgrids

  • Afrasiabi, Morteza;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1235-1244
    • /
    • 2018
  • The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정 (A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD)

  • ;조기연;변영복;서정일;김은수;김태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

A New Algorithm to Reduce the Mal-Operation of DOCR in Bi-directional Power Distribution Systems

  • Jang, Su-Hyeong;Oh, Joon-Seok;Jeong, Ui-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.585-591
    • /
    • 2016
  • DOCR can be used to efficiently increase the reliability and to protect the bi-directional D/L(Distribution Lines). As more DG(Distributed Generation)s attempt to connect the bi-directional D/L, there is an increasing need for studies of how to use DOCR installed in the D/L. This paper investigates the operating principles of DOCR and presents the results an effect of sequence and fault impedance in L-L(Line to Line) fault. An advanced DOCR operating algorithm is proposed to reduce the mal-operation of conventional DOCR. The proposed algorithm is applied to the bi-directional power flow system and shows that it decreases the mal-operation of DOCR through the computer simulation.

임의의 종단 임피던스를 갖는 3-dB 원형 하이브리드의 집중소자 등가회로를 이용한 소형화에 관한 연구 (A Study on the Miniaturization of 3-dB Ring Hybrid Having Arbitrary Termination Impedance Using Lumped-Equivalent Circuit)

  • 안희란;윤상원;장익수
    • 전자공학회논문지A
    • /
    • 제29A권3호
    • /
    • pp.25-32
    • /
    • 1992
  • In UHF, VHF new design method of samll-sized 3-dB 0$^{\circ}$/180$^{\circ}$ ring hybrid terminated arbitrary impedance using both lumped elements and distributed elements is presented. At the center frequency of 900 MHz, 3-dB 0$^{\circ}$/180$^{\circ}$ ring hybrid terminated arbitrary impedance is designed, analyzed and tested. Good agreements are obtained between measured and theoretical modeling results, and at the same time, the circuit area of hybrid fabricated with two dimensional parallel coupled line, distributed elements and lumped elements is reduced by more than 70% compared with only distribyted-type circuits.

  • PDF

불균일분포 RC소자에 의한 정편각구동점 임피이던스의 최적실현 (Optimal Realization of Constnat-Argumet Driving-Point Impedance Using a Nonuiform Distributed RC Element)

  • 박송배
    • 대한전자공학회논문지
    • /
    • 제12권5호
    • /
    • pp.19-24
    • /
    • 1975
  • 불균일분포 RC소자와 집중 RC소자를 병용한 간단한 회로구성에 의하여 구동점임피치던스가 일정편각 θo을 값도록 실현하는 문제를 고찰하였다. 분포소자의 형상과 집중소자의 값을 조직적으로 변화시키면서 오차를 최소로 하는 최적설계법을 적용하였다. 그 결과 θo=30°, -60°의 경우에는 주파수가 1 : 100의 범위에서 편각오차 2.5° 내외의 것을, 또 θo=-45°의 경우에는 어떤 낮은 주파수이상의 전주파수범위에서 매우 평저한 주파수 특성을 얻을 수 있었다. The problem of realizing a driving-Point impedance, the argument, θo, of which is as constant as possible over a given frequency reange was considered. An optimal design technique was applied by varying systematically the shape of the distributed element and the parameter values of the lumped elements. As a result it was possible to make the argument over two decades of frequencies within-2.5° for θo=- 30° and -60° and very flat above a certain frequency for θo=-45°.

  • PDF

불균등 임피던스 선로를 갖는 인버터기반 분산전원의 부하전압 불평형을 보상하는 드룹 제어 (Droop Control to Compensate Load Voltage Unbalance for Inverter-based Distributed Generations with Unequal Impedance Lines)

  • 양원모;김현준;한병문
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1193-1203
    • /
    • 2016
  • This paper proposes a droop control scheme to compensate the unbalanced line-to-line voltage of unbalanced 3-phase load which is coupled with two inverter-based distributed generations through unequal impedance lines. Unbalanced line-to-line load voltages occur due to using single-phase loads, which brings about bad effects on the coupled inverters and the distributed generations. In order to compensate the unbalanced line-to-line voltages, a positive sequence voltage control was used for sharing the active and reactive power and a negative sequence control was used for reducing the negative sequence voltage. The feasibility of the proposed scheme was first verified by computer simulations, and then experiments with a hardware set-up built in the lab. The experimental results were compared with the simulation results to confirm the feasibility of the proposed scheme.

맥동관 냉동기에서 관성관의 모델링에 관한 연구 (A study on the modeling of the inertance tube in the pulse tube refrigerator)

  • 남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, the inertance tube is modeled by the distributed impedance model. This model is verified by the analytical solutions for the long tube without the reservoir. In this model the distributed impedace effect of the inertance tube is included and mass flow rate and pressure distributions are calculated along the inertance tube for various inertance tube lengths. Mass flow rate at the inlet of the inertance tube is also calculated by this model and compared to the lumped impedance method. Mass flow rate by the distributed model shows quite different behaviors from the lumped model when the operating frequency is high and the length of the tube becomes large.

  • PDF

접지임피던스에 대한 접지봉 크기의 영향 분석 (The Analysis for the grounding impedance influenced by the ground rod's dimension)

  • 이복희;조정현;신희경;이강수;황등과;김정철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.333-336
    • /
    • 2008
  • This paper resents a theoretical analysis for the grounding impedance influenced by the ground rod's dimension using the distributed parameter model. In this paper, EMTP and Matlab Program were used to simulate the distributed parameter model and to analyze the frequency-dependent characteristics of the ground rods. We compared two kinds of ground rods having different dimensions and the frequency-dependent characteristics of two ground rods were quite different from each other. It is estimated that these different characteristics are caused by the distributed parmeters which are changed by the length of ground rod.

  • PDF

Comparison of Impedance Parameters and Occupational Therapy Evaluation in the Paretic and Non-paretic Upper Extremity of Hemiplegic Stroke Patients

  • Yoo, Chan-Uk;Kim, Jaehyung;Hwang, Youngjun;Kim, Gunho;Shin, Yong-Il;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권12호
    • /
    • pp.1980-1991
    • /
    • 2017
  • Many stroke patients undergoing rehabilitation therapy require a quantitative indicator for the evaluation of body function in paretic and non-paretic regions. In this study, the impedance parameters were acquired to assess the physical status in the upper extremity of thirty six stroke patients with hemiplegia caused by cerebral hemorrhage (10 patients) and cerebral infarction (26 patients), using bioelectrical impedance. Prediction marker (PM), phase angle (PA), PM/PA, and resistance (R) versus reactance ($X_c$) were utilized to evaluate the functional status of the paretic and non-paretic regions. In addition, the hand grip strength (HGS) and the pinch strength (lateral, palmer, tip) were measured on the upper extremity of hemiplegic stroke patients. PM was distributed in inversely proportional to HGS, but PA was distributed in proportional to HGS. However, there were a number of patients with HGS of 0, regardless of the impedance parameters (PM, PA, R vs. $X_c$). Paretic and non-paretic status in upper extremity of these patients could not be analyzed using impedance parameters. At the rehabilitation therapist's instructions, they were unable to move the hand and fingers of the paretic upper extremity by cranial nerve damage, motor nerve damage, and severe cognitive decline.

접지임피던스의 변동이 최소가 되는 동축형 탄소접지전극의 길이의 산정 (Determination of the Length of Coaxial Type Carbon Grounding Electrode to Minimize the Fluctuation of Grounding Impedance)

  • 이강수;김종호;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.164-170
    • /
    • 2010
  • For the surge currents like lightning or ground fault currents containing high frequency components which cause the electromagnetic interferences for the electronic devices and communication equipment, the grounding impedances give the significantly composite characteristics which are dependent on the frequency of surge currents. In this paper, the analytical model and method for determining the optimal length of the newly developed coaxial type carbon ground electrode which has a little fluctuation in grounding impedance with frequency. The length of minimizing the fluctuation of grounding impedance by changing frequency from 100[Hz] to 1[MHz] was determined, and the validity of this proposed method was confirmed by comparing with the simulated and measured data.