• Title/Summary/Keyword: Distributed Generations

Search Result 134, Processing Time 0.028 seconds

An Islanding Detection Method for Distributed Generations Using the Voltage Unbalance (전압 불평형율을 이용한 분산전원의 고립운전 검출 기법)

  • Jang S. I.;Park J. K.;Kim K. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.42-44
    • /
    • 2004
  • This paper introduced and proposed the voltage unbalance of DC terminal output as new monitoring parameter for power islanding detection. This paper also presented a simple and novel detection algorithm, which effectively combines the detection results of the conventional parameter, voltage magnitude, and a newly proposed parameter. We tested the proposed method using several distribution network conditions including not only islanding operation conditions, but also non-islanding conditions of normal network load variations. The test results showed that the proposed parameters and algorithm are capable of correctly detecting the islanding operation not affected by variation of DG loading and also have a good selectivity for islanding conditions and non-islanding conditions.

  • PDF

Operating Characteristics of Protection Coordination Devices in Distribution System interconnected with Distributed Generation (분산전원이 연계된 배전계통에서 보호협조기기의 운용특성에 관한 연구)

  • Kim, So-Hee;Ji, Seong-Ho;Kim, Sun-Young;Rho, Dae-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.2
    • /
    • pp.35-45
    • /
    • 2011
  • Recently, with the increasement of the interest about global warming, pollutions, and so on, a number of distributed generations(DGs) such as photovoltaic(PV) and wind power(WP), are interconnected with distribution systems. However, installing of DGs makes power flow changes such as directions, one-direction to bi-direction, and increasing/decreasing of fault current. Therefore, it may cause the critical problems. This paper proposes an evaluation algorithm for bi-directional protection coordination and presents an evaluation system for protection coordination based on this algorithm. Additionally, the result shows that the existing method may cause critical problems, and also the effectiveness of proposed method is verified.

A study on Optimal Operation of Protection Coordination Devices Evaluation System in Distribution System with Distributed Sources (분산전원이 연계된 배전계통에 보호협조기기 평가시스템의 최적운용에 관한 연구)

  • Ji, Sungho;Song, Bangwoon;Kim, Byungki;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2971-2978
    • /
    • 2013
  • Recently, with the world-wide issues about global warming and CO2 reduction, a number of distributed generations(DGs) such as photovoltaic(PV) and wind power(WP), are interconnected with the distribution systems. However, DGs can change the direction of the power flow from one-direction to bi-direction, and also change the direction and amount of fault current of existing distribution systems. Therefore, it may cause the critical problems on the power quality and protection coordination. This paper proposes an operation algorithm for bi-directional protection coordination using and apply it for the evaluation system for protection coordination. From the simulation results It is found that the proposed method is more effective and convenient than existing method.

An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations (분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘)

  • Shin, Dong-Yeol;Kim, Dong-Myung;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

FACTORS AFFECTING AGE STRUCTURES AND GENETIC RESPONSES TO TRUNCATION SELECTION SCHEMES IN A POPULATION WITH OVERLAPPING GENERATIONS

  • Ghaffar, A.;Shimizu, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.4
    • /
    • pp.497-507
    • /
    • 1993
  • Four truncation selection schemes (SSs) were framed to predict and compare the age structures and genetic responses under the influence of various factor employing the scheme-specific algorithms. Two paths of selection, sires (bulls' sires) and dams (bulls' dams) to breed young bulls were considered. Among variable factors, four levels (0.3, 0.5, 0.7, 0.9) of precision of evaluation, five levels (0.0, 0.05, 0.10, 0.15, 0.20 genetic standard deviation) of genetic differences among age classes and 4 levels of proportions selected (for bulls' sire, 0.05, 0.10, 0.125, 0.25, and for bulls' dams 0.02, 0.04, 0.05, and 0.10) contemplated on both paths of selection. The number of age classes for bulls' dams and bulls' sires were 4 or 8 and 2 or 4, respectively. The stayability across age classes for bulls' dams was assumed to be 0.80 or 0.60. The candidates for selection for bulls' sires were equally distributed (0.5 or 0.25) across the age classes. The SS1 (selection on same proportions as candidates' distribution) revealed longest generation lengths and lowest yearly genetic responses. The average ages were youngest and yearly genetic responses were highest in SS4 (selection at each age-specific truncation point with the same average genetic superiority of selected parents across the ages) and followed by SS3 (selection at each agespecific truncation point with same predicted genetic values) and SS2 (selection at common truncation point on phenotypic values) in a population with overlapping generations. The results revealed the importance of choosing suitable selection scheme to acquire maximum yearly genetic responses especially when the genetic differences among age classes are large and the precision of evaluation is relatively low.

Seasonal Fluctuation and Distribution of Obolodiplosis robiniae (Diptera: Cecidomyiidae) Within Crown of Robinia pseudoacacia (Fabaceae) (아까시잎혹파리, Obolodiplosis robiniae (Diptera: Cecidomyiidae) 연간 밀도변동과 아까시나무 수관 내 분포)

  • Lee, Jung-Su;Jung, Yu-Mi;Choi, Kwang-Sik;Kim, Il-Kwon;Kwon, Young-Dae;Jeon, Mun-Jang;Shin, Sang-Chul;Choi, Won-IL
    • Korean journal of applied entomology
    • /
    • v.48 no.4
    • /
    • pp.447-451
    • /
    • 2009
  • Locust gall midge (LGM), Obolodiplosis robiniae (Haldeman) (Diptera: Cecidomyiidae), is a cecidomyiid insect forming roll-up galls on leaves of Robinia pseudoacacia Linnaeus (Fabaceae). LGM, known as native to North America, was reported from Korea and Japan in 2002. LGM was observed weekly or biweekly to clarify their voltinism and distribution within the crown of the host tree in two sites of Osan and Siheung in Korea from May to August, 2007. Density of LGM was investigated based on the number of larvae per leaf. Two generations of LGM were observed in Siheung site whereas three generations in Osan site during the present study. The result indicated that LGM had at maximum three generations per year. The density of LGM in Osan was higher in the upper crown of the host trees than middle or lower part. In Siheung, LGMs were distributed more on the exterior of the lower crown than the interior. The average number of larvae per gall was $3.3{\pm}0.1$ and $2.8{\pm}0.1$ individuals per leaf in Osan and Siheung, respectively.

Composite Stock Cutting using Distributed Simulated Annealing (분산 시뮬레이티드 어닐링을 이용한 복합 재료 재단)

  • Hong, Chul-Eui
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.1_2
    • /
    • pp.20-29
    • /
    • 2002
  • The composite stock cutting problem is to allocate rectangular and/or irregular patterns onto a large composite stock sheet of finite dimensions in such a way that the resulting scrap will be minimized. In this paper, the distributed simulated annealing with the new cost error tolerant spatial decomposition is applied to the composite stock cutting problem in MPI environments. The cost error tolerant scheme relaxes synchronization and chooses small perturbations on states asynchronously in a dynamically changed stream length to keep the convergence property of the sequential annealing. This paper proposes the efficient data structures for representation of patterns and their affinity relations and also shows how to determine move generations, annealing parameters, and a cost function. The spatial decomposition method is addressed in detail. This paper identifies that the final quality is not degraded with almost linear speedup. Composite stock shapes are not constrained to convex polygons or even regular shapes, but the rotations are only allowed to 2 or 4 due to its composite nature.

Modeling of Practical Photovoltaic Generation System using Controllable Current Source based Inverter (제어 가능한 전류원 기반의 인버터를 이용한 실제적 태양광 발전 시스템 모델링)

  • Oh, Yun-Sik;Cho, Kyu-Jung;Kim, Min-Sung;Kim, Ji-Soo;Kang, Sung-Bum;Kim, Chul-Hwan;Lee, You-Jin;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1340-1346
    • /
    • 2016
  • Utilization of Distributed Generations (DGs) using Renewable Energy Sources (RESs) has been constantly increasing as they provide a lot of environmental, economic merits. In spite of these merits, some problems with respect to voltage profile, protection and its coordination system due to reverse power flow could happen. In order to analyze and solve the problems, accurate modeling of DG systems should be preceded as a fundamental research task. In this paper, we present a PhotoVoltaic (PV) generation system which consists of practical PV cells with series and parallel resistor and an inverter for interconnection with a main distribution system. The inverter is based on controllable current source which is capable of controlling power factors, active and reactive powers within a certain limit related to amount of PV generation. To verify performance of the model, a distribution system based on actual data is modeled by using ElectroMagnetic Transient Program (EMTP) software. Computer simulations according to various conditions are also performed and it is shown from simulation results that the model presented is very effective to study DG-related researches.

The Generic Attributes of the New Millennial Leaders

  • DAUD, Salina;WAN HANAFI, Wan Noordiana
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.12
    • /
    • pp.455-464
    • /
    • 2020
  • As the millennials continue to mature and enter the workforce, it is important that employers understand what this generation expects from all aspects of their employment and leadership preferences in order to prepare them to be the next millennials leaders. The purpose of this research is to determine the generic attributes of the new millennial leaders in Malaysia. The survey is distributed among executives in the selected government-linked, multinational, and public-sector companies in Malaysia, with 237 (72%) of whom being millennials. Partial least square (PLS-SEM) via software SmartPLS 3.0 was applied to evaluate the measurement model and the structural model. Results from this study indicate that the attributes of the millennials leader are innovative (0.213), inspiration (0.128), and visionary (0.122). Thus, organization can focus on those attributes in preparing the millennials for being the next generation of leaders. This study offers important implications to researchers as well as practitioners, and highlights the leadership attributes that could help in enhancing millennials leadership. This study produces a new millennials leadership attributes model for millennials leaders in Malaysian companies; with millennials becoming the fastest-growing age groups in the organizations, this study will promote effective and efficient skills for the millennials.

Configurations of AC and DC-type Quality Control Center for a New Distribution System FRIENDS

  • Hayashi Yusuke;Saisyo Masaki;Ise Toshifumi;Tsuji Kiichiro
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.497-501
    • /
    • 2001
  • Unbundled power quality service is paid much attention under the circumstances of deregulation and diversification of needs of customers for quality and price of electric power. Moreover, distributed generators (DGs) such as photovoltaic generations and wind turbines will be introduced to distribution system more and more, and reverse flow of active power has possibility to cause new problems in the distribution system such as voltage rise of distribution line and protection problem. Flexible, Reliable and Intelligent Electrical eNergy Delivery System, which is called FRIENDS, has been proposed as one of promising distribution system for such requirements, and intensive studies are under way. One of features of the system is introducing Quality Control Center (QCC) into the system for unbundled power quality service and easy installation of DGs. Two types of QCCs for such purposes are proposed, and simulation results are shown in this paper.

  • PDF