• 제목/요약/키워드: Distortion control

검색결과 888건 처리시간 0.021초

후판 구조의 각변형 예측 및 제어에 관한 연구 (A Study on the Prediction and Control of Angular Distortion in Thick Weldments)

  • 허주호;김상일
    • Journal of Welding and Joining
    • /
    • 제21권5호
    • /
    • pp.518-524
    • /
    • 2003
  • The block assembly of ship consists of a series of heat processes such as cutting, bending, welding, residual stress relaxation and fairing. With the fast development of computers, the thermal elasto-plastic analysis method has become a versatile tool for practical applications in the ship production. If numerical analysis is proved to be an advantageous tool to predict the residual deformation due to various heat processes, the optimum methods which can remove the welding distortion can be presented at each assembly stage, which will result in great progress in improving the accuracy of block assembly. In order to minimize the weld-induced angular distortion in thick weldments, this paper proposes the optimum groove design for various plate thickness as the distortion control method. The validity of this method has been substantiated by a number of numerical simulations and experiments.

후판 구조의 각변형 예측 및 제어에 관한 연구 (A Study on the Prediction and Control of Angular Distortion in Thick Weldments)

  • 김상일
    • 한국해양공학회지
    • /
    • 제22권6호
    • /
    • pp.100-105
    • /
    • 2008
  • The block assembly of ship consists of a series of heat processes such as cutting, bending, welding residual stress relaxation and fairing With the fast development of computers, the thermal elasto-plastic analysis method has become a versatile tool for practical applications in the ship production. If numerical analysis is proved to be an advantageous tool to predict the residual deformation due to various heat processes, the optimum methods which can remove the welding distortion can be presented at each assembly stage, which will result in great progress in improving the accuracy of block assembly. In order to minimize the weld-induced angular distortion in thick weldments, this paper proposes the optimum groove design for various plate thickness as the distortion control method. The validity of this method has been substantiated by a number of numerical simulations and experiments.

종합 고조파 왜율 일정 제어를 위한 삼상 NPC PWM 인버어터의 제어 기법 (The Control Technique of 3 Phase NPC PWM Inverter to control fixed Total Harmonic Distortion)

  • 송언빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.565-567
    • /
    • 1994
  • This paper presents a software based NPC PWM inverter control technique to eliminate the harmonics in the output waveforms of inverter. The proposed control technique is able to keep down total harmonic distortion and significantly improve the performance of the inverter. In the control node where the frequency ratio is 36 and the modulation index is $1.2\sim2.0$, the proposed inverter has been operated wi thin 5% Total Harmonic Distortion.

  • PDF

Comparative Analysis of Current Controls for Boost PFC Converter under Light Load

  • Juil Kim;Yeong-Jun Choi
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권6호
    • /
    • pp.143-151
    • /
    • 2024
  • 본 논문은 부스트 PFC (Power Factor Correction) 컨버터의 경부하시, 컨버터의 인덕터 전류 왜곡을 수학적으로 분석하고 원인을 정의한다. 경부하시 평균 전류 모드제어에서 인덕터 전류가 불연속적으로 도통하게 되어 부정확한 인덕터 전류 평균값이 전류 제어에 반영된다. 예측 전류 모드제어에서는 인덕터 전류에 비해 전류 리플이 상대적으로 커져 전류 왜곡이 심해진다. 또한 모델 예측 전류제어의 경우 인덕터 전류의 첨두치 부근에서 스위치가 OFF된다. 인덕터 전류 왜곡은 total harmonic distortion 증가와 역률 감소를 유발하기 때문에 반드시 해결되어야 한다. 본 논문은 수학적 분석을 기반으로 부스트 PFC 컨버터의 경부하시 전류 왜곡을 완화할 수 있는 설계 절차를 선정한다. 마지막으로 hardware-in-the-loop simulation을 사용하여 경부하시 제어 방법들을 비교분석했다.

인장하중법에 따른 STS 304 다층 맞대기 용접부의 변형 제어 특성에 관한 연구 (A Study on the Distortion Control Characteristics of the STS 304 Multi-pass Butt Weldment by Tensioning Method)

  • 김하근;이동주;신상범
    • Journal of Welding and Joining
    • /
    • 제28권3호
    • /
    • pp.73-78
    • /
    • 2010
  • The purpose of this study is to develop the control technology of the welding distortion caused by Auto NG-GTA(Narrow Gap-GTA) welding process at the STS 304 multi-pass butt weldment. Heat input model for Auto NG-GTA welding process was established and verified by measuring temperature change and molten pool shape at the bead-on-plate weldment. With the heat input model developed, the effect of tension load on the welding distortion at the STS 304 multi-pass butt weldment was evaluated using the thermo-elasto-plastic FE analysis. In accordance with FEA results, the angular distortion and transverse shrinkage sharply decreased with an increase in tension load. This result indicated that tensioning method was an effective countermeasure against the welding distortion of the STS 304 multi-pass butt weldment.

인장하중법에 따른 STS 304 다층 맞대기 용접부의 변형 제어 특성에 관한 연구 (A Study on the Distortion Control Characteristics of the STS 304 Multi-pass Butt Weldment by the Tensioning Method)

  • 김하근;이동주;신상범
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.101-101
    • /
    • 2009
  • The purpose of this study is to develop the control technology of the welding distortion caused by Auto NG-GTA welding process at the STS 304 multi-pass butt weldment. For it, heat input model for Auto NG-GTA welding process was established and verified by measuring temperature change and molten pool shape at the bead-on-plate weldment. With heat input model developed, the effect of the tension load on the amount of welding distortion at the STS 304 multi-pass butt weldment was evaluated using the thermo-elasto-plastic FE analysis. In accordance with FEA results, the angular distortion and transverse shrinkage sharply decreased with an increase in tension load. This result indicates that tensioning method was verified as a countermeasure against the welding distortion of STS 304 multi-pass butt weldment.

  • PDF

Suppression of Leakage Current and Distortion in Variable Capacitance Devices and their Application to AC Power Regulators

  • Katsuki, Akihiko;Oki, Takuya
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.66-73
    • /
    • 2016
  • The quantity of alternating current (AC) leakage and the value of distortion factor in capacitor currents are discussed with regard to a new power component called variable capacitance device (VCD). This component has terminals for controlling its capacitance. Nonlinear dielectric characteristics are utilized in this device to vary the capacitance. When VCD operates in an AC circuit, the AC leakage from this device through direct current (DC) control voltage source increases according to the conditions of DC control voltage and so on. To solve this problem, we propose techniques for suppressing AC leakage. Although VCD has strong nonlinear characteristics, the current through the capacitor is not distorted significantly. The relations between AC leakage and the distortion in current waveforms are investigated. An application example for an AC power regulator is also introduced to evaluate the distortion in waveforms.

Voltage Feedforward Control with Time-Delay Compensation for Grid-Connected Converters

  • Yang, Shude;Tong, Xiangqian
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1833-1842
    • /
    • 2016
  • In grid-connected converter control, grid voltage feedforward is usually introduced to suppress the influence of grid voltage distortion on the converter's grid-side AC current. However, owing to the time-delay in control systems, the suppression effect of the grid voltage distortion is seriously affected. In this paper, the positive effects of the grid voltage feedforward control are analyzed in detail, and the time-delay caused by the low-pass filter (LPF) in the voltage filtering circuits and digital control are summarized. In order to reduce the time-delay effect on the performance of the feedforward control, a voltage feedforward control strategy with time-delay compensation is proposed, in which, a leading correction of the feedforward voltage is used. The optimal leading step used in this strategy is derived from analyzing the phase-frequency characteristics of a LPF and the implementation of digital control. By using the optimal leading step, the delay in the feedforward path can be further counteracted so that the performance of the feedforward control in terms of suppressing the influence of grid voltage distortion on the converter output current can be improved. The validity of the proposed method is verified through simulation and experiment results.

Distortion Control of the Curved Panel Using Elastic Bending Method

  • Kim H. G.;Shin S. B.;Youn J. G.
    • International Journal of Korean Welding Society
    • /
    • 제5권1호
    • /
    • pp.29-34
    • /
    • 2005
  • Finite element analysis (FEA) and experimental studies on an elastic bending method have been performed in order to control the angular distortion at the fillet weldment for curved panel. Process parameters for the elastic bending method such as clamping span and release time were analyzed with reference to welding condition and geometric effect of the curved panel, which can minimize or prevent the angular distortion by producing a proper skin stress to the fillet weldment. The amounts of the angular distortion decrease almost in a linear manner with an increase in the skin stress. The skin stress required for non-angular distortion at the fillet weldment is strongly dependent on the plate thickness, not the heat intensity applied. The clamping span for obtaining uniform skin stress was defined as functions of the plate thickness and length of the free edge. Clamp should be removed after the fillet weldment is cooled down to room temperature for non-angular distortion. Effectiveness of the elastic bending method established was verified by its application to an actual curved panel.

  • PDF

Study on the Influence of Grid Voltage Quality on SVG and the Suppression

  • Yi, Guiping;Hu, Renjie
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.155-161
    • /
    • 2014
  • Industrial Static Var Generator (SVG) is typically applied at or near the load center to mitigate voltage fluctuation, flicker, phase unbalance, non-sine distortion or other load-related disturbance. Special attention is paid to the influence of grid voltage quality on SVG current, the non-sine distortion and unbalance of grid voltage causes not only the AC current distortion and unbalance but also the DC voltage fluctuation. In order to let the inverter voltage contain the fundamental negative sequence and harmonic component corresponding to the grid voltage, a new dual-loop control scheme is proposed to suppress the influence in this paper. The harmonic and negative sequence voltage decomposition algorithm and DC voltage control are also introduced. All these analyses can guide the practical applications. The simulation results verify the feasibility and effectiveness of the present control strategy and analyses.