• 제목/요약/키워드: Distance relaying

검색결과 94건 처리시간 0.03초

SER-Based Relay Selection for Two-Way Relaying with Physical Layer Network Coding

  • Li, Dandan;Xiong, Ke;Qiu, Zhengding;Du, Guanyao
    • ETRI Journal
    • /
    • 제35권2호
    • /
    • pp.336-339
    • /
    • 2013
  • To enhance the symbol error rate (SER) performance of the two-way relay channels with physical layer network coding, this letter proposes a relay selection scheme, in which the relay with the maximal minimum distance between different points in its constellation among all relays is selected to assist two-way transmissions. We give the closed-form expression of minimum distance for binary phase-shift keying and quadrature phase-shift keying. Additionally, we design a low-complexity method for higher-order modulations based on look-up tables. Simulation results show that the proposed scheme improves the SER performance for two-way relay networks.

퍼지추론시스템 기반 지중송전계통 보호용 거리계전 알고리즘 개발 (Fuzzy Inference System Based Distance Relay Algorithm Development for Protecting an Underground Power Cable Systems)

  • 정채균;오성권;박건준;이재규;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.172-178
    • /
    • 2008
  • If the fault occurs on the underground power cable systems, the fault current on the sheath has an influence on all sections of cable because it's returned through earth at the directly grounded point and operation point of SVL(Sheath Voltage Limiter) on each insulated joint box. Therefore, the earth resistance and the operation of SVL have an effect on the zero-sequence current, and then the impedance between relaying point and fault point is increased. That causes the overreach of distance relay. For these reasons, the distance relay algorithm for protecting an underground power cable systems hasn't been developed till now. In this paper, new distance relay algorithm is developed for protecting a underground power cable system using fuzzy inference system which is the one of ACI(Advanced Computational Intelligence) techniques. This algorithm is verified by EMTP simulation of real power cable system, and proves to effectively advance the errors

레일리 페이딩 채널 상에서 기회주의적 증분형 중계기 선택 기법을 기반으로 한 협력 전송 알고리즘 (Cooperative Transmission Protocol based on Opportunistic Incremental Relay Selection over Rayleigh fading channels)

  • 단 디 쉬엔;공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.53-58
    • /
    • 2011
  • 본 논문에서는 새로운 협력 전송 프로토콜을 제안한다. 기존의 협력 전송 프로토콜은 송신단과 수신단 사이에 위치하는 다수의 노드들 중에서 가장 높은 SNR을 가지는 노드를 이용하여 수신단으로 신호를 전송한다. 그러나 본 논문에서 제안하는 협력 전송 프로토콜은 노드의 위치정보를 기반으로 하여 송신단으로부터 복호에 성공한 노드들 중 수신단에 가장 가까운 노드를 선택하여 선택된 노드만이 수신단으로 신호를 전송하게 한다. 본 논문에서 제안하는 위치 정보를 기반으로 하는 중계기 선택 기법을 이용하는 협력 전송 프로토콜에 대해 수학적으로 분석하고 모의실험을 통해 이를 증명한다.

최소자승법을 이용한 적응형 데이터 윈도우의 거리계전 알고리즘 (Distance Relaying Algorithm Based on An Adaptive Data Window Using Least Square Error Method)

  • 정호성;최상열;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.371-378
    • /
    • 2002
  • This paper presents the rapid and accurate algorithm for fault detection and location estimation in the transmission line. This algorithm uses wavelet transform for fault detection and harmonics elimination and utilizes least square error method for fault impedance estimation. Wavelet transform decomposes fault signals into high frequence component Dl and low frequence component A3. The former is used for fault phase detection and fault types classification and the latter is used for harmonics elimination. After fault detection, an adaptive data window technique using LSE estimates fault impedance. It can find a optimal data window length and estimate fault impedance rapidly, because it changes the length according to the fault disturbance. To prove the performance of the algorithm, the authors test relaying signals obtained from EMTP simulation. Test results show that the proposed algorithm estimates fault location within a half cycle after fault irrelevant to fault types and various fault conditions.

웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구 (A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables)

  • 정채균;홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF

ESBL: An Energy-Efficient Scheme by Balancing Load in Group Based WSNs

  • Mehmood, Amjad;Nouman, Muhammad;Umar, Muhammad Muneer;Song, Houbing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권10호
    • /
    • pp.4883-4901
    • /
    • 2016
  • Energy efficiency in Wireless Sensor Networks (WSNs) is very appealing research area due to serious constrains on resources like storage, processing, and communication power of the sensor nodes. Due to limited capabilities of sensing nodes, such networks are composed of a large number of nodes. The higher number of nodes increases the overall performance in data collection from environment and transmission of packets among nodes. In such networks the nodes sense data and ultimately forward the information to a Base Station (BS). The main issues in WSNs revolve around energy consumption and delay in relaying of data. A lot of research work has been published in this area of achieving energy efficiency in the network. Various techniques have been proposed to divide such networks; like grid division of network, group based division, clustering, making logical layers of network, variable size clusters or groups and so on. In this paper a new technique of group based WSNs is proposed by using some features from recent published protocols i.e. "Energy-Efficient Multi-level and Distance Aware Clustering (EEMDC)" and "Energy-Efficient Multi-level and Distance Aware Clustering (EEUC)". The proposed work is not only energy-efficient but also minimizes the delay in relaying of data from the sensor nodes to BS. Simulation results show, that it outperforms LEACH protocol by 38%, EEMDC by 10% and EEUC by 13%.

직접계산을 이용한 상간단락 거리계전 알고리즘 (A Phase-to-Phase Distance Relaying Algorithm Using Direct 3 Phase Calculation)

  • 현승호;이성오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.333_335
    • /
    • 2009
  • It is expected, in the near future, that the use of distributed generation systems should be increased considerably. In this case, distance relay algorithm should be developed in the manner that it can reduce the error due to the in-feed effect. This paper presents a method to consider the fault current rushed from the remote end of a line. In the steady-state, the relays in both ends exchange the voltages of upper nodes. If a fault is perceived, the relay calculates fault location taking the fault current from the remote end by using voltage data of the remote ends obtained just before the fault. Even though this method has inevitable error, it can show more precise fault allocation. The suggested method is applied to a typical transmission system with two power sources in both ends to verify its effectiveness.

  • PDF

Line Security Evaluation of WANS Considering Protectability of Relays and Vulnerability of Lines

  • Hussain, Akhtar;Seok, Chang-Ju;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Seong-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1864-1872
    • /
    • 2014
  • Maloperation of protective relays is one of the major causes for cascading tripping in WANS. Another line trip followed by a previous line trip may occur due to overloading of the line, because of the load redistribution or unwanted trip of a backup relay due to change in the flow of fault current. Evaluation of each line is required by considering both of these effects. A new index named Line Security Index (LSI) is proposed in this paper which combines both Vulnerability Index (VI) and Protectability Index (PI) to completely evaluate the security of individual lines and their importance in the power grid. Computer simulations have been performed on the Korean power grid data to establish the feasibility of the proposed idea.

가공송전선로와 지중송전선로가 연계된 혼합송전선로에서 디지털 거리계전 알고리즘 (A Digital Distance Relaying Algorithm in Combined Transmission Line Connected whth Overhead Line and Underground Cable)

  • 하체웅;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.440-442
    • /
    • 2000
  • This paper describes the digital distance algorithm in case of combined transmission line connected with overhead line and underground cable. Actually as fault is occurred in cable, it results in the complicated phenomena due to the several kind of grounding method in the sheath of cable. Accordingly the impedance. Therefore the correct impedance calculation algorithm is requested in combined transmission line to avoid the wrong trip of relay. This paper presents the development result of impedance calculation algorithm In such transmission line.

  • PDF

ACI 기법을 이용한 지중송전계통 거리계전알고리즘 개발 (Development of Distance Relay Algorithm Using ACI Technique on Underground Power Cable System)

  • 정채균;이종범;노석범;오성권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.676-678
    • /
    • 2005
  • In underground power cable system, the apparent impedance at the relaying point can be changed because of the complicated configuration such as the various earth resistance and the operation of sheath voltage limiter (SVL). They have a bad effect on the distance relay operation Therefore, in this paper, in order to solve this problem, the authors are going to anly the advanced computational technique(ACI) of FR-FIS(Fuzzy Relation-based Fuzzy Inference System).

  • PDF