• 제목/요약/키워드: Distance relaying

Search Result 94, Processing Time 0.032 seconds

Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line (웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.

Neural Network Fault Patterns Estimator for the Digital Distance Relaying Technique (거리계전기법을 위한 신경회로망 고장패턴 추정기)

  • Jung, H.S.;Jeon, B.J.;Shin, M.C.;Lee, B.G.;Yun, S.M.;Park, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.193-196
    • /
    • 1997
  • This paper presents the Fault Pattern Estimator(FPE) using the neural network for the protection of the T/L. The proposed FPE has two neural network parts of the fault-types classification and the fault-location estimation. It can detect the fault signals more Quickly and accurately. To prove the performance of the FPE, we have tested using a relaying signals obtained from the EMTP simulations.

  • PDF

A new algorithm for power system stability calculations (전력계통안정도 계산앨고리즘의 개선에 관한 연구)

  • 박영문
    • 전기의세계
    • /
    • v.29 no.3
    • /
    • pp.193-200
    • /
    • 1980
  • A new algorithm for power system stability calculations is developed which considers the nonlinear state equations of 8 state variables for each generator dynamics, expollential load models in respect to bus voltages for nonlinear loads, network equations expressed in terms of bus-injected current sources, various kinds of generator and transmission line outages, abrupt changes in loads, and operations of various kinds of portective relaying systems such as distance relaying, reclosing load shedding by under-frequency relays. In the algorithm are included efficient and reliable schemes for solving network equations by means of the Newton-Raphson iterative method and the Optimally-Ordered Triangular Factorization Technique, and simple procedures for determining fault-point negative and zero sequence impedances for unbalanced line faults. An application of the Optimally-Ordered Triangular Factorization Techniques results in remarkable savings in computing time and memory requirements.

  • PDF

A Study on the Implementation of Distance Relaying Techniques using EMTP MODELS (EMTP MODELS를 사용한 거리계전기법 구현에 관한 연구)

  • Lee, Myong-Hee;Choi, Hae-Sul;Seo, Yong-Pil;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.634-636
    • /
    • 1995
  • This paper presents a new distance relay modeling techniques which avoids unnecessary computational procedure. A general-purpose simulation language, called MODELS, has been added to the software ATP(Alternative Transients Program) providing a new option to perform numerical and logical manipulations of variables of an electrical system. This language has been designed to replace the previous option TACS (Transient Analysis of Control Systems) which permits to simulate a control system in conjunction with a large power network. One purpose of this study is to build a structure for modeling of digital distance relays within EMTP MODELS. Contrary to the traditional methods, the new method using MODELS reduce the number of simulation steps in modeling the distance relay.

  • PDF

Simulation of the Distance Relay Using EMTP MODELS

  • J.Y. Heo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.26-32
    • /
    • 2004
  • Digital technology has advanced significantly over the years both in terms of software tools and hardware availability. It is now applied extensively throughout many area of electrical engineering including protective relaying in power systems. Digital relays have numerous advantages over traditional analog relays, such as the ability to accomplish what is difficult or impossible using analog relays. Although non real-time simulators like PSCAD/EMTDC are employed to test the algorithms, such simulations are disadvantaged in that they cannot test the relay dynamically. Hence, real-time simulators like RTDS are used. However, the latter requires large space and is very expensive. This paper uses EMTP MODELS to simulate the power system and the distance relay. The distance relay algorithm is implemented and the distance relay is interfaced with a test power system. The distance relay's performance is then assessed interactively under various fault types, fault distances and fault inception angles. The test results show that we can simulate the distance relay effectively and we can examine the operation of the distance relay very closely including its drawbacks/limitations by using EMTP MODELS. Equally important, this approach facilitates any changes that need to be carried out in order to enhance the Distance Relay under test/examination.

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

A Dynamic Simulation of Distance Relay Using EMTP MODELS (EMTP MODELS를 이용한 거리 계전기 응동 시뮬레이션)

  • 허정용;김철환;여상민
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.1
    • /
    • pp.17-28
    • /
    • 2003
  • Digital technology has advanced very significantly over the years both in terms of software tools and hardware available. It is now applied extensively in many area of electrical engineering including protective relaying in power systems. Digital relays based on digital technology have many advantages over the traditional analog relays. The digital relay is able to do what is difficult or impossible in the analog relays. However, the complex algorithms associated with the digital relays are difficult to test and verify in real time on real power systems. Although non real-time simulators like PSCAD/EMTDC are employed to test the algorithms, such simulations have the disadvantage that they cannot test the relay dynamically. Hence, real-time simulators like RTDS are used, but the latter needs large space and it is very expensive. This paper uses EMTP MODELS to simulate the power system and the distance relay. The distance relay algorithm is constructed and the distance relay is interfaced with a test power system. The distance relays performance is then assessed interactively under various fault types, fault distances and fault inception angles. The test results show that we can simulate the distance relay effectively and we can examine the operation of the distance relay very closely including debugging by using EMTP MODELS.

Analysis of the response of a distance relay for wind farm intertie protection (풍력발전단지 연계선 보호 거리계전기의 응동 특성 분석)

  • Kang, Yong-Cheol;Lee, Hye-Won;Zheng, Tai-Ying;Kang, Hae-Gweon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.484_485
    • /
    • 2009
  • Power output of a wind farm fluctuates throughout a day. This affect a distance relay for wind farm intertie protection because a voltage of a relaying point varies due to fluctuating output of a wind farm. This paper describes the analysis of the response of a distance relay for intertie protection when the power output of a wind farm increases. A series of single phase to ground faults were also simulated and analyzed with PSCAD/EMTDC generated data.

  • PDF

Development of Digital Distance Relay Algorithm Using Fuzzy Inference System on Underground Power Cable Systems (퍼지추론 시스템을 이용한 지중송전계통 보호용 디지털 거리계전 알고리즘 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.502-503
    • /
    • 2006
  • If the fault occurs on the underground Power cable system, the fault current on the sheath has the influence on all sections because it's returned through earth at the directly grounded point and operation point of SVL(Sheath Voltage Limiter) at joint box. Therefore, the earth resistance and the operation of SVL have an effect on the zero-sequence current. Then the impedance between relaying point and fault point is Increased. That causes the overreach of distance relay. For these reasons, the distance relay algorithm for protecting of the underground power cable systems was developed. It effectively advance the errors using ACI(Advanced Computing Intelligence) technique. In this algorithm, the optimization was performed by fuzzy inference system and genetic algorithm.

  • PDF

A New fault Location Algorithm for 765㎸ Untransposed Parallel Transmission Lines (765㎸ 비연가 송전선로에서 고장점 표정 알고리즘)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.168-174
    • /
    • 2004
  • This paper describes a new fault location algorithm based on the voltage equation at the relaying point using 6-phase current for untransposed 765㎸ parallel transmission lines. The proposed method uses the voltage and current collected at only the local end. By means of 3-phase circuit analysis theory to compensate the mutual coupling effects between parallel lines, the fault location is derived. The fault distance is determined by solving the 2nd distance equation based on KVL(Kirchhoff's Voltage Law). Extensive simulation results using EMTP(Electromagnatic Transients Program) have verified that the error of the fault location achieved is up to 4.56(%) in untransposed parallel transmission lines.