• 제목/요약/키워드: Distance relaying

검색결과 94건 처리시간 0.022초

상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘 (A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

진행파 기법을 이용한 새로운 초고속 거리계전 방식 (A New Ultra High Speed Distance Relaying Method Using Travelling Wave Technique)

  • 강상희;박종근
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1203-1210
    • /
    • 1991
  • This paper proposes a new distance relaying method based on fault initiated travelling waves for transmission line protection. The characteristics of this method are ultra high speed and excellent sensitivity. Travelling wave technique which is one of the distance relaying methods uses the discrete cross correlation function for discrimination between internal and external fault is remarkably reduced in case of a close up fault and an inception angle near or equal to zero fault. To cope with this problem, a new fast algorithm which uses backward wave summation method with fixed window is presented. The proposed method has been tested by numerical simulations using the EMTP.

  • PDF

Two-Way Relaying-Based Two-Hop Two-User Multiple-Input Multiple-Output System

  • Cho, Young Seek;Choi, Seyeong
    • Journal of information and communication convergence engineering
    • /
    • 제12권2호
    • /
    • pp.67-74
    • /
    • 2014
  • In multi-hop communication systems, two-way relaying is one of the solutions to mitigate the spectral efficiency loss caused by a half-duplex transmission. In this paper, a simple two-way relaying scheme is proposed for two-hop two-user multiple input multiple output (MIMO) systems. In the proposed system, a base station and a relay station (RS), both equipped with two antennas, form a point-to-point MIMO channel, while the RS and two single-antenna mobile users form a point-to-multipoint multiuser (MU)-MIMO channel. Numerical examples show that the proposed system achieves a significant sum rate gain as compared to a one-way relaying system as the distance between a relay and the two users decreases. We also show that although we can expand the proposed scheme to more than two users, its performance gain as compared to that of one-way relaying decreases with an increase in the number of users.

DSP를 이용한 학습용 계전기 보드 개발 (Development of Learning Board for the Digital Relay Using DSP)

  • 안용진;최영우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.187-189
    • /
    • 2002
  • A relaying board is developed for the study of digital relay, which is based on Digital Signal Processor(DSP). The present development is capable of understanding and application for digital relay hardware. To support the design of relaying hardware, first A/D convertor MMI and serial port for communication are embedded, and next a booting cables of three types are supplied. More particularly the relaying board that is convinient to test digital relaying algorithm. This paper concludes by implementing the distance relaying algorithm into a relaying board, the hardware test results show practically high performance.

  • PDF

고장저항의 영향을 최소화한 순환형 거리계전 알고리즘 (A Recursive Distance Relaying Algorithm Immune to Fault Resistance)

  • 안용진;강상희;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.259-261
    • /
    • 2001
  • An accurate digital distance relaying algorithm which is immune to the combined reactance effect of the fault resistance and the load current is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the apparent impedance, this algorithm uses iteratively the angle of an impedance deviation vector improved step by step. The impedance correction algorithm for ground faults uses a current distribution factor to compensate mutual coupling effect.

  • PDF

UPFC가 연계 된 강진-장흥 송전선로 보호용 거리계전기의 동작특성에 관한 연구 (A Study on Operation Zone of Adaptive Distance Relay on Transmission Line Connected UPFC Between Kangjin and Jangheung)

  • 이승혁;정창호;김진오;정현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.305-307
    • /
    • 2003
  • This paper presents an apparent impedance calculation procedure for distance relaying of transmission line involving FACTS (Flexible AC Transmission System) devices, particularly the UPFC (Unified Power Flow Controller), between Kangjin and Jangheung in Korea. With the changes of UPFC's parameters, the measurement and protective range (trip boundaries) of the adaptive distance relay can also be changed. So, it is the most important part in the field of system protection to analyze the operating characteristic of relaying system. The presence of UPFC significantly affects the trip boundaries which are also adversely affected by fault resistance combined with remote end infeed. This paper presents the apparent impedance calculations and the distance relay setting characteristics for faults involving the UPFC in the KEPCO system.

  • PDF

에이전트 환경에서의 1선지락 거리계전 알고리즘 (Agent-Based Distance Relaying Algorithm for Phase-to-Ground Faults)

  • 현승호;진보건;이승재
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1885-1891
    • /
    • 2007
  • This paper presents a distance relaying algorithm for phase-to-ground faults in transmission lines under Multi-Agent protection environment. In normal condition, a distance relay agent stores the latest states, e.g., voltage of source side, voltage of the opposite side and the loading conditions, etc., through communication between the agents. Once a fault occurs, the relay calculates the fault location using the knowledge about the states just before the fault happens. This stand-alone operation is to improve reliability under the fault condition at which the accuracy or time required for communication may not be guaranteed. The mathematical expression of fault location is derived through loop analysis, before hand, in the manner that both fault current from the opposite end and fault resistance are included implicitly so that their effects are minimized. The suggested algorithm is applied to a typical transmission system with two power sources on both ends to show its effectiveness.

주파수 특성을 고려한 송전선 보호용 적분근사거리계전 알고리즘의 최적 적분 계수 결정 (Optimal Solution of integral Coefficients in Distance Relaying Algorithm for T/L Protection considering Frequency Characteristics)

  • 조경래;홍준희;정병태;조정현;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.42-44
    • /
    • 1994
  • This paper presents the method of estimating integral coefficients of new distance relaying algorithm for transmission line protection. The proposed method is based on the differential equation calculates impedance value by approximation of integral term of integro-differential equation which relate voltage with current. As a result, we can determine the integral coefficients in least square error sense in frequency domain and we take into consideration the analog filter characteristics and frequency domain characteristics of the system to be protected. The simulation results showed that these coefficients can be successfully used to obtain impedance value in distance relay.

  • PDF

리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘 (A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems)

  • 안용진;강상희;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF

Fault ride-through 요구를 고려한 풍력발전단지 연계선 보호 거리계전 알고리즘 (Distance Relaying Algorithm for Intertie Protection of a Wind Farm Considering the Fault Ride-through Requirement)

  • 강용철;강해권;정태영;김연희;이영귀
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1053-1058
    • /
    • 2010
  • A large modern wind farm should satisfy the requirements for a grid and accomplish the optimization of the wind farm system. The wind farm intertie protection system should consider a Fault Ride-Through (FRT) requirement for more reliable protection. The wind farm should keep connected to the grid in the case of a grid fault whilst it should be isolated for an intertie fault. This paper proposes a distance relaying algorithm suitable for wind farm intertie protection considering the FRT requirement. The proposed algorithm estimates the impedance based on a differential equation method because the frequency of the voltage and current deviates the nominal frequency. The algorithm extends the reach of Zone 1 up to 100 % of the length of the intertie to implement the FRT requirement. To discriminate an intertie fault from a grid fault, the algorithm uses a voltage blocking scheme because the magnitude of the voltage at the relaying point for an intertie fault becomes less than that for a grid fault. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various fault conditions. The algorithm can discriminate successfully the intertie fault from grid fault and thus helps to implement the FRT requirement of a wind farm.