• Title/Summary/Keyword: Distance parameters

Search Result 1,981, Processing Time 0.033 seconds

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

The difference in the location of the malar summit between genders in Southeast Asians with appropriate references

  • Jirawatnotai, Supasid;Sriswadpong, Papat
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.78-84
    • /
    • 2021
  • Background: Facial feminization surgery and malarplasty require information concerning facial features in the malar area. Such information varies as a function of sex and race. The objectives of this study aimed to quantitatively evaluate the location of malar prominence across sexes in the Southeast Asian population, and identify sex-specific differences in malar prominence using a combination of two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) CT. Methods: The location of malar prominence was evaluated in 101 Thai adults, consisting of 52 men and 49 women. This study used both 2D CT and 3D CT to achieve greater accuracy, in which 2D CT was used to measure malar distance, malar summit width, facial width, and malar summitto-facial width ratio whereas 3D CT was used to evaluate the positional relationship between the zygomatic summit and four reference points of the zygoma. Results: The malar summit was positioned more laterally in males (p< 0.01) and was more projected in females (p= 0.01). The other 2D-parameters were wider in males. The ratio between the malar summit width and facial width showed similar results for both sexes. The vertical dimension did not show any statistically significant differences; however, a higher summit position was observed in males. Conclusion: The zygomatic summit is positioned more laterally in males and is more projected in females. However, the ratio was similar, which indicates that the male cranium is larger in size. Based on the results in this study, when facial feminization surgery or malarplasty is performed on a Southeast Asian patient, the malar bone should be reduced horizontally and moved forward for better outcomes.

Comparison of the effects of rapid maxillary expansion and alternate rapid maxillary expansion and constriction protocols followed by facemask therapy

  • Ozbilen, Elvan Onem;Yilmaz, Hanife Nuray;Kucukkeles, Nazan
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.49-58
    • /
    • 2019
  • Objective: The aim of this retrospective study was to evaluate and compare the changes in the pharyngeal airway (PA), maxillary sinus volume, and skeletal parameters after rapid maxillary expansion (RME) and alternate rapid maxillary expansion and constriction (Alt-RAMEC) followed by facemask (FM) therapy. Methods: The records of 40 patients with skeletal Class III malocclusion due to maxillary retrognathism were collected, and the patients were assigned into two groups. The first group comprised 8 male and 12 female patients (mean age, $10.0{\pm}1.1years$) treated using RME/FM for an average of 10 months. The second group comprised 10 male and 10 female patients (mean age, $9.64{\pm}1.3years$) treated using Alt-RAMEC/FM for an average of 12 months. Cone-beam computed tomography images acquired before (T0) and after treatment (T1) were evaluated. Results: Regarding the skeletal effects, significant differences between the groups were the increase in ANS-HRP (perpendicular distance of ANS to the horizontal reference plane, 0.99 mm, p <0.05) in the Alt-RAMEC/FM group and the decrease in PP-SN (palatal plane to Sella-Nasion plane, $0.93^{\circ}$, p < 0.05) in the RME/FM group. Maxillary sinus volumes increased significantly in both the groups, and the increase was statistically significantly higher in the Alt-RAMEC/FM group. Although no significant intergroup differences were observed in PA volumes, both lower ($1,011.19mm^3$) and total ($1,601.21mm^3$), PA volume increased significantly in the Alt-RAMEC/FM group. Conclusions: The different expansion devices and protocols used with FM therapy do not seem to affect the forward movement of the maxilla and PA volumes. In contrast, the increase in maxillary sinus volume was greater in the Alt-RAMEC/FM protocol.

Small- and large-scale analysis of bearing capacity and load-settlement behavior of rock-soil slopes reinforced with geogrid-box method

  • Moradi, Gholam;Abdolmaleki, Arvin;Soltani, Parham
    • Geomechanics and Engineering
    • /
    • v.18 no.3
    • /
    • pp.315-328
    • /
    • 2019
  • This paper presents an investigation on bearing capacity, load-settlement behavior and safety factor of rock-soil slopes reinforced using geogrid-box method (GBM). To this end, small-scale laboratory studies were carried out to study the load-settlement response of a circular footing resting on unreinforced and reinforced rock-soil slopes. Several parameters including unit weight of rock-soil materials (loose- and dense-packing modes), slope height, location of footing relative to the slope crest, and geogrid tensile strength were studied. A series of finite element analysis were conducted using ABAQUS software to predict the bearing capacity behavior of slopes. Limit equilibrium and finite element analysis were also performed using commercially available software SLIDE and ABAQUS, respectively to calculate the safety factor. It was found that stabilization of rock-soil slopes using GBM significantly improves the bearing capacity and settlement behavior of slopes. It was established that, the displacement contours in the dense-packing mode distribute in a broader and deeper area as compared with the loose-packing mode, which results in higher ultimate bearing load. Moreover, it was found that in the loose-packing mode an increase in the vertical pressure load is accompanied with an increase in the soil settlement, while in the dense-packing mode the load-settlement curves show a pronounced peak. Comparison of bearing capacity ratios for the dense- and loose-packing modes demonstrated that the maximum benefit of GBM is achieved for rock-soil slopes in loose-packing mode. It was also found that by increasing the slope height, both the initial stiffness and the bearing load decreases. The results indicated a significant increase in the ultimate bearing load as the distance of the footing to the slope crest increases. For all the cases, a good agreement between the laboratory and numerical results was observed.

STUDY OF ULTRALUMINOUS X-RAY SOURCES IN SOME NEARBY GALAXIES

  • Singha, Akram Chandrajit;Devi, A Senorita
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • We present the results of the spectral and temporal analysis of eight X-ray point sources in five nearby (distance < 20 Mpc) galaxies observed with Chandra. For spectral analysis, an absorbed powerlaw and an absorbed diskblackbody were used as empirical models. Six sources were found to be equally fitted by both the models while two sources were better fitted by the powerlaw model. Based on model parameters, we estimate the X-ray luminosity of these sources in the energy range 0.3 - 10.0 keV, to be of the order of ${\sim}10^{39}ergs\;s^{-1}$ except for one source (X-8) with $L_X>10^{40}ergs\;s^{-1}$. Five of these maybe classified as Ultraluminous X-ray sources (ULXs) with powerlaw photon index within the range, ${\Gamma}{\sim}1.63-2.63$ while the inner disk temperature, kT ~ 0.68 - 1.93 keV, when fitted with the disk blackbody model. The black hole masses harboured by the X-ray point sources were estimated using the disk blackbody model to be in the stellar mass range, however, the black hole mass of one source (X-6) lies within the range $68.37M_{\odot}{\leq}M_{BH}{\leq}176.32M_{\odot}$, which at the upper limit comes under the Intermediate mass black hole range. But if the emission is considered to be beamed by a factor ~ 5, the black hole mass reduces to ${\sim}75M_{\odot}$. The timing analysis of these sources does not show the presence of any short term variations in the kiloseconds timescales.

Determination of Ship Collision Avoidance Path using Deep Deterministic Policy Gradient Algorithm (심층 결정론적 정책 경사법을 이용한 선박 충돌 회피 경로 결정)

  • Kim, Dong-Ham;Lee, Sung-Uk;Nam, Jong-Ho;Furukawa, Yoshitaka
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.1
    • /
    • pp.58-65
    • /
    • 2019
  • The stability, reliability and efficiency of a smart ship are important issues as the interest in an autonomous ship has recently been high. An automatic collision avoidance system is an essential function of an autonomous ship. This system detects the possibility of collision and automatically takes avoidance actions in consideration of economy and safety. In order to construct an automatic collision avoidance system using reinforcement learning, in this work, the sequential decision problem of ship collision is mathematically formulated through a Markov Decision Process (MDP). A reinforcement learning environment is constructed based on the ship maneuvering equations, and then the three key components (state, action, and reward) of MDP are defined. The state uses parameters of the relationship between own-ship and target-ship, the action is the vertical distance away from the target course, and the reward is defined as a function considering safety and economics. In order to solve the sequential decision problem, the Deep Deterministic Policy Gradient (DDPG) algorithm which can express continuous action space and search an optimal action policy is utilized. The collision avoidance system is then tested assuming the $90^{\circ}$intersection encounter situation and yields a satisfactory result.

A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

  • Na, Eui-Ri;Aljawad, Hussein;Lee, Kyung-Min;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.41-48
    • /
    • 2019
  • Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experienceor projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.

Failure analysis of capacitor for sub-module in HVDC (HVDC 서브모듈용 커패시터의 고장 분석)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.941-947
    • /
    • 2018
  • In general, capacitors have a large influence on the life of the system due to frequent charging and discharging. In this paper, we analyze the cause of the core failure of high voltage, high current HVDC sub-module film capacitor and analyze the precautions of the capacitor design and manufacturing process. First, the cause of the fault, the failure mode, and the effect are analyzed through the FMEA of the capacitor. To quantitatively evaluate the causes and effects of faults that have the greatest effect on the failure of a capacitor, a fault tree for the capacitor is presented and the failure rate is analyzed according to the design parameters and the driving conditions. It is verified that the main cause of capacitor failure is the capacitance change, and it is necessary to minimize the temperature rise, corona occurrence, electrode expansion, and insulation distance decrease during capacitor design and manufacturing process in order to reduce the failure rate of the capacitor.

Design of Broadband Microstrip Antenna for 2.5GHz with Inverted Parasite Patch and the Proximity Stub (근접 스터브와 뒤집힌 기생 패치를 이용한 2.5GHz용 광대역 마이크로스트립 안테나의 설계)

  • Cho, Ki-Ryang;Kim, Dae-Ik;Kim, Gun-Kyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.467-474
    • /
    • 2019
  • In this paper, we studied a method for a broadband stacked patch antenna structure which is widely used for bandwidth improvement. The characteristics according to the distance between the two patches were analyzed and the impedance matching was optimized by connecting parallel open stubs to the main patch feed line. The shunt matching stub is inserted underneath the parasitic patch and so it does not require additional space, which enables the proposed antenna structure to be advantageous in miniaturizing antenna. The effects of the various parameters on the antenna performance are examined, and we introduced the design procedure for the proposed antenna to operate in the frequency range of 2.3~2.7GHz. Experimental results show that the bandwidth of the proposed antenna is about 480MHz with 2.27~2.75GHz bandwidth. And the antenna gain was 5.8dBi at 2.3GHz and 7.8dBi at 2.6GHz within the bandwidth.

Design of a Compact Broadband Stacked Microstrip Patch Antenna (광대역 적층 마이크로스트립 패치 안테나의 소형화 설계)

  • Kim, GunKyun;Rhee, Seung-Yeop;Yeo, Junho;Lee, Jong-Ig;Kim, Ohn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.72-73
    • /
    • 2016
  • In this paper, we studied a method for miniaturizing a broadband stacked patch antenna structure which is widely used for bandwidth improvement. Main patch is a rectangular microstrip patch antenna fed by a 50-ohm microstrip line, and a parasitic patch is laid above the main patch. The size of the main patch is designed to be resonated near the center frequency of the desired frequency band. Then parasitic patch longer than main patch is placed above the main patch. The distance between two patches might be adjusted so as to achieve impedance matching using a shunt open stub. The shunt matching stub is inserted underneath the parasitic patch and so it does not require additional space, which enables the proposed antenna structure to be advantageous in miniaturizing antenna. The effects of the various parameters on the antenna performance are examined, and we introduced the design procedure for the proposed antenna to operate in the frequency range of 2.3-2.7 GHz.

  • PDF