• Title/Summary/Keyword: Distance measurement

Search Result 2,360, Processing Time 0.032 seconds

Development of Automated Guidance Tracking Sensor System Based on Laser Distance Sensors

  • Kim, Joon-Yong;Kim, Hak-Jin;Shim, Sung-Bo;Park, Soo-Hyun;Kim, Jung-Hun;Kim, Young-Joo
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.319-327
    • /
    • 2016
  • Purpose: Automated guidance systems (AGSs) for mobile farm machinery have several advantages over manual operation in the crop production industry. Many researchers and companies have tried to develop such a system. However, it is not easy to evaluate the performance of an AGS because there is no established device used to evaluate it that complies with the ISO 12188 standard. The objective of this study was to develop a tracking sensor system using five laser distance measurement sensors. Methods: One sensor-for long-range distance measurement-was used to measure travel distance and velocity. The other four sensors-for mid-range distance measurement-were used to measure lateral deviation. Stationary, manual driving, and A-B line tests were conducted, and the results were compared with the real-time kinematic differential global positioning system (RTK-DGPS) signal used by the AGS. Results: For the stationary test, the average error of the tracking sensor system was 1.99 mm, and the average error of the RTK-DGPS was 15.19 mm. For the two types of driving tests, the data trends were similar. A comparison of the changes in lateral deviation showed that the data stability of the developed tracking system was better. Conclusions: Although the tracking system was not capable of measuring long travel distances under strong sunlight illumination because of the long-range sensor's limitations, this dilemma could be overcome using a higher-performance sensor.

An Efficient Facial Expression Recognition by Measuring Histogram Distance Based on Preprocessing (전처리 기반 히스토그램 거리측정에 의한 효율적인 표정인식)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.5
    • /
    • pp.667-673
    • /
    • 2009
  • This paper presents an efficient facial expression recognition method by measuring the histogram distance based on preprocessing. The preprocessing that uses both centroid shift and histogram equalization is applied to improve the recognition performance, The distance measurement is also applied to estimate the similarity between the facial expressions. The centroid shift based on the first moment balance technique is applied not only to obtain the robust recognition with respect to position or size variations but also to reduce the distance measurement load by excluding the background in the recognition. Histogram equalization is used for robustly recognizing the poor contrast of the images due to light intensity. The proposed method has been applied for recognizing 72 facial expression images(4 persons * 18 scenes) of 320*243 pixels. Three distances such as city-block, Euclidean, and ordinal are used as a similarity measure between histograms. The experimental results show that the proposed method has superior recognition performances compared with the method without preprocessing. The ordinal distance shows superior recognition performances over city-block and Euclidean distances, respectively.

Depth estimation by using a double conic projection (이중원뿔 투영을 이용한 거리의 추정)

  • 김완수;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1411-1414
    • /
    • 1997
  • It is essential to obtain a distane informaion in order to completely execute assembly tasks such as a grasping and an insertion. In this paper, we propose a method estimating a measurement distance from a sensor to an object through using the omni-directional image sensing system for assembly(OISSA) and show its features and feasibility by a computer simulation. The method, utilizing a forwarded motion stereo technique, is simple to search the corresponding points and possible to immediatiely obtain a three-dimensional 2.pi.-shape information.

  • PDF

Investigation of Distance Measurement Performance Using Waveform Clouds-Based Terrestrial Laser Scanner (Waveform 방식의 지상라이다 거리측정 성능 실험)

  • Lee, In-Su;Kim, Hyung-Moo;Cha, Deuk-Gi;Lee, Dong-Rak
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.45-47
    • /
    • 2010
  • Terrestrial Laser Scanner is widely useful in the cultural heritage documentation, acquisition of three-dimensional spatial information in the field of civil engineering and construction, and the safety monitoring for the inaccessible sites such as a few bridges and landslides. This study deals with the investigation of distance measurement and the performances assesment with waveform clouds-based(TLS).

  • PDF

Study on Golf Range Finder by using Biprism Theory of Keratometer (케라토미터의 바이프리즘 원리를 이용한 골프거리측정기에 관한 연구)

  • Cha, Jung-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.495-501
    • /
    • 2013
  • Purpose: This study was to develop golf range finder which could measure exact distance from golfer to flag by using telescope and biprism. Methods: Golf range finder was made that included telescope and biprism which could move in the telescope, and an accuracy of the range finder was analyzed in distance range 20~200 m. Results: An equation was made for measuring distance which was related at position of biprism, and we could measure distance successfully by using developed golf range finder. Biprism of 2 ${\Delta}$ was useful to measure in short distance but it had bad accuracy in long distance, and 0.5 ${\Delta}$ was more useful in long distance. Image got worse when the biprism approch to focal point of objective lens for measurement in long distance, so we developed multi-layer biprism to prevent the weak point. Conclusions: Image stabilization by biprism for measuring distance was confirmed. Even if hand was moving, the distance could be measured well by using biprism, and we could find that the induced equation for distance measurement was useful. We found that multi-layer biprism, which is was new developed, was more useful than general biprism when the biprism approched to focal point of objective lens for measurement in long distance.

Visual Measurement of Pile Movement for the Foundation Work using a High-Speed Line-Scan

  • Lim, Mee-Seub;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1802-1807
    • /
    • 2004
  • When a construction company builds a high structure, many piles should be driven into the ground by a hammer whose weight is 7,000 Kg in order to make the ground under the structure safe and strong. So, it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously

  • PDF

A Study on the Thickness Measurement of Thin Film by Ultrasonic Wave (초음파(超音波)를 이용(利用)한 박막(薄膜)두께 측정(測定)에 관(關)한 연구(硏究))

  • Han, Eung-Kyo;Lee, Jae-Joon;Kim, Jae-Yeol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.27-34
    • /
    • 1988
  • Recently, it is gradually raised necessity that thickness of thin film is measured accurately and managed in industrial circles and medical world. In this study, regarding to the thickness of film which is in opaque object and is beyond distance resolution capacity, thickness measurement was done by MEM-cepstrum analysis of received ultrasonic wave. In measurement results, film thickness which is beyond distance resolution capacity was measured accurately. And within thickness range that don't exist interference, thickness measurement by MEM-ceptrum analysis was impossible.

  • PDF

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.