• Title/Summary/Keyword: Distance Variation

Search Result 1,186, Processing Time 0.03 seconds

Local Structure Study of Ni in Ni-Zn Alloy Coating on Steel by X-ray Absorption Spectroscopy (X선 흡수 분광법을 이용한 Ni-Zn 도금 강판에서의 Ni의 국부 구조에 관한 연구)

  • Lee, Do-Hyung
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.202-205
    • /
    • 1998
  • X-ray absorption fine structure spectroscopic studies at the Ni K-edge have been performed for the Ni-Zn alloy coating layer on steel. The Ni-Zn interatomic distances and Debye-Waller factors were determined by fitting the experimental data with the theoretical spectra in the temperature range of 80 to 300K. The average Ni-Zn interatomic distance was found to be $2.557{\AA}$ and the variation of the Ni-Zn interatomic distance with temperature in this range was insignificant. From the comparison of the Ni-Zn interatomic distance with the nearest neighbor distance of pure Zn lattice it has been suggested that there is an apparent contraction around Ni atom.

  • PDF

Propagation Characteristics and Effects of Road Traffic Noise (도로교통소음의 전파특성 및 영향)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Kang, Dae-Joon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.311-315
    • /
    • 2008
  • This study was performed to investigate propagation characteristics and effects of road traffic noise generated from vehicles. Noise levels of expressway and general road were measured at four points in a straight line based on distance from the road, and analyzed. The average noise level of expressway was 78.9 dBA at 5 m, 76.4 dBA at 10 m, 72.0 dBA at 20 m, 69.0 dBA at 30 m. That of general road was lower about $3.1{\sim}3.5\;dBA$ than that of expressway. There was no significant difference in distance attenuation between expressway noise and general road noise. The farer the distance from source is, the more the attenuation is. The influence range of noise is assessed by noise environmental standards or road noise limits. Noise levels of the time zone were measured at a boundary line of apartment to grasp noise variation by time. The time zone of lowest noises was $3{\sim}4$ a.m. and that of highest noise was $8{\sim}10$ a.m. Data recorded on tapes were analyzed to understand the characteristics of frequency because these characteristics are important factors to plan the noise reduction measures, namely path measures.

Monte Carlo Investigation of Spatially Adaptable Magnetic Behavior in Stretchable Uniaxial Ferromagnetic Monolayer Film

  • Laosiritaworn, Yongyut;Laosiritaworn, Wimalin
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.11-20
    • /
    • 2015
  • In this work, Monte Carlo simulation was employed to model the stretchable Ising monolayer film to investigate the effect of the spatial distance variation among magnetic atoms on magnetic behavior of the film. The exchange interaction was considered as functions of initial interatomic distance and the stretched distance (or the strain). Following Bethe-Slater picture, the magnetic exchange interaction took the Lennard-Jones potential-like function. Monte Carlo simulations via the Wolff and Metropolis algorithms were used to update the spin systems, where equilibrium and dynamic magnetic profiles were collected. From the results, the strain was found to have strong influences on magnetic behavior, especially the critical behavior. Specifically, the phase transition point was found to either increase or decrease depending on how the exchange interaction shifts (i.e. towards or away from the maximum value). In addition, empirical functions which predict how the critical temperatures scale with initial interatomic distance and the strain were proposed, which provides qualitatively view how to fine tune the magnetic critical point in monolayer film using the substrate modification induced strain.

Experimental study on effect of underground excavation distance on the behavior of retaining wall

  • Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • v.17 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • The changes in earth pressure and ground settlement due to underground excavation near an existing retaining wall were studied experimentally according to the separation distance between the underground excavation and the retaining wall. In addition, this study attempted to experimentally prove that the arching phenomenon occurred during the construction of the underground space. A model tank having 120 cm in length, 160 cm in height, and 40 cm in width was manufactured to simulate underground excavation through the use of five separated base wall bodies. The variation of earth pressure on the retaining wall was measured according to the underground excavation phase through the use of 10 separated right wall bodies. The results showed that the earth pressure on the retaining wall was changed by the lowering of the first base bottom wall; however, the earth pressure was not changed significantly by the lowering of the third base bottom wall, since the third base wall had sufficient separation distance from the retaining wall. Lowering of the first base wall induced a decrease in the earth pressure in the lower part of the retaining wall; in contrast, lowering of the first base wall induced an increase in the earth pressure in the middle part of the retaining wall, proving the arching effect experimentally. It is necessary to consider the changes in earth pressure on the retaining wall in designing earth retaining structures for sections where the arching effect occurs.

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

A Multiple Planting in a Hole for Producing an Aromatic Tobacco Variety, Sohyang(Nicotiana tabacum L.) (향끽미품종담배의 식혈간 거리와 식혈당 주수가 수량 및 품질에 미치는 영향)

  • 정기택;변주섭
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 1981
  • This study was carried out to investigate the influence of distance of planting holes (51, 45, and 40 cm) and number of plants per a hole(4, 5, 6 plants) on agronomic characteristics, yield, and quality of an aromatic tobacco, Sohyang. The results are as follows: 1. Relative light intensity increased by widening the distance of holes. 2. Leaf area per a plant or per a leaf, and leaf length and width increased by widening the distance of holes and decreased by increasing the number of plants per a hole. But L. A. 1. increased by increasing the number of plants per a hole. Leaf shape index (Leaf length/Leaf width) showed little differences among treatments. 3. Dry weight of leaf, root, and stem per a plant decreased by increasing the number of plants per a hole. 4. Total nitrogen decreased by increasing number of plants per a hole and in the case of narrow distance of holes, but nicotine, reducing sugar, ether-extract and ash showed little differences. 5. Yield per 10a decreased by widening the distance of holes. 6. Quality(price per kg) was improved by increasing the number of plants per a hole at the Plot of 51m distance of holes. But there was no variation at the Plot of 45cm. And quality was decreased at the plot of 40cm distance of holes by increasing the number of Plants per a hole. 7. Price per 10a was highest in the plot of which plant spacing was $90\times$40cm and the number of plants per a hole was 4 (11112 plant/10a).

  • PDF

An Experimental Study on the Characteristics of Twin Spray Ejected from Two Swirl Spray Nozzles (두개의 와류분무 노즐로부터 분사되는 이중분무의 분무특성에 관한 실험적 연구)

  • 김인구;이상룡
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.359-372
    • /
    • 1988
  • Characteristics of twin spray ejected from two swirl spray nozzles were studied experimentally. By using a patternator for measuring volumetric flux of drop flow at various locations inside the spray, variation of the twin spray pattern along the axial direction was studied with changing the injection pressure and the distance between the nozzles. The general findings from the experiments are as follows: (i) as axial distance from the nozzles increases, the spray pattern in x-z plane which contains both nozzles changes significantly. On the other hand the spray pattern in y-z plane which passes the midpoint between two nozzles remains almost unchanged at outer region as axial distance and injection pressure vary; (ii) at the downstream of the twin spray with spray interaction, the maximum volumetric flux in y-z plane (q$_{max}$)$_{y}$, has tendency to become larger than that of x-z plane (q$_{max}$)$_{x}$, due to a characteristic(hollow cone shape) of the constituting swirl sprays, and this trend is pronounced at higher injection pressure since the cross-section of each single spray remains hollow at the longer axial distance from each nozzle with higher injection pressure; (iii) at a certain axial distance from the nozzles, the cross-sectional shape of the boundary of the twin spray tends to be circular similar to that of the single spray with twice the flow-rate, and that distance is not proportional to the distance between two nozzles; (iv) though there are some collisions between droplets from each nozzles of twin spray, in present experimental range, the flow pattern of gas including the entrainment effect plays the key role in spray interaction.n.ion.n.

Effect of Distance Phoria on Stereoacuity (원거리 사위도가 입체시에 미치는 영향)

  • Chun, Young-Yun;Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • Purpose: In this study we measured the mean value of the distance stereoacutiy for adult subjects and evaluated the variation of the distance stereoacuity according to correction of phoria using the Pola Test E-II of Carl Zeiss. Methods: We investigated the distance stereoacuity for 50 adults (male: 29, female: 21) ranging in age from 19 to 46 years using D6 Circle chart and D8 Line chart in the Pola Test E-II. Results: The mean values of the distance stereoacuity measured on the D6 Circle test and D8 Line test were 159.6 and 149.4 seconds of arc respectively. The mean variations of the distance stereoacuity according to correction of phoria in D6 Circle test were increased 43.2 seconds of arc in exophoria and 51 seconds of arc in esophoria, and those in D8 Line test were increased 42 seconds of arc in exophoria and 70.2 seconds of arc in esophoria. Conclusions: We knew from these results that the distance stereoacuity after prescription of phoria improved more esophoria than exophoria.

  • PDF

An Improved Face Detection Method Using a Hybrid of Hausdorff and LBP Distance (Hausdorff와 LBP 거리의 융합을 이용한 개선된 얼굴검출)

  • Park, Seong-Chun;Koo, Ja-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.67-73
    • /
    • 2010
  • In this paper, a new face detection method that is more accurate than the conventional methods is proposed. This method utilizes a hybrid of Hausdorff distance based on the geometric similarity between the two sets of points and the LBP distance based on the distribution of local micro texture of an image. The parameters for normalization and the optimal blending factor of the two different metrics were calculated from training sample images. Popularly used face database was used to show that the proposed method is more effective and robust to the variation of the pose, illumination, and back ground than the methods based on the Hausdorff distance or LBP distance. In the particular case, the average error distance between the detected and the true face location was reduced to 47.9% of the result of LBP method, and 22.8% of the result of Hausdorff method.

Analysis Of Spatial Impact With Seoul Subway Line 7 Construction (지하철 건설에 따른 공간적 영향 분석 - 서울 지하철 7호선의 아파트가격에 미친 영향을 중심으로 -)

  • 여홍구;최창식
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.2
    • /
    • pp.155-162
    • /
    • 2004
  • In order to account for a price variation of apartment that places near a newly constructed subway station, a spatial hedonic model was developed to examine spacial characteristics that affect a purchasing price of an apartment using a White Estimator. In particular, the paper aims to examine various effects of subway 7 construction on an apartment price in Seoul Metropolitan Area. As explanatory variables, an apartment size, distance to a closest subway station, distance to the Central Business District (CBD) of Seoul, the number of years after building, and a lagged variable of the apartment purchasing price were used. The lagged variable plays a role of representing a spatial weighted average of previous prices of other apartments that locate within 3 km from the apartment. For a precise study, an entire sample was divided into two sets, southern area and southwestern area of Seoul, and two different spatial hedonic models were estimated. Not only before and after analysis, but also with and without analysis were conducted to compare with different effects of the spatial characteristics of two areas. The results show that before the construction of the subway 7, the prices of the apartments in the southern area were more sensitive to the apartment size, the distance to a closest subway station, the distance to the CBD, and the prices of the other apartments locating within 3km rather than those in the southwestern area. After the construction, on contrast, it is found that the apartment purchasing prices in the southwestern area are more sensitive than those in the southern area due to people's expectation regarding a new development around the subway station. In addition, the prices of the apartments locating closely with a transfer station are more likely to go up by increase in the apartment size, the distance to the station, and the prices of the other apartments within 3 km. Compared with the negative effects of the distance to the station on the prices in the other models, the positive effect of the distance to the transfer station might be caused by the characteristics of commercial area in which people are not likely to live.