• 제목/요약/키워드: Distance Variation

Search Result 1,183, Processing Time 0.036 seconds

Oscillatory Features of Supersonic Impinging Jet Flows; Effects of the Nozzle Pressure Ratio and Nozzle Plate Distance (노즐 압력비와 충돌면까지의 거리 변화에 따른 초음속 충돌 제트 유동의 진동 특성)

  • Kim S. I.;Park S. O.;Lee K. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.154-159
    • /
    • 2004
  • Numerical simulations of supersonic impinging jet flows are carried out using the axisymmetric Navier-Stokes code. This paper focuses on the oscillatory flow features associated with the variation of the nozzle pressure ratio and nozzle-to-plate distance. Frequencies of the surface pressure oscillation from computational results are in accord with the measured impinging tones for various cases of nozzle-to-plate distance. The variation of this frequency with distance show a staging behavior. Computed results for the case of nozzle pressure ratio variation for a fixed nozzle-to-plate distance also demonstrate a staging behavior. These two seemingly different staging behaviors are found to obey the same frequency-distance characteristics when the frequency and the distance are normalized by using the length of the shock cell.

  • PDF

The Seasonal Variation of Free Chlorine Residuals by Water Supply Distance in Daegu (대구 지역의 계절 변화에 따른 급수관내 잔류염소 농도 거동)

  • Lee, Tae-Gwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.363-369
    • /
    • 2005
  • This paper presents the integrated technique of water quality analysis and Geographic Information System(GIS) for assessing the variation of free chlorine residuals by water temperature and supply distance in Sangri water supply system in Daegu. GIS was utilized for mapping projectmap, extraction of a pipeline route, and supply distance. Free chlorine residual is analyzed every month for appraising the seasonal variation. As a result, free chlorine residuals are affected both water temperature and water supply distance, and it becomes worse as water temperature and water supply distance is increased. To maintain 0.4mg/l of free chlorine residual, initial dose concentration should be over 1.85mg/l in summer.

A Study on the Compensating System for the Acoustic Characteristics Caused by the Variation of Distance from Sound Source to Microphone (음원과 마이크로폰 사이의 거리변화에 의한 음향 특성 보정에 관한 연구)

  • Jeoung, Byung-Chul;Choe, Yoon-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.197-204
    • /
    • 2012
  • In this thesis, studied the method to minimize the changes in frequency response and level due to the variation of the distance from the source to the microphone. selecting three microphones (omni directional, cardioid, super cardioid) which are being used generally, frequency responses were measured in accordance with the distance changes. Gotten the difference from the reference as the result of measurement, changed responses for each frequency range were compensated in comparison of the original human vocal source. In low frequency range, the low frequency boost caused by the proximity effect and decrease in accordance with the distance were compensated. The variation in mid-frequency range is comparatively small, however since the mid-range is the most important part of the human vocal signal, were compensated the mid-frequency range in comparison of the reference. The human vocal signal variation in high frequency range is extremely small and the high frequency is compensated close to the original source without difficulty. Understanding the microphone characteristics and compensations, this study showed that the response can be maintain among the change of the distance from the source to the microphone.

Analysis of High Dose Rate Intracavitary Radiotherapy(HDR-ICR) Treatment Planning for Uterine Cervical Cancer (자궁경부암의 고선량율 강내치료 선량계획 분석)

  • Chai, Gyu-Young
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.387-392
    • /
    • 1994
  • Purpose : This study was done to confirm the reference point variation according to variation in applicator configuration in each fractioation of HDR ICR. Materials and Methods : We analyzed the treatment planning of HDRICR for 33 uterine cervical cancer patients treated in department of therapeutic radiology from January 1992 to February 1992. Analysis was done with respect to three view points-Interfractionation A point variation, interfractionation bladder and rectum dose ratio variation, interfractionation treatment volume variation. Interfractionation A point variation was defined as difference between maximum and minimum distance from fixed rectal point to A point in each patient. Interfractionation bladder and rectum dose ratio variation was defined as difference between maximum and minimum dose ratio of bladder or rectum to A point dose in each patient, Interfractionation treatment volume variation was defined as difference between miximum and minimum treatment volume which absorbed over the described dose-that is, 350 cGy or 400 cGy-in each patient. Results The mean of distance from rectum to A point was 4.44cm, and the mean of interfractionation distance variation was 1.14 cm in right side,1.09 cm in left side. The mean of bladder and rectum dose ratio was $63.8\%$ and $63.1\%$ and the mean of interfractionation variation was $14.9\%$ and $15.8\%$ respectively. With fixed planning administration of same planning to all fractionations as in first fractionation planning-mean of bladder and rectum dose ratio was $64.9\%$ and $72.3\%$.and the mean of interfraction variation was $28.1\%$ and $48.1\%$ reapectively. The mean of treatment volume was $84.15cm^3$ and the interfractionation variation was $21.47cm^2$. Conclusion : From these data, it was confirmed that there should be adapted planning for every fractionation ,and that confirmation device installed in ICR room would reduce the interfractionation variation due to more stable applicator configuration.

  • PDF

Variation in the Main Kuroshio Path South of Japan

  • Sekine, Yoshihiko
    • Journal of the korean society of oceanography
    • /
    • v.37 no.3
    • /
    • pp.196-200
    • /
    • 2002
  • The time variation in the Kuroshio is studied by use of nine observed distances of the main Kuroshio axis from the Japanese coast. The observed distances over 1975 - 1995 are estimated from the Prompt Report of Oceanographic Conditions published by Hydrographic Department of the Maritime Safety Agency of Japan. It is shown that large sea level difference between Naze and Nishinoomote, which represents the volume transport of the southern inflow south of Kyushu, coincides with larger distance of the Kuroshio in the upstream area from off Kyushu to off eastern Kii Peninsula and smaller distance in the downstream area from off Omae-zaki to off Boso Peninsula. In contrast, large sea level difference between Nishinoomote and Aburatsu, which represents the volume transport of northern inflow south of Kyushu, corresponds to smaller distance in the upstream area and larger distance in the downstream area. Path dynamics of the Kuroshio is discussed with reference to the variation in Volume transport south of Kyushu.

Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study - (복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study-)

  • Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

A Research on Forage Yield and Its Components In Response to Different Sowing Rate and Row Distance of Sorghum (Sorghum bicolor Moench.) in Turkey

  • Altin, Murat;Tekeli, A.-Servet;Orak, Adnan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.18 no.2
    • /
    • pp.163-170
    • /
    • 1998
  • This research was carried out to determine the sowing rate and row distance in Edirne province of Thrace Region in 1993 season. According to the results of some important characteristics of sorghum and their interactions were statistically significant. In Havsa and Uzunk'opr& the plant height were 70.36 and 95.28cm respectively, within each sowing rate were not significant. Number of tiller were not significant in distance and individual location Increasing the sowing rate kom I to 3 kg/da and the location Havsa and Umnkoprii resulted in significant stem diameter variation. Variation in 6-esh fodder yield has been found significant in row distance sowing rate and location 1 kglda seed rate with 30 cm row distance together are recommended to the farmer community to obtain the optimum profit.

  • PDF

Language Variation and World Englishes (언어변이와 세계영어들)

  • Kim, Yangsoon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.234-239
    • /
    • 2021
  • The purpose of this paper is to find out the nature of language variation by exploring the ways of the progress of the language variation that produces all English-lects, i.e., the World Englishes. The study of language variation in linguistics is a hybrid enterprise, so the study of World Englishes has led to the recognition of a highly diverse set of all English-lects, encompassing regional dialects, sociolects, ethnolects and (post-)colonial dialects of World Englishes. In this paper, we propose a hybrid language variation model with three interacting factors of social distancing, on/off-contact, and linguistic diversity to examine the characteristics of language variation. In the context of World Englishes, the social distance is typically low in terms of their local location (country/speech) for local purposes. The social distance also varies based on online/offline communication modes and other social factors like gender, age and ethnic groups, resulting in all English-lects. To clarify the nature of World Englishes, the core Englishes, BrE, AmE and CanE are discussed here.

레이져 절단에서 노즐이 미치는 영향

  • 이호준;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.81-85
    • /
    • 1992
  • Quality of cut is strongly dependent on the cutting pressure, so this relationship can be identified by pressure measuring system. In this paper, the experiments presented were performed with the devised pressure measuring system and the laser cutting of STS 304. Convergent type and convergent-divergent type nozzle were used for pressure variation of the distance between nozzle and workpiece. In laser cutting of STS 304, 1.0 kW CO $\_$2/ laser used. The convergent type nozzle(1.0 mm diameter) pressured above 3 kgf/cm $\^$2/, the MSD(Mach Shock Disk) created, which caused the the pressure variations of the distance between nozzle and workpiece. The maximum cutting pressure exists in accordance with the variation of distance. In spite of far distance the maximum cutting pressure is achieved by using the pressure measuring system. The higher cutting pressure beneath the workpiece the less quantity of dross and the kerf width. Since the higher cutting pressure helps to remove the quantity of dross and to stop the exothermic energy into the material. The optimum laser cutting parameter of STS 304(2.0 mm thickness) with the convergent type nozzle(1.0 mm diameter)is 0.75 mm and 2.5 mm distance between nozzle and workpiece, 4 kgf/cm $\^$2/ cutting pressure. In 3.0 mm thickness case, 1.5 mm and 2.25 mm distance is achieved for good quality.

An improvement algorithm for localization using adjacent node and distance variation analysis techniques in a ship (근접노드와 거리변화량분석기법을 이용한 선내 위치인식 개선 알고리즘)

  • Seong, Ju-Hyeon;Lim, Tae-Woo;Kim, Jong-Su;Park, Sang-Gug;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.213-219
    • /
    • 2013
  • Recently, with the rapid advancement in information and communication technology, indoor location-based services(LBSs) that require precise position tracking have been actively studied with outdoor-LBS using GPS. However, in case of a ship which consists of steel structure, it is difficult to measure a precise localization due to significant ranging error by the diffraction and refraction of radio waves. In order to reduce location measurement errors that occur in these indoor environments, this paper presents distance compensation algorithms that are suitable for a narrow passage such as ship corridors without any additional sensors by using UWB(Ultra-wide-band), which is robust to multi-path and has an error in the range of a few centimeters in free space. These improvement methods are that Pythagorean theory and adjacent node technique are used to solve the distance error due to the node deployment and distance variation analysis technique is applied to reduce the ranging errors which are significantly fluctuated in the corner section. The experimental results show that the number of nodes and the distance error are reduced to 66% and 57.41%, respectively, compared with conventional CSS(Chirp spread spectrum) method.