• Title/Summary/Keyword: Distal insertion method

Search Result 24, Processing Time 0.04 seconds

An experimental study on the dynamic teeth movement of 3 types of the insertion method of Precision-TPA for derotating the posterior teeth (Precision-TPA를 이용한 구치부 회전시 근심 및 원심삽입법에 따른 동적인 치아이동 양상에 관한 실험 연구)

  • Yang, Sung-Jae;Jung, Seong-Gweon;Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.425-433
    • /
    • 1999
  • Dr. Youn-Sic Chun and coworkers invented the new machine for getting information about the relative effectiveness of the orthodontic appliances and we named it Calorific machine. The author and colleagues used this machine to compare with tooth moving mechanism by 3 types of the insertion method of precision-TPA for derotating the posterior teeth. We measured the distance of tooth movement and found out the rotational center on the occlusal X-ray film and the tooth movement on the occlusogram and then processed paired t-test by SAS program, The results were as follows : 1. In the intermolar width, the mesial insertion method showed the loss oi distance, and the other methods(-distal insertion method, mesial expansion method-) showed the increase of distance. 2. In the arch length, the distal insertion method was exhibited as most recommandable way for increasing the arch length .3. The rotation center of the mesial insertion method for derotating the molar, was located between mesial pit and central pit of the lower End molar. And, in the distal insertion method, it was located between distal pit and distolingual cusp, and in the mesial expansion method was located at distal pit.

  • PDF

Percutaneous Biliary Metallic Stent Insertion in Patients with Malignant Duodenobiliary Obstruction: Outcomes and Factors Influencing Biliary Stent Patency

  • Ji Hye Kwon;Dong Il Gwon;Jong Woo Kim;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon;Kyu-Bo Sung
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.695-706
    • /
    • 2020
  • Objective: To investigate the technical and clinical efficacy of the percutaneous insertion of a biliary metallic stent, and to identify the factors associated with biliary stent dysfunction in patients with malignant duodenobiliary obstruction. Materials and Methods: The medical records of 70 patients (39 men and 31 women; mean age, 63 years; range, 38-90 years) who were treated for malignant duodenobiliary obstruction at our institution between April 2007 and December 2018, were retrospectively reviewed. Variables found significant by univariate log-rank analysis (p < 0.2) were considered as suitable candidates for a multiple Cox's proportional hazard model. Results: The biliary stents were successfully placed in all 70 study patients. Biliary stent insertion with subsequent duodenal stent insertion was performed in 33 patients and duodenal stent insertion with subsequent biliary stent insertion was performed in the other 37 study subjects. The median patient survival and stent patency time were 107 days (95% confidence interval [CI], 78-135 days) and 270 days (95% CI, 95-444 days), respectively. Biliary stent dysfunction was observed in 24 (34.3%) cases. Multiple Cox's proportional hazard analysis revealed that the location of the distal biliary stent was the only independent factor affecting biliary stent patency (hazard ratio, 3.771; 95% CI, 1.157-12.283). The median biliary stent patency was significantly longer in patients in whom the distal end of the biliary stent was beyond the distal end of the duodenal stent (median, 327 days; 95% CI, 249-450 days), rather than within the duodenal stent (median, 170 days; 95% CI, 115-225 days). Conclusion: The percutaneous insertion of the biliary metallic stent appears to be a technically feasible, safe, and effective method of treating malignant duodenobiliary obstruction. In addition, a biliary stent system with a distal end located beyond the distal end of the duodenal stent will contribute towards longer stent patency in these patients.

A technique for insertion of a long T-tube in tracheal stenosis (기관 협착에서 Long T-tube의 삽입 방법)

  • 백만종
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.664-666
    • /
    • 1993
  • A technique for insertion of a long silicone T-tube in patient with critical stenosis and high-risk resection and primary anastomosis of long segment of the distal trachea is presented. It was not easy to insert a long T-tube by existing methods because of flexibility of a T-tube and tightness of stenosis. So we used a silastic endotracheal tube and guiding wire as stylet of a T-tube. During insertion, ventilation was normally maintained through the lumen of endotracheal tube. This provided rapid relief from airway obstruction and asphyxation and is a easy, safe and effective method to restore patency of the major airways.

  • PDF

Percutaneous Insertion of the Distal Catheter during Ventriculo-Atrial Shunts. A Simple and Reliable Method

  • Kim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.6
    • /
    • pp.429-431
    • /
    • 2007
  • Although the ventriculo-peritoneal shunt is the treatment of choice when hydrocephalus should be corrected, the ventriculo-atrial shunt still holds strong alternative when the peritonium is precluded due to the several reasons. During the ventriculo-atrial shunt operation, it is not always easy to dissect and find the corresponding venous structures. In this technical note, the author describes a simple method of percutaneous insertion for placement of the atrial end.

Loop Suture Technique for Flexor Digitorum Profundus Tendon Repair in the Insertion Site (고리 봉합법을 이용한 심부 수지 굴건 종지부에서의 건봉합)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.650-658
    • /
    • 2010
  • Purpose: In the case of repair for far distal parts of FDP (Flexor digitorum profundus) division, the method of either pull-out suture or fixation of tendon to the distal phalanx is preferred. In this paper, the results of a modified loop suture technique used for the complete division of FDP from both zone 1a and distal parts of zone 1b in Moiemen classification are presented. Methods: From July 2006 to July 2009, the modified loop suture technique was used for the 10 cases of FDP in complete division from zone 1a and distal parts of zone 1b, especially where insertion sites were less than 1 cm apart from a tendon of a stump. In a suture technique, a loop is applied to each distal and proximal parts of tendon respectively. Core suture of 2-strand and epitendinous suture are done with PDS 4-0. Out of 10 patients, the study was done on 6 patients who were available for the followup. The average age of the patients was 49.1 years (in the range from 26 to 67). 5 males and 1 female patients were involved in this study. There were 3 cases with zone 1a and distal parts of zone 1b. The average distance to the distal tendon end was 0.6 cm. There were 5 cases underwent microsurgical repair where both artery and nerve divided. One case of only tendon displacement was presented. The dorsal protective splint was kept for 5 weeks on average. The results of the following tests were measured: active & passive range of motion, grip strength test, key pinch and pulp pinch test. Results: The follow-up period on average was 11 months, in the range from 2 to 20 months. There was no case of re-rupture, but tenolysis was performed in 1 cases. In all 6 cases, the average active range of motion of distal interphalangeal joint was 50.8 degree. The grip strength (ipsilateral/contralateral) was measured as 88.7% and the pulp pinch test was 79.2% as those of contralateral side. Flexion contracture was presented in 2 cases (15 degree on average) and there was no quadrigia effect found. Conclusion: Despite short length of tendon from the insertion site in FDS rupture in zone 1a and distal parts of zone 1b, sufficient functional recovery could be expected with the tendon to tendon repair using the modified loop suture technique.

Reconstruction of the Finger using Rerouting the Transverse Digital Palmar Arch in the Crushing or Avulsion Injured Finger (짓니긴 및 벗겨진 손상에서 가로손가락손바닥활을 이용한 손가락 재건)

  • Choi, Hwan-Jun;Lee, In-Soo;Choi, Chang-Yong;Kim, Mi-Sun;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.59-66
    • /
    • 2010
  • Purpose: In the finger, there are three major palmar arches in the arterial system. The location of this arches are constant. The middle and distal transverse arches are consistently large (almost 1 mm) and may be used for arterial vessel repairs either proximally or distally, depending on the length and direction needed. This paper describes our experiences in reconstruction and replantation of the finger using rerouting the transverse digital palmar arch. Methods: 31 patients with injuries according to our classification were treated from March of 2005 to October of 2008. In this study the authors subdivided injuries into those with amputation distal to the insertion of the flexor digitorum profundus (Class I, 31 fingers); those with amputation distal to the insertion of the flexor digitorum superficialis (Class II, 4 fingers). Replantation was performed using the artery-only technique with neither vein nor nerve repair. Because the artery has been damaged, it is still possible to make a direct suture by transposing the arterial arch in an inverted Y to I arterial configuration or converting the arch. Venous drainage was provided by an external bleeding method with partial nail excision, medical leech, and repaired margin. Results: The success rate was 87% (n=27) in class I and 75% (n=4) in class II. The authors conclude that crushing and complete avulsion injuries & amputations are salvageable, with acceptable functional results in select patients, especially those with amputation distal to the insertion of the flexor digitorum superficialis. Conclusion: We performed replantation and reconstruction with only-arterial transposing anastomosis successfully, resulting in good recovery of aesthetic and functional outcome. Three major digital palmar arches, especially distal two branches, give us additional treatment options. In the finger replantation and reconstructive techniques using rerouting healthy the transverse digital palmar arch increase the survival rate of the finger.

DEVELOPMENT OF PREDICTABLE STABILITY TEST FOR ASSESSMENT OF OPTIMUM LOADING TIME IN DENTAL IMPLANT

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kwon, Ji-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.628-633
    • /
    • 2008
  • STATEMENT OF PROBLEM: The application of a simple, clinically applicable noninvasive test to assess implant stability are considered highly desirable. So far there is still a controversy about correlation of various tests and implant stability. PURPOSE: In order to assess implant stability, the development of a new method is critical. It's possible to assess implant stability by calculating energy and angular momentum during implant installation. The purpose of this study is to evaluate the correlation of energy and implant stability. MATERIAL AND METHODS: Twenty three implants were installed in two different types of pig bone. Type I bone was retrieved from the distal aspect of the rib, with more cortical bone. Type II bone came from a more proximal region with less cortical components and a higher content of bone marrow and spongeous trabeculae. Insertion torque, removal torque, ISQ values and angular momentum and energy were measured. Pearson Correlation test was done to analyze the relation between RFA, maximum insertion torque, mean insertion torque, bone type, energy and removal torque. RESULTS: Type I bone showed higher removal torque than type II bone. Energy value was significantly correlated with maximum insertion torque and mean insertion torque. RFA values were related with insertion torques but the significance was lower than Energy value. CONCLUSION: Within the limitation of this study energy values were considered clinically predictable method to measure the implant stability.

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

Usefulness of the double-guidewire technique for endoscopic procedures in the field of biliary and pancreatic diseases

  • Mamoru Takenaka;Masatoshi Kudo
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.605-614
    • /
    • 2022
  • The double-guidewire method has been increasingly used in endoscopic procedures for biliary and pancreatic diseases in recent years, including endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography-related procedures. In addition, double-lumen catheters with uneven distal and proximal lumen openings have been introduced, making it possible to easily create a double-guidewire situation, and the usefulness of the double-guidewire technique using uneven double-lumen cannulas has been widely reported. Although the advantages of using two guidewires depend on the particular situation and the appropriate use of the two guidewires, deepening the knowledge of the double-guidewire method will contribute greatly to troubleshooting in daily practice. In this review, the usefulness of the double-guidewire technique is discussed with respect to two main areas: selective insertion of guidewires and devices and biliary cannulation.

Congenital Cystic Adenomatoid Malformation(CCAM) (선천성 낭포성 유선종 기형)

  • 김수원
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.1084-1094
    • /
    • 1988
  • Conservative management of 3 iatrogenic perforations of intrathoracic esophagus was reviewed. The primary disorders were achalasia in 2 patients and congenital tracheoesophageal fistula in 1 patient. Perforation occurred after treatment of the primary disorders in the distal esophagus in 2 patients and mid-thoracic esophagus in 1 patient. All the perforations appeared late after the previous treatments and the inflammation spread to mediastinum and pleural cavity in all the 3 patients. Conservative management of esophageal perforation was carried out with intraluminal drainage from the perforated site of esophagus[insertion of Levin`s tube and continuous suction], pleural drainage and feeding of liquid diet through gastrostomy tube with Fowler`s position. The patients revealed spontaneous closure of perforated sites about 3 to 4 weeks after this conservative management without open thoracotomy. This result suggests that this conservative management may be accepted as therapeutic method in the thoracic esophageal perforations regardless of cause and time of the perforation.

  • PDF