• Title/Summary/Keyword: Dissolved oxygen (DO)

Search Result 486, Processing Time 0.028 seconds

APPLICATION OF A PILOT-SCALE FLUIDIZED-BED REACTOR FOR THE DECONTAMINATION OF GROUNDWATER

  • Ohlen, Ken;Lee, Seong-Taek;Hegemann, Wemer;Jang, Yong-Geun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.77-80
    • /
    • 2001
  • Groundwater, contaminated predominantly with aromatic compounds and chlorinated ethylene, could be biologically treated in a fluidized-bed reactor with immobilized cells. The decomposition efficiency for the aromatics was over 90% at the retention time of 2.5 h. The chlorinated ethylenes, especially trichloroethylene (TCE) and cis-dichloroethylene (DCE), could be decomposed only insufficiently. No anaerobic methane formation was observed for this groundwater even at a very low dissolved oxygen (DO) concentration of 0.75 mg/L. The variation of DO concentration resulted in an optimal value of 1.5 mg/L. The recycle of air waste could increase the utilization of oxygen. The amount of low boiling pollutants stripped out remained constant with the recycle, while for the higher boiling pollutants the stripping slightly increased. Using air instead of oxygen increases the flow rate of air waste, which is connected to a higher stripping of pollutants. In this investigation, the pollutant concentration in the air waste remained constant. The stripping of main pollutants did not exceed 0.3 %.

  • PDF

Influence of Landuse Pattern and Seasonal Precipitation on the Long-term Physico-chemical Water Quality in Namhan River Watershed (남한강 수계에서 장기 이화학적 수질특성에 대한 토지이용도 및 계절성 강우의 영향)

  • Lee, Ji-Eun;Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1115-1129
    • /
    • 2012
  • The objective of this study was to analyze long-term annual and seasonal trends of water chemistry on landuse patterns and seasonal precipitation using 72 sampling sites within Namhan River watershed during 2001-2010. Water quality, based on multi-parameters of water temperature(WT), dissolved oxygen(DO), biochemical oxygen demand(BOD), chemical oxygen demand(COD), suspended solids(SS), total nitrogen(TN), total phosphorus(TP), and electric conductivity(EC) varied largely depending on monsoon rain and landuse patterns such as forest, cropland, and residence. Concentrations of BOD and COD as an indicator for organic matter pollution, increased during summer monsoon season at the cropland and residential streams. Values of TN and TP were higher in residential streams than in the forest and cropland streams. In the meantime, DO values had weak relations to the landuse patterns of forest and cropland cover. Water quality was worst in cropland and residential streams, and also most degradated in 4th order streams. Overall, our results suggest that efficient water quality management is required in the cropland and residential landuse streams.

Removal of Waste Generated by Flounder (Paralichthys olivaceus) in Aquarium using a Foam Separator (활어수조에서 넙치 사육시 포말분리장치를 이용한 오염물 제거)

  • SHIN Jeong-Sik;LEE Chang-Kuen;JEONG Ho-Su;LEE Min-Su;LEE Jin-Kyung;SUH Keun-Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.498-504
    • /
    • 2004
  • Removal of waste generated by Paralichthys olivaceus in the seawater aquarium using a foam separator was investigated. Protein concentration without a foam separator continuously increased until 3 days after stocking and reached at 25 mg/L after 5 days stocking, but protein concentration became lower than the initial protein concentration (2.5 mg/L) with a foam separator. The trends of other fish wastes such as ammonia, total suspended solids (TSS) and chemical oxygen demand (COD) were similar to protein. Dissolved oxygen (DO) in the aquarium decreased below 6.0 mg/L without a foam separator, but with a foam separator the average DO in the aquarium was 7.3 mg/L. Foam separation with the increase of superficial air velocity (SAV) was more effective than that with the fixed SAV. This study showed that wastewater. treatment of seawater aquarium using a foam separator is effective method for a fish waste removal and oxygen supply.

Feasibility Study on Production of Liquid Fertilizer in a 1 ㎥ Reactor Using Fishmeal Wastewater for Commercialization

  • Gwon, Byeong-Geun;Kim, Joong-Kyun
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.3-8
    • /
    • 2012
  • A scaled-up bioconversion of fishmeal wastewater (FMW) into liquid fertilizer was performed five times in a $1m^3$ reactor in order to examine the feasibility of commercialization. The importance of aeration was marked. Analyses indicated that dissolved oxygen (DO) level was closely related to the value of oxidation-reduction potential (ORP) and it was crucial to achieve high-quality liquid fertilizer. When pure oxygen was supplied through four diffusers into the reactor, DO levels and ORP values were maintained over 1.2 mg/L and 0.2 mV, respectively all the time during 52 hr of bioconversion. The pH changed from 6.8 to 5.9. The average removal percentages of chemical oxygen demand ($COD_{Cr}$) and total nitrogen (TN) were 75.0% and 71.6%, respectively. Compared to the result acquired in a 5-L reactor, bioconversion of FMW into liquid fertilizer was achieved in a shorter time under the same removal percentages of $COD_{Cr}$ and TN. The 52-hr culture of inoculated FMW was phytotoxic-free and it possessed comparable fertilizing ability to a liquid fertilizer made from the fish waste in hydroponic culture with amino acid contents of 5.93 g/ 100 g sample. From all the above results, transferring lab-scale data to large-scale production appeared to be successful. As a result, the commercialization of a liquid fertilizer made from FMW was feasible.

Analyses of TOC Efficiency and Correlation between DO, BOD, COD and Influence Factors using Long-term Observation Data in the Main Stream of Nakdong River (낙동강 본류에서 장기관측 자료를 이용한 DO, BOD, COD와 그 영향인자의 상관관계 및 TOC 분해율)

  • Kang, Dong-hwan;So, Yoon Hwan;Park, Kyeong-deok;Kim, Il-kyu;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.28 no.5
    • /
    • pp.465-474
    • /
    • 2019
  • Herein, we analyzed the spatial and temporal variation of DO (dissolved oxygen), BOD (biochemical oxygen demand), and COD (Chemical Oxygen Demand) with the monthly mean observed data for 10 years (2008~2017) in the main stream of the Nakdong River. The water quality of the stations declined in a downstream direction, with the BOD and COD showing their highest values at the ST5 station. From the analysis of the correlation of water quality components at 10 stations, the correlation coefficient between the DO and water temperature was more than -0.90, and that between BOD and Chl-a was 0.48~0.85, and that between COD and TOC was more than 0.65 except for the ST5 and ST10 stations. From the regression analysis using data collected from all stations, the water temperature and DO decreased linearly with a coefficient of determination of 0.90, and the Chl-a and BOD could be described by increasing power functions with a coefficient of determination of 0.83. The TOC and COD followed increasing logarithm functions with a coefficient of determination of 0.58. The TOC efficiency at the 10 stations was estimated and the average efficiencies of BOD and COD were 15.5~36.3% and 57.4~89.6%, respectively.

Nitrogen and Phosphorus Removal in Membrane Bio-Reactor (MBR) Using Simultaneous Nitrification and Denitrification (SND) (동시 질산화-탈질(SND) 반응을 적용한 MBR 반응조에서 질소 및 인 제거 특성)

  • Tian, Dong-Jie;Lim, Hyun-Suk;An, Chan-Hyun;Lee, Bong-Gyu;Jun, Hang-Bae;Park, Chan-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.724-729
    • /
    • 2013
  • Simultaneous nitrification and denitrification (SND) occurs concurrently in the same reactor under micro dissolved oxygen (DO) conditions. Anaerobic zone was applied for phosphorus release prior to an aerated membrane bio-reactor (MBR), and anoxic zone was installed by placing a baffle in the MBR for enhancing denitrification even in high DO concentration in the MBR. Phosphorus removal was tested by alum coagulation in the anaerobic reactor preceding to MBR. DO concentration were 2.0, 1.5, 1.0, 0.75 mg/L in the MBR at different operating stages for finding optimum DO concentration in MBR for nitrogen removal by SND. pH was maintained at 7.0~8.0 without addition of alkaline solution even with alum addition due to high alkalinity in the raw sewage. Both TCODcr and $NH_4^+$-N removal efficiency were over 90% at all DO concentration. TN removal efficiencies were 50, 51, 54, 66% at DO concentration of 2.0, 1.5, 1.0, 0.75 mg/L, respectively. At DO concentration of 0.75 mg/L with addition of alum, TN removal efficiency decreased to 54%. TP removal efficiency increased from 29% to 95% by adding alum to anaerobic reactor. The period of chemical backwashing of the membrane module increased from 15~20 days to 40~50 days after addition of alum.

Relationship between Microflora and Environmental Factors in Groundwater (지하수 미생물과 환경요인의 상호관계)

  • 안연준;민병례;최영길
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 1995
  • This study was conducted to find out the relationship between microflora in groundwater and its physico-chemical environmental factors at the 59 sites, where distributed at 3 cities and 18 counties in Jeonranam-Do, Korea. The average values of environmental factors were as followings; pH 6.9, temperature 20.1 $^{\circ}C$, dissolved oxygen 6.5 mg/1, the depth of wells 80.1 m, and nitrate 10.7 mg/1. The average value of microbial population size; Heterotrophic bacteria-NA (HPC-NA) and heterotrophic bacteria-YEPD (HPC-YEPD) were 1.4${\times}$10$^3$CFU/ml and 0.59${\times}$10$^3$ CFU/ml respectively HPC-YEPD numbers were 42.1% of HPC-YEPD. Coliform bacteria were detected at 16 sites, and its average numbers were 6.7 CFU/ml. General fungi were detected at 14 sites, and its had average numbers were 3.9 CFU/ml. The correlation coefficient was calculated value as relation index between the microbial population sizes and environmental factors in groundwater. In case of HPC-NA, the correlation coefficient value with dissolved oxygen was 0.087 But it showed negative correlation coefficient with other factors. In case of HPC-YEPD, the correlation coefficient value with pH, temperature and nitrate were 0.0957, 0.0019 and 0.0151 respectively. It was concluded that the population size of HPC-NA were influenced by the order of temperature, dissolved oxygen, pH and the depth of wells and that HPC-YEPD were influenced by the order of pH, dissolved oxygen, nitrate, the depth of wells and temperature.

  • PDF

Dynamic Changes of Dissolved Oxygen during Summer Monsoon (하절기 장마동안 용존산소의 역동적 변화)

  • An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.213-221
    • /
    • 2000
  • Seasonal oxygen content and deficit rates were evaluated from 17 sites of Taechung Reservoir during 1993${\sim}$1994. In 1993, river inflows peaked during the monsoon in July${\sim}$August and disrupted thermal stratification and anoxic layers in the headwaters, thereby confining the anoxia to the mid-lake and downlake reach. The volume of anoxic water with < 4 mg/l DO comprised only < 10% of the total lake volume in this period. In contrast, during monsoon 1994, 85% of total lake volume was subject to hypoxic conditions with oxygen concentrations < 30% saturation, resulting in massive fishkills (Hypomesus olidus). Relative areal oxygen deficit (RAOD) was -0.024mg O$_{2}$cm$^{-2}$d$^{-1}$ during monsoon 1993, whereas it rapidly decreased at the rate of 0.080mg O$_{2}$cm$^{-2}$d$^{-1}$ during monsoon 1994. Anoxic factor (AF) showed a same interannual pattern as the RAOD and was greater >50 d in 1994 (76.5 d) than 1993 (21.3 d). Thus, the reservoir showed a river-characteristics (6${\sim}$11 mg/l DO) in 1993 while lacustrine conditions (<4mg/l DO) dominated in 1994. Regression analysis showed that the variation of summer DO was mostly determined (R$^{2}$=0.99, p<0.0001) by inflow. These findings suggest that the primary factor regulating the oxygen content in this system during summer is an intensity of the monsoon rain.

  • PDF

Operation diagnostic based on PCA for wastewater treatment (PCA를 이용한 하폐수처리시설 운전상태진단)

  • Jeon Byeong-Hui;Park Jang-Hwan;Jeon Myeong-Geun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.96-98
    • /
    • 2006
  • 축산폐수는 축사가 대부분 상수원보다 상류지역에 산재하고 있어 이를 효과적으로 관리하기 어려우나, 연속 회분식 반응기(Sequencing Batch Reactor, SBR)는 장치가 간단하고 경제성이 우수하여 축산폐수처리에서 효율적으로 적용될 수 있다. 본 연구에서는 DO(Dissolved Oxygen)과 ORP(Oxidation-Reduction Potential)을 이용하여 지식기반 고장진단 시스템을 제안하였다. 실시간으로 얻어진 ORP, DO값들을 전처리하여, [ORP], [DO]외에 [ORP DO]합성data와 ORP, DO의 특징백터의 합에서 얻어진 fusion data의 총 4개의 data set을 이용하여 각각에 대한 진단과 분류성능을 검토하였다. 이 값을 이용하여 FCM (fuzzy C-mean) 클러스터링 한 후, K-PCA과 LDA로 차원축소시켜 특징백터를 추출하였다. 그리고 Hamming distance로 test data와 특징백터의 거리를 계산하여 각 class를 F1에서 F8까지 분류하였다. 그 결과 데이터를 그대로 이용하는 것 보다 차분데이터형태로 이용하는 것이 우수했으며 그 중 fusion 데이터의 결과가 다른 것들보다 향상된 결과를 보였다. 그리고 K-PCA와 LDA를 결합한 결과가 다른 방법에 비해 우수한 결과를 보였으며 fusion method를 이용한 최고인식율은 98.02%를 나타내었다.

  • PDF