• Title/Summary/Keyword: Dissolved hydrogen

Search Result 210, Processing Time 0.023 seconds

Performance Evaluation of Hydrogen Separation and Generator for Hydrogen Water (수소수를 위한 수소분리 및 생성기 성능 평가)

  • Kim, Gui-Jung;Han, Jung-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.281-286
    • /
    • 2016
  • In this paper, we optimized the structure of hydrogen water generator and assessed by developing a generator with dissolved hydrogen amount(1,000~1,200 ppb) of world-class level. Evaluation is divided into four types, such as dissolved hydrogen amount, pH, maximum pressure, redox potential, and it was evaluated for each of the targets. It was performed through the experiment of four in all five times and all of them show superiority results appearing in the target range. In addition, the assessment got 25/30 functionality, 17/20 maintainability, 26/30 usability, and 19/20 efficiency. In particular, we proved the validity of this study in high efficiency. We developed this hydrogen water generator system as possible to be substitution of water purifier.

제주도 한라산 남북측 사면 용천수의 수리지구화학

  • 이광식;박원배;현승규;김용제;문덕철;김구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.408-412
    • /
    • 2004
  • A total of 23 springs distributed in the southern and northern sides of Mt. Hala in Jeju Island were seasonally sampled and analyzed for their major ion chemistry and oxygen and hydrogen isotope compositions to investigate their hydrogeochemical and isotopic characteristics. Dissolved ion concentrations of the south-side springs slightly increase with decreasing altitude. This indicates that dissolved ion concentrations of groundwater recharged at higher altitudes increase by water-rock interaction during the downgradient migration of groundwater through highly permeable volcanic aquifer. Dissolved ion concentrations of the north-side springs also slightly increase with decreasing altitude, but dramatically increase at ~300 m.a.s.l. This may indicate a sudden input of contaminants to the north-side groundwater system around ~300 m.a.s.l. Springs located in areas above ~300 m.a.s.l. have very low concentrations of dissolved ions, showing little seasonal variations. Whereas springs located in areas below ~300 m.a.s.l. show a big seasonal variation in the concentration of dissolved ions. Seasonal variation of oxygen isotope compositions of springs is ~3$\textperthousand$ for high-altitude springs (~1700 m.a.s.l.) and is ~2$\textperthousand$ near shore, indicating an attenuation of the variation through mixing with other groundwater bodies during migration.

  • PDF

Fabrication and Characteristics of Pd/Pt Gate MISFET Sensor for Dissolved Hydrogen in Oil (유중 용존수소 감지를 위한 Pd/Pt Gate MISFET 센서의 제조와 그 특성)

  • Baek, Tae-Sung;Lee, Jae-Gon;Choin, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.41-46
    • /
    • 1996
  • The Pd/Pt gate MISFET type hydrogen sensors, for detecting dissolved hydrogen gas in the transformer oil, were fabricated and their characteristics were investigated. These sensors including diffused resister heater and temperature monitoring diode were fabricated on the same chip by a conventional silicon process technique. The differential pair plays a role in minimizing the intrinsic voltage drift of the MISFET. To avoid the drift of the sensors induced by the hydrogen, the gate insulators of both FETs were constructed with double layers of silicon dioxide and silicon nitride. In order to eliminate the blister formation on the surface of the hydrogen sensing gate metal, Pt and Pd double metal layers were deposited on the gate insulator. The hydrogen response of the Pd/Pt gate MISFET suggests that the proposed sensor can detect the dissolved hydrogen in transformer oil with 40mV/10ppm of sensitivity and 0.14mV/day of stability.

  • PDF

Evaluation of Advanced Oxidation Process(AOP) as a Pretreatment Process of Biological Activated Carbon in Drinking Water Treatment (정수처리에서 생물활성탄의 전처리로서 고급산화처리법의 평가)

  • Kim Woo-Hang
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.725-730
    • /
    • 1999
  • The advanced oxidation process (AOP) using ozone combined with hydrogen peroxide and ultraviolet treatment were evaluated for biodegradable dissolved organic carbon (EDOC) formation and dissolved organic carbon (DOC) removal. Oxidation treatment were conducted alone or combination with ozone, hydrogen peroxide and ultraviolet processes. Ozone dosage of ozone process was varied from $0.5mg/l{\ell}\cdot}min$ to $5mg/{\ell}{\cdot}min$. Ozone/hydrogen peroxide process was done using $20mg/{\ell}{\cdot}min$ of hydrogen peroxide concentration. Ozone/ultraviolet process was irradiated with $12mW/cm^2$ of density and 254nm. Ozone dosage was varied from $0.5mg/{\ell}{\cdot}min$ to $5mg/{\ell}{\cdot}min$ at the ozone/hydrogen peroxide and ozone/ultraviolet processes too. Contact time of all the process was 20 minutes. Oxidation treatment were performed on microfiltration effluent samples. BDOC formation was reached to an optimum at ozone dosage of $1.5mg/{\ell}{\cdot}min$ in the ozone/hydrogen peroxide process and $1mg/{\ell}{\cdot}min$ in ozone/ultraviolet process, after which BDOC formation was decreased at higher ozone dosages. But BDOC formation was increased with ozone dosages increasing in ozone process. The efficiency of DOC removal was higher AOPs than ozone process. Ozone/ultraviolet proces was the highest for DOC removal efficiency in each process. THMFP. removal efficiency by ozone/ultraviolet process was higher than that by each of ozone process and ozone/hydrogen peroxide process.

  • PDF

Sorption and Degradation of Benzene by Hydrogen Peroxide and Microorganism in a Sandy Soil (사질토양에서의 과산화수소 및 미생물에 의한 Benzene의 흡착 및 분해)

  • 백두성;박춘화;김동주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.101-107
    • /
    • 2000
  • Column tests using KCl and Benzene as tracers were conducted for four different cases: 1) no hydrogen peroxide and no microorganism; 2) hydrogen peroxide only; 3) microorganism only; 4) hydrogen and microorganism to investigate the sorption and degradation characteristics of Benzene. The observed BTCs of KCl and Benzene in all cases showed that the arrival times of the peaks of both tracers coincided well but the peak concentration of Benzene was much lower than that of KCl. This result reveals that a predominant process affecting the transport of Benzene in a sandy soil is an irreversible sorption and/or degradation rather than retardation. Decay of Benzene through sorption and degradation increased with the addition of hydrogen peroxide and/or microorganism. Dissolved oxygen decreased with the increase of Benzene in all cases indicating that Benzene was degraded by dissolved oxygen. For BTCs with the addition of microorganisms (case 3 and case 4), microorganism showed much lower concentrations compared to the initial levels and an increasing tendency with time although concentrations of Benzene returned to zero, indicating a possible retardation of microorganism due to reversible and irreversible sorption to the particle surfaces.

  • PDF

Solid Electrochemical Method of Measuring Hydrogen Concentration with O2-/H+ Hetero-Ionic Junction

  • Chongook Park
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.63-69
    • /
    • 2024
  • A novel method for measuring hydrogen concentration is introduced, along with its working principle and a novel detection algorithm. This configuration requires no additional reference compartment for potentiometric electrochemical measurements; therefore, it is the most suitable for measuring dissolved hydrogen in the liquid phase. The sensor's electromotive force saturates at a certain point, depending on the hydrogen concentration during the heating process of the sensor operation. This dynamic temperature scanning method provides higher sensitivity than the constant temperature measurement method.

Effects of the Different Level of Dissolved Oxygen, Ammonia and Hydrogen Sulfide on Survival and Growth of juvenile, Fenneropenaeus chinensis (대하, Fenneropenaeus chinensis 치하의 생존 및 성장에 미치는 빈산소, 암모니아 및 황화수소의 영향)

  • 지정훈;강주찬
    • Journal of Aquaculture
    • /
    • v.17 no.4
    • /
    • pp.235-239
    • /
    • 2004
  • Experiments were carried out to examine the effects of the different levels of oxygen, ammonia and hydrogen sulfide on survival, specific growth rate (SGR) and feed conversion ratio (FCR) of juvenile shrimp, Fenneropenaeus chinensis. Survival of the shrimp exposed to the hypoxia with $\leq$2.5 mg/L dissolved oxygen for 24 days were significantly affected. SGR and FCR of the shrimp exposed to$\leq$3.0 mg/L dissolved oxygen were significantly reduced than those of shrimp reared at 6.8 mg/L dissolved oxygen concentration. Survival of the shrimp exposed to $\geq$2.0 mg/L of ammonia levels for 24 days was significantly affected. Moreover, compared to the control group significant decrease of SGR and FCR of the shrimp has been observed with $\geq$1.0 mg/L and $\geq$0.5 mg/L of ammonia concentrations. In case of hydrogen sulfide, $\geq$0.5 mg/L was the critical level showed its significant negative effect on survival rate of shrimp exposed for 24 days. While, the group exposed with $\geq$0.07 mg/L and $\geq$0.05 mg/L hydrogen sulfide levels had a lower SGR and FCR values than did the control group in the same stipulated time of exposure.

Removal of Uranium from U-bearing Lime-Precipitate using dissolution and precipitation methods (우라늄 함유 석회침전물의 용해 및 침전에 의한 U 제거)

  • Lee, Eil-Hee;Lee, Keun-Young;Chung, Dong-Yong;Kim, Kwang-Wook;Lee, Kune-Woo;Moon, Jei-Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.77-85
    • /
    • 2012
  • This study was carried out to remove (/recover) the uranium from the Uranium-bearing Lime Precipitate (ULP). An oxidative dissolution of ULP with carbonate-acidified precipitation and a dissolution of ULP with nitric acid-hydrogen peroxide precipitation were discussed, respectively. In point of view the dissolution of uranium in ULP, nitric acid dissolution which could dissolved more than 98% of uranium was more effective than carbonate dissolution. However, in this case, uranium was dissolved together with a large amount of impurities such as Al, Ca, Fe, Mg, Si, etc. and some impurities were also co-precipitated with uranium during a hydrogen peroxide precipitation. On the other hand, in the case of carbonate dissolution-acidified precipitation, U was dissolved less than 90%. Therefore, it was less effective than nitric acid dissolution for the volume reduction of radioactive solid waste. However, it was very effective to recover the pure uranium, because impurities were hardly dissolved and hardly co-precipitated with uranium.