• Title/Summary/Keyword: Dissolved Oxygen

Search Result 1,374, Processing Time 0.052 seconds

Monitoring bridge scour using dissolved oxygen probes

  • Azhari, Faezeh;Scheel, Peter J.;Loh, Kenneth J.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.145-164
    • /
    • 2015
  • Bridge scour is the predominant cause of overwater bridge failures in North America and around the world. Several sensing systems have been developed over the years to detect the extent of scour so that preventative actions can be performed in a timely manner. These sensing systems have drawbacks, such as signal inaccuracy and discontinuity, installation difficulty, and high cost. Therefore, attempts to develop more efficient monitoring schemes continue. In this study, the viability of using optical dissolved oxygen (DO) probes for monitoring scour depths was explored. DO levels are very low in streambed sediments, as compared to the standard level of oxygen in flowing water. Therefore, scour depths can be determined by installing sensors to monitor DO levels at various depths along the buried length of a bridge pier or abutment. The measured DO is negligible when a sensor is buried but would increase significantly once scour occurs and exposes the sensor to flowing water. A set of experiments was conducted in which four dissolved oxygen probes were embedded at different soil depths in the vicinity of a mock bridge pier inside a laboratory flume simulating scour conditions. The results confirmed that DO levels jumped drastically when sensors became exposed during scour hole evolution, thereby providing discrete measurements of the maximum scour depth. Moreover, the DO probes could detect any subsequent refilling of the scour hole through the deposition of sediments. The effect of soil permeability on the sensing response time was also investigated.

A Study on the Releasing Characteristics of Organic Matter and Heavy Metals and Changes of Dissolved Oxygen Concentration during Sediment Resuspension (퇴적물 재부유에 따른 유기물과 중금속 용출 및 용존산소량 변화 특성에 대한 연구)

  • Kang, Seon Gyeong;Lee, Han Saem;Lim, Byung Ran;Rhee, Dong Seok;Shin, Hyun Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • The depletion of dissolved oxygen (DO) in urban streams has a profound effect on the aquatic ecosystem; however, the change in DO by resuspension of sediments and the cause have not been sufficiently investigated. In this study, the physicochemical properties (particle size, and the content of organic and heavy metals) of the sediments of an urban stream (Anyang Stream) and the characteristics of water quality changes (DO, dissolved organic carbon (DOC), dissolved nitrogen (DN), sediment oxygen demand (SOD), and adenosine triphosphate (ATP)) by sediment resuspension were investigated. The sediment content of fine particles (< 0.2 mm) increased from 36.7% to 52.7% from the upstream to the downstream, and the contents of heavy metals and organic matter of the sediment were also higher towards the downstream. The depletion of DO by resuspension was observed in the sediment at the downstream sites (P8, P9), where the fine particle content was high, and biological SOD (BSOD) was more than 88% compared to the total SOD. The increase in BSOD coincided with the increase in ATP. It was also confirmed that the depletion of DO could increase the amount of heavy metals (such as Fe, Mn, and Pb) released from the sediment. Based on the above results, it can be concluded that resuspension of sediments induces rapid water quality changes and may cause accidents, such as fish mortality, during rainfall, and such a water quality effect can be more pronounced in sediments with a high content of fine particles and organic matter and high biological activity.

제주도 한라산 남북측 사면 용천수의 수리지구화학

  • 이광식;박원배;현승규;김용제;문덕철;김구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.408-412
    • /
    • 2004
  • A total of 23 springs distributed in the southern and northern sides of Mt. Hala in Jeju Island were seasonally sampled and analyzed for their major ion chemistry and oxygen and hydrogen isotope compositions to investigate their hydrogeochemical and isotopic characteristics. Dissolved ion concentrations of the south-side springs slightly increase with decreasing altitude. This indicates that dissolved ion concentrations of groundwater recharged at higher altitudes increase by water-rock interaction during the downgradient migration of groundwater through highly permeable volcanic aquifer. Dissolved ion concentrations of the north-side springs also slightly increase with decreasing altitude, but dramatically increase at ~300 m.a.s.l. This may indicate a sudden input of contaminants to the north-side groundwater system around ~300 m.a.s.l. Springs located in areas above ~300 m.a.s.l. have very low concentrations of dissolved ions, showing little seasonal variations. Whereas springs located in areas below ~300 m.a.s.l. show a big seasonal variation in the concentration of dissolved ions. Seasonal variation of oxygen isotope compositions of springs is ~3$\textperthousand$ for high-altitude springs (~1700 m.a.s.l.) and is ~2$\textperthousand$ near shore, indicating an attenuation of the variation through mixing with other groundwater bodies during migration.

  • PDF

Urban Streams' Water Quality and Odor Control Using Pure Oxygen and Vortex Aerator (순산소와 Vortex Aerator를 이용한 도심하천의 수질 및 악취 관리)

  • Yoon, Dain;Choi, Mijeong;Park, Sunghyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2021
  • The target site, Goejeongcheon flows through downtown of Saha-gu, Busan and it connects to the Nakdong-gang estuary. But non-point pollutants and sewage sludge are partially flowing into the stream and deposited. As a result, dissolved oxygen concentrations of the stream were observed close to the anaerobic condition. Multistage Vortex Aerator was applied for restoring this urban stream. It dissolves oxygen by repeatedly causing collisions between water and oxygen by vortex flow. The changes in water quality and odor were monitored for 2 months while circulating 1 m3/min of water with 22 ppm dissolved oxygen. As a result of the operation, the dissolved oxygen was improved from slightly Bad (4)~Bad (5) to Good (1b)~Normal (3) grade, and the total phosphorus concentration was decreased by 76 % on average. In the case of complex odor, a maximum reduction of 84.5 % was observed on the day the entire river was anaerobic. Through this study, we evaluated the feasibility of applying pure oxygen and Vortex Aerator for the the stream restoration. It is expected that the results of this study can be used for full-scale design.

Effects of dissolved oxygen and coagulants on algal autoflotation (응집제종류 및 용존산소농도에 따른 조류의 Autoflotation효과)

  • 권오상;박혜경
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • To develop the removal technique of algal bloom the efficiencies of algal flocculation/ autoflotation by the kinds of coagulant and oversaturated oxygen concentration were investigated. The summarized results are as follow. 1. In the algae flocculation test with alum[$Al_2(SO_4)_3{\cdot}18H_2O$], optimum pH was 5.5 and, with chitosan optimum pH was 7.0. 2. Chitosan which was natural polymer showed the 5~10 times higher algal biomass flocculation efficiency than alum in the condition of same algal concentration. 3. For the each coagulant, the higher ${\Delta}DO$(oversaturated dissolved oxygen concentration - saturated dissolved oxygen) was, the faster the rising velocity of the algal floc was. 4. In the condition of about 4mg/L ${\Delta}DO$, the rising velocity of chitosan is about 2 times higher than that of alum, and chitosan formed the stronger algal floc.

  • PDF

Characteristics of Sludge Bulking Caused by Low Dissolved Oxygen in Aeration Tank for Paper Mill Wastewater Treatment (포기조의 낮은 용존산소로 인한 제지폐수의 슬러지 팽화특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Park, Jong-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.458-464
    • /
    • 2008
  • Bulking phenomena and scum formation are common problem in suspended growth system like the activated sludge plants for wastewater treatment. Apart from wastewater composition, operating conditions, such as mechanical stress by insufficient oxygen supply, are often decisive for the occurrence of a bulking or scumming problem. There were the comparative aeration tanks in terms of sludge bulking caused by the difference of mechanical aeration facilities in the wastewater treatment plant of N paper mill company. In this study the cause of bulking was investigated through not only the biological isolation and identification but also a series of operational data consideration. On the basis of the investigation results for bulking cause, the operational criteria on dissolved oxygen concentration was derived to decrease the bulking problem.

용존산소농도 조절에 의한 미생물 유래 Transglutaminasc 생산

  • Yu, Jae-Su;Jeon, Gye-Taek;Sin, Won-Seon;Jeong, Yong-Seop
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.343-346
    • /
    • 2001
  • The effect of agitation speed and aeration rate on mTG production and cell growth by Streptoverticillum morbarense was investigated. Dissolved oxygen was controlled by on-line computer-controlled fermentation system. The agitation speed and aeration rate of 2.5 L fermentor ranged from 330 to 360 게m and 1 vvm to 4 vvm, respectively. The highest mTG production was 2.1 U/mL when dissolved oxygen level was 20%, and it was improved almost 1.1 times in comparison with that without dissolved uxygen control.

  • PDF

General Oceanographic Factors In Yeongil Bay Of Korea, Late October 1973 (가을철 영일만수괴의 일반해양학적 특성)

  • Kwak, Hi-Sang
    • 한국해양학회지
    • /
    • v.11 no.2
    • /
    • pp.89-95
    • /
    • 1976
  • Some factors of seawater such as water temperature, salinity, pH, dissolved oxygen and asturation of dissolved oxygen were determined in 5 meters intervals from surface to bottom at 11 stations in Yeongil Bay of Korea during late October 1973. Distribution pattern of water masses in Yeongil Bay during the period seemed to be heterogeneous as dividing into two parts of surface and bottom. Water temperature, pH, dissolved oxygen and saturation of dissolved oxygen of surface water mass showed higher values and salinity of the mass showed lower values than those factors of bottom water mass. Surface water mass might be originated from Tsushima current during summer season and bottom water mass from cold body of East Sea of Korea which seemed to extend to coastal zone during winter season. Land water discharge from Hyeongsan River into the Bay is considered as a minor factor playing slight role in the water mass composition of the area.

  • PDF

A Study on Electric Potential Change by Pulse Voltage Polarity in Liquid (펄스전압의 극성에 따른 액중 전위변화에 관한 연구)

  • Kim Jin-Gyu;Kim Hyung-Pyo;Park Young-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • This paper proposes the new type of an ion exchange water generator system. The system has an +/- ion exchange membrane located in center and a diagonal-interdigit type electrode applied to a pulsed power. This system is studied in the liquid for the oxidation/reduction potential and the dissolved oxygen concentration by the polarity effects. Consequently, as a diagonal-interdigit type electrode is installed in each side of device, the oxidation/reduction potential and dissolved oxygen concentration by polarity changes and electrical resistivity differences be observed. An ion concentration in the ion exchange water generator system is increased by dissolved oxygen generated from oxidation/reduction potential changes.

Inhibition of Pitting Corrosion of Copper Tubes in Wet Sprinkler Systems by Sodium Sulfite (아황산나트륨을 이용한 스프링클러 동배관 공식 부식 방지)

  • Suh, Sang Hee;Suh, Youngjoon;Kwon, HyukSang
    • Corrosion Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.265-272
    • /
    • 2017
  • Inhibition of pitting corrosion of the copper sprinkler tubes by removing dissolved oxygen in water with sodium sulfite was studied on the wet sprinkler systems operated in 258 household sites. First, air in the sprinkler tubing was removed by vacuum pumping. The tube was then filled with sodium sulfite dissolved in water. Sodium sulfite was very effective in maintaining a very low dissolved oxygen concentration in water in the sprinkler tube for the observation period of six months. Water leakage from the copper sprinkler tube was reduced significantly by using sodium sulfite. Both pitting corrosion process and pitting corrosion inhibition mechanism were investigated by examining microscopical and structural aspects of corrosion pits formed in failed copper sprinkler tube. Pitting corrosion was caused by pressurized air as well as sediments such as sand particles in copper tubes through oxygen concentration cells. It was confirmed microscopically that growth of corrosion pits was stopped by reducing dissolved oxygen concentration to a very level by using sodium sulfite.