• Title/Summary/Keyword: Dissolved Gas

Search Result 373, Processing Time 0.028 seconds

Development of Artificial Diagnosis Algorithm for Dissolved Gas Analysis of Power Transformer (전력용 변압기의 유중가스 해석을 위한 지능형 진단 알고리즘 개발)

  • Lim, Jae-Yoon;Lee, Dae-Jong;Lee, Jong-Pil;Ji, Pyeong-Shik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.75-83
    • /
    • 2007
  • IEC code based decision nile have been widely applied to detect incipient faults in power transformers. However, this method has a drawback to achieve the diagnosis with accuracy without experienced experts. In order to resolve this problem, we propose an artificial diagnosis algorithm to detect faults of power transformers using Self-Organizing Feature Map(SOM). The proposed method has two stages such as model construction and diagnostic procedure. First, faulty model is constructed by feature maps obtained by unsupervised learning for training data. And then, diagnosis is performed by compare feature map with it obtained for test data. Also the proposed method usぉms the possibility and degree of aging as well as the fault occurred in transformer by clustering and distance measure schemes. To demonstrate the validity of proposed method, various experiments are unformed and their results are presented.

Gas Migration in Low- and Intermediate-Level Waste (LILW) Disposal Facility in Korea (중·저준위 방사성폐기물 처분시설 폐쇄후 기체이동)

  • Ha, Jaechul;Lee, Jeong-Hwan;Jung, Haeryong;Kim, Juyub;Kim, Juyoul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.267-274
    • /
    • 2014
  • The first Low- and Intermediate-Level Waste (LILW) disposal facility with 6 silos has been constructed in granite host rock saturated with groundwater in Korea. A two-dimensional numerical modeling on gas migration was carried out using TOUGH2 with EOS5 module in the disposal facility. Laboratory-scale experiments were also performed to measure the important properties of silo concrete related with gas migration. The gas entry pressure and relative gas permeability of the concrete was determined to be $0.97{\pm}0.15bar$ and $2.44{\times}10^{-17}m^2$, respectively. The results of the numerical modeling showed that hydrogen gas generated from radioactive wastes was dissolved in groundwater and migrated to biosphere as an aqueous phase. Only a small portion of hydrogen appeared as a gas phase after 1,000 years of gas generation. The results strongly suggested that hydrogen gas does not accumulate inside the disposal facility as a gas phase. Therefore, it is expected that there would be no harmful effects on the integrity of the silo concrete due to gas generation.

Enhance of Dissolved Oxygen Rate using a 3-prong Nozzle (3구 노즐을 이용한 산소의 용존율 향상)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.947-954
    • /
    • 2015
  • Dielectric barrier discharge plasma is a new technique in water pollutant degradation, which that is characterized by the production of chemically active species such as hydroxyl radicals, ozone, hydrogen peroxide, etc. If dissolving of plasma gas generated in the plasma reaction has increased, it is possible to increase the contaminant removal capacity. In this study, the improvement on the dissolving performance of plasma gas was evaluated by the indirect method measuring the overall oxygen transfer coefficient. Experiments were conducted to examine the effects of nozzle type, distance from water surface, air supply rate and liquid circulation rate. The experimental results showed that the $K_{La}$ value of the 3-prong nozzle is 2.67 times higher than the diffuser. The order of $K_{La}$ value with nozzle type ranked in the following order: 3-prong nozzle (inner diameter, less 1 mm) > circular nozzle (inner diameter, 1.5 mm) > ellipse nozzle (short diameter 1 mm, long diameter 2.5 mm) > circular nozzle (inner diameter, 3 mm). Optimal liquid circulation rate was appeared to be 1.7 L/min, the value of $K_{La}$ was 0.510 1/min. The value of $K_{La}$ with increasing air supply rate was revealed in the form of an exponential such as $K_{La}=0.3581e^{0.2919^*air\;flow\;rate}$.

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (I). Continuous-Automated Determination of Nitrite Ion Using Tubular PVC Membrane Type of pH Electrode (용해기체 분석용 기체 감응막 이온선택성 전극 (제 1 보). 관형 PVC 막 pH 전극을 이용한 아질산이온의 연속·자동화 정량)

  • Heung Lark Lee;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.388-398
    • /
    • 1989
  • A continuous-automated method for the determination of nitrite ion using gas-sensing membrane electrode was developed. The pH electrode of tubular PVC membrane type was used as a detector of this system. The slope of linear response of the electrode measured at optimum conditions for the continuous-automated determination of nitrite ion was 63.5 mV/decade. The concentration range of linear response and detection limit were 2.5 ${\times}10^{-4}{\sim}\;7.5{\times}10^{-2}$M and $8.0{\times}10^{-5}$M, respectively. This detection system was not only less interfering to acidic gas species than other methods but also less time consumable for determination.

  • PDF

A study on the effect of additives in insulating oil under uniform electric field (평등전계중의 절연유에 미치는 첨가물의 영향)

  • 국상훈
    • 전기의세계
    • /
    • v.30 no.6
    • /
    • pp.357-365
    • /
    • 1981
  • When electronegative gas SF$_{6}$ is dissolved and charged with insulating oil, the effect caused in the process by electronegative characteristic is studied and also the pressure effect caused by electronegative SF$_{6}$ acting on the liquid-level is examined respectively. When inert gas Ar is used to find a pressure effect acting on the liquid-level, its effect on dielectric strength is considered in the experiment. With three kinds of impulse voltage different in the duration of wave front and wave tail, a brief experiment if carried out ot see the effects on the dielectric breakdown characteristic as the wave is changing; either if I$_{2}$ and SF$_{6}$ are added to the insulating oil, or if the oil pressure is increased by Ar the dielectric strength becomes great and the longer the duration of wave front is, the greater the increase of the breakdown voltage, because I$_{2}$ added by a small quantity brings about some hirderance in the formation of gas phase. Likewise, the greater the changed pressure is, the greater the incerase of the breakdown voltage. When SF$_{6}$ is charged, the electronegative characteristic is prevailing at the time of low balanced pressure, and the pressure effect at the time of high balanced pressure.ressure.

  • PDF

Solid-Phase Extraction of L-Muscone from Aqueous Samples with Amberlite XAD-4 for Gas Chromatographic Assay

  • Paik, Man-Jeong;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.27 no.5
    • /
    • pp.539-543
    • /
    • 2004
  • An efficient analytical method was devised for the accurate L-muscone assay in aqueous samples. It involves solid-phase extraction of L-muscone in adsorption mode using XAD-4 as the sorbent and dichloromethane modified with 10% (v/v) methanol as the eluting solvent. The gas chromatographic analysis of the eluate residue dissolved in toluene on a DB-5MS capillary column provided complete resolution of L-muscone from the co-extracted interferences. The overall method showed excellent linearity ($r^2{\geq}$ 0.9994) in the range of 0.1 to 2.0 $\mu\textrm{g}$/mL with good intra- and inter-day precisions (% RSD = 2.5~7.3) and with high extraction recovery rates ($\geq$ 98.1 %). When the present method was applied to a L-muscone herbal drink product, the within-batch RE (%) in the labeled concentration (1.5 $\mu\textrm{g}$/mL) for the three randomly chosen bottles were -2.4, -1.3 and -3.3 with high precision (% RSD $\leq$ 3.1). The present method is considered to be suitable for quality control evaluation on liquid drinks and other complex formulations fortified with L-muscone.

Quantitative Analysis of Tiropramide in Human Blood by Gas Chromatography with Nitrogen-Phosphorus Detector

  • Kwon, Oh-Seung;Park, Young-Jin;Ryu, Jae-Chun;Chung, Youn-Bok
    • Archives of Pharmacal Research
    • /
    • v.26 no.5
    • /
    • pp.416-420
    • /
    • 2003
  • The analytical method of antispasmodic agent tiropramide {$(\pm)\alpha$-(benzoylamino)-4-[2-(diethylamino)ethoxy]-N,N-dipropylbenzenepropanamide hydrochloride} was developed by gas chromatography/nitrogen-phosphorus detector (GC/NPD) in human plasma. Two kinds of tiropramide tablets were orally administered to volunteers by Latin square crossover design, and blood was withdrawn as designed schedule. The plasma of 1 mL was loaded on Sep-pak $C_{18}$ cartridge and eluted with methanol after washing with 30% methanol. The residue dissolved in 100 $\mu$L of methanol after evaporation was analyzed by GC/NPD. Precision (CV%) of intra-day was located within 2.6% and accuracy was less than 9.7%. Inter-day precision was below 8.7% and accuracy was relatively good as less than 14%. Plasma samples obtained from human volunteers were analyzed for the determination of tiropramide concentration by using this method. The method was sensitive, rapid and suitable enough to be applied for pharmacokinetic and bioequivalence studies of tiropramide in human volunteers.

Simultaneous detection of five biocides in household products by gas chromatography-mass spectrometry

  • Choi, Kyeong-Yun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.197-204
    • /
    • 2022
  • A gas chromatography-mass spectrometric method was developed for determining 5-chloro-2-methyl-4-isothiazolin-3-one (CMIT), 2-methyl-4-isothiazolin-3-one (MIT), 1,2-benzisothiazolin-3-one (BIT), 3-iodo-2-propynyl butyl carbamic acid (IPBC) and benzoic acid (BA) in household products. A 0.5 g sample was placed in a test tube and dissolved with 5 mL water, 5 mL methylene chloride and 1.0 mL methanol. The solution was extracted by ultra-sonication followed by mechanical shaking using the salting out effect. Under the established condition, the lowest quantification limits of all analytes were in the range of 0.04-10 mg/kg and their relative standard deviations were less than 8.0 %. The method was used to analyze 10 household products. As a result of analyzing 10 household products, MIT was detected in the range of 1.2-3.5 mg/kg in 3 of 10 samples, CMIT was detected in the range of 2.6-8.2 mg/kg in 3 of 10 samples, and BA was detected in the range of 5.0-15 mg/kg in 4 of 10 samples. Meanwhile, BIT and IPBC were not detected in any of the products. It has been shown that this method can be used for the simultaneous determination of biocides with various physical and chemical properties in household products.

CO Fermentation of Eubacterium limosum KIST612

  • Chang, In-Seop;Kim, Do-Hee;Kim, Byung-Hong;Shin, Pyong-Kyun;Sung, Ha-Chin;Lovitt, Robert W.
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.2
    • /
    • pp.134-140
    • /
    • 1998
  • Eubacterium limosum KIST612 was cultured on phosphate-buffered basal medium (PBBM) with carbon monoxide (CO) as the sole energy and carbon source. The initial growth rate of this strain was approximately 0.17~0.25 $h^-1$/ and the $K_s$ value for dissolved substrate was 0.14 mM. CO was limiting during the growth of the bacterium when the CO partial pressure was less than 0.6 atm (0.5 mM dissolved CO). The bacterial growth rate was reduced in the presence of acetate. When sufficient CO was supplied using a gas-lift reactor, the acetate concentration went up to 90 mM in 116 h. Based on these findings, it is suggested that a pressurized reactor be used to develop a process to convert CO-rich gases into multi-carbon compounds.

  • PDF

Effects of Oxidation Reduction Potential and Organic Compounds on Anammox Reaction in Batch Cultures

  • Viet, Truong Nguyen;Behera, Shishir Kumar;Kim, Ji-Won;Park, Hung-Suck
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.210-215
    • /
    • 2008
  • The present study investigates the effect of oxidation-reduction potential (ORP) and organic compounds on specific anaerobic ammonium oxidation activity (SAA) using batch experiments. The batch tests were based on the measurement of nitrogen gas production. The relationship between ORP and dissolved oxygen (DO) concentration was found to be ORP (mV) = 160.38 + 68 log [$O_2$], where [$O_2$] is the DO concentration in mg/L. The linear relationship obtained between ORP and SAA ($R^2$ = 0.99) clearly demonstrated that ORP can be employed as an operational parameter in the Anammox process. At ORP value of -110 mV, the SAA was $0.272{\pm}0.03\;g\;N_2-N\;(g\;VSS)^{-1}\;d^{-1}$. The investigation also revealed inhibitory effect of glucose on the SAA while acetate concentration up to 640 mg COD/L (corresponding to 10 mM) had stimulating effect on the SAA. However, acetate concentration beyond 640 mg COD/L had inhibitory effect on the Anammox activity. The results indicated that nitrogen rich wastewaters containing low level organic matter could be better treated by Anammox microorganisms in real-world conditions after some acidification process.